Skip to content
naulon
Not checkedNot checked for notices yet.

Cause analysis of vibration in shell-and-tube heat exchanger

Wu Jia, Hu Jiansheng, Du Bin and 2 more

MATEC Web of Conferences · 2021

doi:10.1051/matecconf/202135301002 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Heat exchanger is a universal process equipment, which is widely used in chemical industry, oil refining, thermal power and other industries. Shell-and-tube heat exchangers often fail prematurely due to flow-induced vibration. In this paper, aiming at the problem of severe vibration of shell-and-tube heat exchanger in an enterprise, the vibration acceleration sensors are used to measure the vibration of shell and tube side of heat exchanger. Through the analysis of the measurement results, it is found that when the flow rate on the shell side of the heat exchanger is greater than 50000 Nm 3 /h, the flow-induced vibration of the tube bundle occurs, and the vibration frequency is 57Hz, which is close to the natural frequency of the tube bundle. And the greater the flow rate on the shell side, the more intense the vibration. In order to reduce the vibration of heat exchanger, the damping measure of inserting baffles between tubes is adopted.

Abstract licence: CC BY

References16

    16 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.