Skip to content
naulon
Not checkedNot checked for notices yet.

Calculation and reliability of timber structure bolt connection subjected to double unequal shears with thick plates as outer members

Musilek Josef, Podolka Luboš

MATEC Web of Conferences · 2017

doi:10.1051/matecconf/20179301005 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

The paper shows the calculation and reliability assessment of bolted connections subjected to unequal double shear with thick plates as outer members and inner timber member. This situation can occur very often during the designing of the timber structure bolt connection. Bolted connections subjected to unequal double shear are not described in present European standards where there is described only calculation and reliability of timber structure bolt connection subjected to double equal shears. So structure engineers have no rules which help them during a designing process when they are confronted with this case. The concrete example for the case of unequal shears is calculated and explained.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.