Mechanical response of local rapid cooling by spray water on constrained steel frame structure at high temperature in fire
Xia Yunchun
MATEC Web of Conferences · 2015
doi:10.1051/matecconf/20153501007 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Locally rapid cooling of spray water had strong impact on high temperature steel structure. When temperature of beam reached 600°C and cooling rate was more than 20°C/s, the maximum axial tension could reach more than 5 times of the originally compressive force. The compressive bending moment at joint of beam-to-column changed to tensile bending moment, and the maximum bending moment could reach above 4 times as that when heated. After rapid cooling by spray water, deflection at mid-span increased slightly.