Enhancement of AC high voltage measurements’ uncertainty using a high voltage divider calibration method
El-Rifaie Ali M., Mageed Hala M. Abdel, Aladdin Omar M.
International Journal of Metrology and Quality Engineering · 2015
doi:10.1051/ijmqe/2015014 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
This paper discusses enhancing of the measurements’ uncertainty for AC high voltage up to 100 kV. This is achieved by using a high voltage divider calibration method. Voltage measurements have been carried out at the Egyptian national institute for standards (NIS), using a high voltage measuring system (Phenix-KVM100), that consists of a high voltage divider and a voltage display. The voltage divider and display have been calibrated in low and high voltage ranges. Reference standard digital voltmeter and a multifunction calibrator have been used to calibrate the KVM100 for achieving accurate and traceable results. All calibrations have been performed automatically using Laboratory Virtual Instrument Engineering Workbench (LabVIEW) programs specially designed for this task. Uncertainty budget has been evaluated to get the measurements’ expanded uncertainties.
Abstract licence: CC BY
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.