An algorithm to calculate feasible operating conditions of electrical network, given overhead conductor temperature and sag constraints

Popova Yekaterina, Voitov Oleg, Semenova Lyudmila

E3S Web of Conferences · 2018

doi:10.1051/e3sconf/20185802015 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

The paper presents an algorithm to calculate feasible steady-state conditions of an electrical network. A distinctive feature of the calculation is the consideration of constraints on the temperature of bare conductor and the clearance of a controlled span of overhead line. This consideration is based on forming and solving an equation of conductor heat balance to calculate the conductor temperature depending on the current flowing through the conductor and environmental factors, including the actual values of air pressure and air temperature. The paper presents the results of numerical calculations performed for individual overhead lines and for a test 16-node scheme of electrical network. The results illustrate the algorithm performance and the importance of considering the above constraints.

Abstract licence: CC BY