Introduction
Volume electron microscopy (vEM; also referred to as volume EM) describes a set of high-resolution imaging techniques used in biomedical research to reveal the 3D structure of cells, tissues and small model organisms at nanometre resolution. vEM techniques leverage the unique ability of electron microscopes to reveal the structure of cells and tissues with the contrast and resolution to distinguish cell membranes and membrane bilayers. In the context of this Primer, and to delineate boundaries with other fields, we consider vEM to include any method of generating serial images in an electron microscope from resin-embedded cells and tissues with a continuous depth greater than 1 μm. This includes techniques based on transmission electron microscopy (TEM), in which the electron beam passes through an ultra-thin slice of the sample to generate an image, and scanning electron microscopy (SEM), in which the electron beam is raster-scanned over the surface of a sample generating an image from secondary and/or backscattered electrons. TEM-based vEM techniques such as serial section TEM (ssTEM) and serial section electron tomography (ssET) and SEM-based vEM techniques such as array tomography, serial blockface SEM (SBF-SEM; also known as SBEM) and focused ion beam SEM (FIB-SEM) all generate a series of images that can be stacked to form a 3D digital representation of the original sample volume. Further, we cover emerging vEM technologies such as automated serial TEM (TEMCA and GridTape TEM), fast ion beam technologies (plasma and gas cluster ion beam systems) and massively parallel imaging in SEM (multibeam SEM (mSEM) and FAST-EM).
vEM techniques have emerged over the past 20 years, largely in response to the demands of the connectomics field. Connectomics has the dual challenge of imaging neurons in the brain with sufficient volume to capture their length and with sufficient resolution to image individual synapses, as structural indicators of functional connections between cells. The development of vEM was enabled by key technological advances in sample preparation, in automation of sample sectioning and TEM and SEM sources and detectors and, importantly, in scientific computing to facilitate acquisition and analysis of large image datasets. The biomedical applications of vEM quickly moved beyond connectomics, as the value of imaging complex biological processes in 3D in tissues and model organisms became clear. vEM is now widely used in studies of cell structure and non-brain tissue in fields as diverse as infection, immunity, cancer research, neurodegeneration, developmental biology, plant biology, synthetic biology, biomechanics, biomaterials and clinical research.
Scientists who develop and use vEM technology come from a wide variety of research disciplines. At first glance, it would seem to be difficult to form a coherent community from such a diverse group. However, over the past decade, grassroots initiatives have gathered technologists, microscopists, computational scientists, biologists and clinical scientists together to drive the development and application of vEM. The European Molecular Biology Organization (EMBO) and microscope manufacturers have been particularly active in supporting the organization of workshops and symposia, and more recently the community has self-organized around a set of working groups to collaborate globally on vEM research, development and application (see the volume EM community website).
In this Primer, we present the state of the art and future perspectives for new audiences who wish to leverage the power of vEM in their own research. We outline the principles and practical steps required to move from a living biological entity to an image volume representing the sample, covering sample preparation and imaging using a range of vEM modalities (Experimentation), consider how to handle and analyse the massive amounts of image data produced by vEM (Results) and illustrate how vEM is used in real-world research, revealing structure and function across scales from organelles to organisms (Applications). Limits to the throughput of vEM and the importance of sharing rich vEM datasets (Reproducibility and data deposition) and how bottlenecks might be overcome (Limitations and optimizations) are discussed. Finally, we consider the challenges and opportunities of vEM for mining new understanding from complex multiscale biological systems (Outlook). Although we do not include electron microscopy techniques that generate serial images from frozen hydrated samples, such as cryo electron tomography or serial imaging in the cryo FIB-SEM, we address the exciting and challenging crossover between the worlds of vEM and cryo electron microscopy (cryo-EM) in the final section of the primer.
Experimentation
A vEM experiment encompasses multiple steps (Fig.1), each of which must be carefully planned to maximize the chances of a successful outcome (Box 1). Steps to be decided on and optimized include the choice of biological sample and experimental conditions, considering that the number of replicates is limited by the complexity and throughput of the technique; the probes that will be used to mark the region of interest (ROI) within the sample and add molecular information to the ultrastructure; the sample preparation protocol(s) that will be used to preserve the sample as close to living state as possible whilst enhancing compatibility with electron imaging in a vacuum; the strategy for tracking and trimming the sample to the ROI for imaging; the choice of vEM imaging modality, considering the desired field of view and resolution of the image data; and the size and complexity of the data analysis task with respect to producing a useful biological interpretation of the results.
Sample preparation
In this primer, we refer to the initial biological material as the sample, and the prepared material that is ready for imaging as the specimen (Fig.1). Almost any biological sample can be imaged using vEM, from prokaryotic cells through to eukaryotic cells, tissues and model organisms, although the volume and resolution dictates how much of a sample can be imaged. vEM of biological samples is underpinned by extensive optimization of sample preparation. A successful experiment relies on protocols that ensure the sample is kept as close as possible to its native state but also in a form that can be imaged. The specimen must be able to withstand the vacuum inside the electron microscope, as well as the high energy and current of the electron and/or ion beam; to deliver sufficient image contrast; and to exhibit sufficient structural rigidity, especially for volume slicing. Protocols are often tweaked to account for the properties of each sample, target structure and imaging modality, and thus are highly variable within the community. We give a generalised overview of sample preparation below, covering optimization of the sample size, fixing the sample, staining with contrast dyes, dehydrating the sample and embedding it into a resin, and trimming the resin block.
Optimization of sample size
The maximum sample size is dictated by the depth of penetration of fixatives and stains. It is generally recommended that the sample is less than 1 mm thick in at least one dimension, although the use of customised microwave ovens to increase the permeability of samples and the diffusion of solutions is pushing this limit. Cell monolayers present no issues, with a thickness of around ten microns when grown on glass or plastic, and cell suspensions can be centrifuged to a pellet of suitable size,. Model organisms in the millimetre range, like Caenorhabditis elegans,, Drosophila melanogaster and Danio rerio,, may be dissected or imaged in their entirety. Tissue in the centimetre range is usually dissected into smaller pieces or cut into slices using a vibratome, although mouse brain has been successfully processed intact for connectomics.
Fixation
Two avenues can be taken for fixation, depending on the sensitivity of the biological structure under investigation and the size of the sample. Chemical fixation using combinations of methanol-free (para)formaldehyde (2–4%) and glutaraldehyde (1–4%) is straightforward; however, this may not capture fast subcellular events such as membrane tubulation. Alternatively, cryo-fixation using high pressure freezing (combined with freeze substitution to transition the sample to resin) captures fast biological events occurring at the scale of milliseconds and minimizes shrinkage artefacts, although this method requires complex equipment –. The choice between chemical fixation and cryo-fixation is mostly determined by the initial size of the sample; high-pressure freezing is limited to samples with dimensions of approximately 200 μm, whereas millimetre-sized samples can be fixed through perfusion of chemical fixatives. As a result, cell monolayers, cell suspensions, C.elegans and D.melanogaster are particularly well suited to high-pressure freezing owing to their small size. Further detailed guidance on fixation choice is available elsewhere –,,,.
Contrasting
The addition of staining to enhance electron contrast of biological samples is a critical step in vEM to improve the visibility of membranes and make the sample conductive. The vEM imaging modality chosen influences the level of staining required: TEM-based techniques are compatible with lower contrast levels, partially owing to an improvement in detectors and because images are generated by scattering of primary electrons; ion beam techniques require medium levels of contrast because images are formed by backscattered electrons; and in situ microtome techniques require high levels of staining to reduce the beam dose required to generate a backscattered electron image to prevent charging artefacts and resin de-polymerization. Protocols used by the community are highly variable, but most involve immersion of the sample into solutions containing combinations of heavy metal salts to introduce contrast, including uranium, lanthanides, osmium (reduced or aqueous), thiocarbohydrazide, tannic acid and pyrogallol,. If an experiment can tolerate light staining, then uranium salts only may be used, but most samples require heavy staining with layers of reduced osmium, thiocarbohydrazide and osmium, followed by uranium salts and lead aspartate –. These modern protocol variations are all based on historical work –, with new variations optimized for specific sample types appearing regularly in the literature,,,. Furthermore, the use of uranium is prohibited in several countries, leading to the development of replacement compounds,.
Dehydration and resin embedding
To protect samples from the electron microscope vacuum and facilitate slicing of the sample into ultra-thin sections, water in the cells and tissues is removed by dehydration with a solvent that is compatible with subsequent liquid resin infiltration, which is then polymerised to form a hard block. Chemically fixed samples are dehydrated using a graded series of ethanol or acetone, whereas high pressure frozen samples are contrasted and dehydrated simultaneously during a process called freeze substitution,,. Following dehydration, a graded series of resins are used to infiltrate the sample before it is hardened using heat, or UV light,. Epoxy resins such as Durcupan, Spurrs, Epon 812 and Hard Plus are most commonly used due to their good sample penetration properties and stability during imaging. Methacrylate resins such as Lowicryl HM20 and LR White may also be used, particularly when preserving the emission of fluorescent proteins in the sample.
Trimming
To prepare the sample for ultra-thin sectioning or milling, and to optimize its volume to the downstream imaging modality being used, the sample is manually trimmed using a razor blade or diamond knife in an ultramicrotome. Many samples require prior knowledge of the position of the target structure to guide trimming, which is usually achieved by integrating fluorescence microscopy and/or X-ray microscopy (Box 2) into a correlative workflow in order to locate and follow the target structure during trimming,,-. Once trimmed, specimens may be mounted directly for vEM, or cut into ultra-thin sections using a diamond knife, depending on the downstream imaging modality. Removal of excess resin before polymerization –, or use of a conductive coating can minimize trimming and facilitate targeting of biological structures by revealing surface anatomy. Large resin-embedded tissue samples may also be subdivided using a hot knife for vEM of serial slabs,.
Probes
vEM techniques provide an opportunity to correlate morphological data with molecular characterization. The ideal labelling method for vEM should enable molecular localization throughout the depth of the sample, providing molecular resolution with the sensitivity to detect molecules at endogenous levels in their native non-perturbed environment. This is challenging but has been achieved through the development and application of a suite of genetically encoded tags.
Genetically encoded tags that produce electron-dense reaction products that are visible in vEM have been described, including metallothionein-based probes –, reASH, miniSOG and APEX/APEX2. Of these, APEX2 (an evolution of the original APEX probe that has higher activity in cells) is the most established tag. It is an ascorbate peroxidase that is active in both cytosolic and luminal/extracellular compartments, and is proving to be a robust method with a large number of applications including detection of directly tagged proteins of interest, nanobody-directed detection of GFP and RFP-tagged proteins and labelling of specific protein complexes using a split GFP-based method or split-APEX. APEX converts soluble diaminobenzidine (DAB) into an insoluble electron-dense reaction product. APEX can be used with chemically fixed specimens or in cryo-EM schemes (cryoAPEX) and has widespread applicability in both cell and tissue/animal systems, even enabling multiplexed labelling of different cell populations in tissue. The APEX-directed DAB reaction product can also nucleate the formation of gold colloids,, a method compatible with single-molecule detection as shown using genome-edited cells with tagged proteins at endogenous levels. Single molecule detection is also possible using an elegant technique based on a metallothionein tag that can be used to nucleate gold particles and, potentially, could have applications in different vEM modalities.
Fluorescent genetically encoded tags can also be used to locate structures in vEM, either indirectly or directly, using a range of correlative light and volume electron microscopy (vCLEM) workflows. In addition to genetically encoded tags, antibodies and neural tracers have been used to label organelles and cells for vEM. The recent development of a method for immunolabeling throughout larger volumes of tissue (sections up to 1 mm thick), without permeabilization, retains good ultrastructure and allows the collection of molecular information using vCLEM with SBF-SEM. Array tomography, allows labelling on sections, removing the limitation of depth penetration into hydrated tissue samples, but is dependent on the availability of electron microscopy-compatible antibodies and epitope preservation during sample preparation. Using a combination of neural tracers, expressed fluorescently-tagged proteins and on-section immunolabelling opens the possibility of multiplexed labelling in electron microscopy. Another strategy for multiplexed labelling with ssTEM is to pull out a few ultra-thin sections from the series, stain them using immunohistochemistry or immunogold labelling and, then, propagate the molecular information through the serial image stack.
TEM-based vEM
Volume imaging using TEM (Fig.2) combines the benefits of high resolution, non-destructive imaging with the speed of full-field (as opposed to scanning) acquisition using CCD or CMOS cameras. The geometry of the transmission electron microscope limits the size and thickness of the specimen that can be imaged so an ultramicrotome with a diamond knife is used to first cut the sample into serial ultra-thin sections, which are picked up on support grids 3 mm in diameter. For ssTEM, section thickness is generally between 50 and 100 nm. For ssET, slightly thicker sections of 200 to 300 nm are imaged, and resolution through the volume is increased by collecting a series of images at different tilt angles (usually ±70°), which are then reconstructed into a digital volume. To improve the reconstruction, dual tilts may be collected at 90° to each other. In both ssTEM and ssET, serial sections are imaged sequentially and the resulting images stacked to represent the sample volume.
ssTEM delivered the first of the whole model organism electron microscopy volumes in the Mind of the Worm, a map of the neural connectivity of C.elegans. ssET has also delivered insights into the complexity of subcellular structures,. However, these techniques are slow, low throughput, manual and technically challenging, severely limiting the volumes that can be imaged. Efforts to address these limitations in TEM-based vEM have focused on solving the dual challenges of the limited field of view imposed by commercial detectors and automation of section retrieval onto electron-transparent supports for imaging in transmission mode.
One of the first computational solutions for large-scale ssTEM imaging enabled the automated acquisition and assembly of thousands of individual images from each section into a large mosaic, to acquire a terabyte volume of rabbit retina. On the instrumentation side, a fruitful approach was the development of TEMCA, which used a commercial 120 keV TEM customised with an array of detectors combined into a single large sensor. The microscope was supported on a raised platform to increase the distance between the sample and the detector, thereby increasing the field of view. However, although detection was optimized, these approaches still relied on manual collection of thousands of sections onto classical TEM slot grids. This issue was partially addressed using an autoloader on the TEM, with which grid exchange was automated using a robot synchronized with the imaging process –. Grid handling was further improved by the development of GridTape TEM, (Supplementary Movie 1), in which sections were cut using a modified ultramicrotome for collection on a tape with electron transparent film-covered holes. The tape was fed through a modified sample holder on a customised transmission electron microscope, and each section automatically imaged using a fast array of detectors, enabling the motor control circuits in adult D. melanogaster to be mapped. In parallel, a second system called piTEAM has been developed, consisting of a parallelized array of transmission electron microscopes optimized for GridTape imaging. The speed, automation and non-destructive nature of GridTape TEM has the potential to transform peta-scale vEM imaging while, simultaneously, creating new challenges in data handling and analysis.
SEM-based vEM
Volume imaging using SEM (Fig.2) combines the benefits of large fields of view and a microscope chamber compatible with large specimen holders and in situ specimen slicing mechanisms. SEM-based vEM has been widely adopted and includes some of the most user-friendly vEM technology, allowing routine acquisition of large-volume image data with ultrastructural resolution,–. Three complementary but distinct approaches have been developed in parallel: those using in situ microtomes such as SBF-SEM; those using ion beams such as FIB, plasma FIB (pFIB) or enhanced FIB-SEM (eFIB-SEM), and array tomography,,. These three approaches all require heavily contrasted specimens; a scanning electron microscope optimized for low voltage imaging (1-2 keV) with a field emission gun and backscattered or secondary electron detectors; and dedicated software and a stable system for autonomous imaging over days, weeks or even months.
In situ microtomes
There are currently three commercial SBF-SEM (Fig.2 and Supplementary Movie 2) products available, to our knowledge - 3View (Gatan Inc., now part of Ametek Inc.), VolumeScope (ThermoFisher Scientific Inc.) and Katana (ConnectomX Ltd) - as well as several home-made solutions. All rely on the same principle - a diamond knife held in a miniaturised ultramicrotome mounted in the SEM chamber moves back and forth across the resin block, with the block moving upwards in z in incremental steps that determine the section thickness,. In all solutions, image tiling is possible by moving the entire microtome in the chamber. This technique has the advantage of imaging large volumes, but the disadvantage of suboptimal working distance, restricting resolution and choice of detector. Charging artefacts caused by poor conductivity of the sample blocks are a common problem. The first versions of in situ microtomes relied on variable pressure in SEM to mitigate charging, which is a particular problem for specimens that contain large areas of non-conductive empty resin such as cell pellets or lung tissue. Now, newer instruments use a focal charge compensation system to inject a gas flow locally at the level of the blockface to mitigate charging, increasing the range of specimens that can be imaged.
Ion beams
Alongside the development of in situ microtomes, researchers and manufacturers explored the usage of a gallium FIB to remove thin sections from resin blocks inside a scanning electron microscope – (Fig.2 and Supplementary Movie 2) By replacing mechanical sectioning with electronically controlled ion milling, this technique has the advantage of shaving thinner slices than in situ microtomes (typically 50 nm for in situ microtomes versus 5 nm for FIB-SEM) and achieves higher resolution with a better signal-to-noise ratio. The possibility of obtaining isotropic voxels, where the slice thickness in z matches the pixel size in XY, makes FIB-SEM attractive for automatic segmentation. Uniquely, the direction of ion beam milling is perpendicular to that of other sectioning techniques, an important point to consider during experimental design, to ensure that the region to be imaged is accessible to the electron beam. However, the ion beam loses energy as it progressively mills down the blockface, limiting the depth that can be precisely cut. In order to improve speed and throughput, specimens have been imaged in parallel on multiple eFIB-SEM instruments that are more stable and resilient to errors over imaging runs of many months. As negative charges imparted to the imaged surface by the electron beam are mitigated by subsequent exposure to positive ions from the milling beam (and concomitant removal of this charged slice), FIB-SEM can be used to image poorly contrasted specimens in which the emission of fluorescent proteins has been preserved. Recently, pFIB instruments with other ion species have been used for milling biological specimens, including oxygen, xenon and argon,, which may offer finer or faster milling than gallium. Newer instruments use oxygen plasma, gas cluster ion beams and multi-ion species to increase the milling speed and surface area.
Array tomography
Whereas in situ microtomes and ion beams both work by iterative imaging of the blockface, array tomography is based on SEM imaging of pre-cut ultra-thin serial sections arranged in two dimensions on a solid substrate (Fig.2 and Supplementary Movie 1). Serial sections are often obtained using a standard ultramicrotome and collected on either silicon wafers,, or carbon-coated or indium tin oxide-coated glass coverslips,. Manual section pickup is challenging, requiring advanced expertise and manual dexterity, and is commonly used for smaller numbers of serial sections (< 500). To overcome this limitation, various automated or semi-automated methods have been developed, including the Artos 3D (Leica Microsystems), the ASH-100 and ASH2 (RMC Boeckeler), fishing, MagC, a modified knife, AutoCUTS SEM and the Arraybot. An alternative and reliable approach for producing large numbers of serial sections is the automated tape-collecting ultramicrotome (ATUM). This system, as the name implies, collects the serial sections on tape, which is then mounted on wafers for imaging. Commercial solutions for array tomography are becoming more widely available, mainly facilitated by advances in software automation for serial imaging. For imaging large volumes, mSEM and FAST-EM offer fast imaging at nanometre resolution by splitting the electron beam into multiple beamlets that image the sample in parallel –. Compared to in situ microtomes and ion beams, array tomography has a lower z-resolution (a minimum of 30 nm). However, because this approach preserves the sections, it has the advantage that the specimen can be re-imaged in different areas or at different magnifications. Furthermore, the sections can be imaged at the light level prior to electron microscopy, to collect molecular information from immunofluorescence, neural tracers or genetically encoded probes,,,. Integrated light and scanning electron microscopes are a promising solution for efficient acquisition and registration of fluorescence microscopy and electron microscopy images from array tomography specimens,,.
Multi-vEM workflows
The research question, sample size and target feature may dictate a multiscale, multi-resolution workflow (Fig.3). In these circumstances, a multi-vEM approach is very powerful. For example, SBF-SEM can be used as a smart trimming tool to locate smaller regions for higher resolution imaging using FIB-SEM,, TEM or spatial compositional analysis using nanoSIMS. Other hybrid approaches have focused on the combination of thick serial sectioning and FIB-SEM to rapidly screen large volumes with acquisition of high-resolution isotropic information for targeted sub-volumes,.
vCLEM
Correlative microscopy techniques are an essential part of most vEM workflows, because the volume that can be imaged in electron microscopy is so much smaller than the size of most biological samples. vCLEM may be used to target and track a structure between two imaging modalities, or may be used to localise molecules to structures within the volume, providing clues to their function (Fig.4).
vCLEM for tracking at the single-cell level tends to rely on external coordinate systems such as gridded coverslips for coarse targeting, At the tissue scale, the problem becomes more complex because of the sheer volume of the sample compared to the size of the target structure, and workflows often rely on anatomical features such as blood vessels as landmarks for correlation,–. One option that has been employed to great effect in large specimens is the use of high-power lasers for branding marks within the specimen or on the resin block, laying a trail of breadcrumbs to individual cells and features of interest,,,–.
vCLEM for molecular localization uses high-resolution correlation to overlay fluorescent microscopy images of fluorescent proteins acquired post embedding with electron microscopy images for function-structure studies. Methods have been developed that allow retention of the fluorescence of proteins after resin embedding, delivering accurate correlation of fluorescence to ultrastructure,,–. The discovery that fluorescent proteins showed blinking properties within the low-vacuum environment of SEM has allowed molecular localization at super-resolution scales. A recent study has carefully optimised the use of in-resin fluorescence, resulting in a complete and robust workflow for vCLEM. A special case of vCLEM is correlative array tomography –,,, where molecular information from antibody immunolabeling, fluorescent proteins or neural tracers is acquired from the same ultra-thin sections as imaged using electron microscopy, thus facilitating registration of the different modalities and enabling multiplexed molecular labelling.
Data acquisition
All commercial electron microscopes are bundled with proprietary acquisition control software that allows users to set parameters and manually acquire images. Parameters to be optimized include voltage, probe current, field of view, pixel size, slice thickness, dwell time and exposure (depending on the imaging modality used). For vEM, additional software is needed to manage the acquisition workflow and drive the stage, the ultramicrotome or the ion beam, for example, DigitalMicrograph (3View, Ametek Inc.), Maps (VolumeScope, ThermoFisher), Atlas 5 (Zeiss) and custom software with a tablet interface (Katana; ConnectomX). To extend the capabilities of commercial software and offer more flexibility, control, specialized features and ease of use, several open-source solutions have been developed. The earliest example is SerialEM, an acquisition control software developed to perform automated electron tomography with tilt series. WaferMapper is a MATLAB software package that automates image acquisition from sections collected on wafers for array tomography. SBEMimage is an open-source Python application designed to control complex image acquisition workflows with SBF-SEM and array tomography. piTEAM enables large-scale TEMCA image acquisitions, with core components controlling the microscope(s), a web-based graphical user interface, and a graphics processing unit-based image processing pipeline. Automated targeting of regions of interest for FIB-SEM can be achieved with CLEMSite.
Data processing
Data processing in vEM tends to be customized into application-specific pipelines, lifting modular components from different software platforms.
Volume reconstruction
After image acquisition, the series of individual images must be reconstructed into an image volume. This step may include alignment of serial images within a single volume, and subsequent stitching together of multiple image volumes, depending on the size of the original sample. Alignment of adjacent images should recover continuity across the image volume and retain the geometrical properties of the original sample, despite distortions that may occur during sample preparation and image acquisition. Cross correlation, and Scale Invariant Feature Transform (SIFT) are commonly used techniques for the detection, characterization and matching of local features in image series. The SIFT concept was expanded to automatically register large image mosaics by globally minimizing the registration error, implemented as part of TrakEM2 in ImageJ/Fiji –. Another method called Alignment to Median Smoothed Template (AMST) was developed to align FIB-SEM datasets. Elaborating on sequential use of rigid and affine transformations, it has the advantage of correcting for local pixel size variations whilst preserving long-range alignment of structures. Following the general trend of exploiting deep learning for computer vision tasks, the largest currently available vEM volumes have been aligned through new learning-based procedures, combining defect detection, short-range and long-range alignment,. In current practice, machine learning techniques are not used for alignment. However, there is ongoing research implementing this as a strategy.
Image enhancement
vEM datasets can be notoriously challenging to analyse due to their high dimensionality, texture, variations in intensity within and across volumes, noise and resolution loss due to sampling. Image enhancements to improve contrast or noise characteristics may be applied to the serial images. Traditional methods may be used to reduce noise within an image, for example contrast limited adaptive histogram equalization (CLAHE), available as a standard image processing option in Fiji. Content-aware image restoration methods have also been applied to vEM data sets to improve the signal-to-noise ratio. In general, while supervised network training works well for SEM reconstruction, TEM data requires semi-supervised (Noise2Noise) or unsupervised (Noise2Void) training methods.
Multimodal registration
For vEM datasets collected as part of a correlative or multimodal workflow, an additional step is required to correlate the different datasets to each other. Here, we clarify correlation for relocation as the overlay of shared features or patterns between two or more imaging modalities, with the intention of targeting an ROI for imaging. On the other hand, correlation for registration is the accurate (and often computational) alignment of data sets from two or more modalities, with the aim of imaging cells or macromolecules that were preferentially labelled in a subset of the modalities. As an example, X-ray microscopy can reveal the position of a neuron or cell for downstream imaging by vEM, whereas overlay of fluorescence microscopy and vEM data sets acquired from the same volume can reveal the identity and ultrastructure of an organelle containing a fluorescently tagged molecule. Registration may also be used to align image volumes from different specimens from a population to create an average atlas of ultrastructure of a model organism,.
To register multimodal data, a fiducial of some sort is required. Fiducials are often specific to - and constrained by - the sample type and biological question. With array tomography datasets, where different modalities come from the same ultra-thin sections, registration of fluorescence microscopy and vEM can be done with high precision in 2D, and thus in 3D, and cell nuclei are often used as fiducials. In vCLEM studies, mitochondria, and nuclei are popular internal fiducials, as they are easily labelled with chemical dyes or fluorescent proteins and can generally be recognized in EM images by their morphology. Software packages such as 3D slicer, eC-CLEM, BigWarp and elastix, offer varying degrees automation for multimodal image alignment.
vEM image segmentation
Image segmentation - the detection and delineation of structures of interest - is required for extraction of quantitative information from rich vEM datasets. Non-discriminant contrast, diversity of appearance of structures, and large image volumes turn vEM segmentation into a highly non-trivial problem, where cutting-edge methods relying on state-of-the-art computer vision techniques are still far from reaching human parity in segmentation accuracy. Although significant progress has been made in recent years, largely due to the introduction of deep learning-based methods, there is not yet a single reliable and easy-to-use solution for fully automated segmentation of vEM images. Practitioners must choose between (or combine ) manual, semi-automated and fully automated solutions based on the difficulty of the segmentation problem, the data size and the computational expertise and resources of their team or institution. Furthermore, almost all automated solutions rely on machine learning and may require large amounts of example segmentations to train a model, although in some cases models trained for the same task on similar datasets are available and can be applied directly.
Manual and semi-automated segmentation
For small datasets, for subsets of large datasets, and for datasets in which only a few structures are to be analysed, manual or semi-automated approaches are often preferable. Here, ready-made solutions that do not require computational expertise or example segmentations are available. Open-source solutions exist: the ilastik carving workflow enables users to sequentially extract objects from a volume by labelling parts of the image that belong to the object and the background (everything else) and using a region growing algorithm for segmentation. Microscopy Image Browser (MIB) also contains a set of tools for semi-automatic segmentation based on thresholding, morphological image operations and region-growing. The software suite IMOD provides manual and semi-automatic drawing tools for tracing and refinement of organelles. Amira (ThermoFisher Scientific) and Imaris (Oxford Instruments) are commercial software packages that offer semi-automated segmentation combined with advanced visualization capabilities. The Fiji plugin TrakEM2, Reconstruct, Webknossos and VAST are also used. Note that these tools can often only load data up to a certain size. To overcome this limitation, one can downsample the data if the structures of interest are discernible at lower magnification, or crop regions of interest. Downsampling or cropping can be achieved with Fiji, for example using the BigDataProcesser plugin, or programmatically for even larger data using Dask or other libraries that provide easy access to task parallelization. These tools only support a certain set of image data formats. Bioformats, which is integrated within Fiji, can be used to convert between all common data formats.
Automated segmentation
If the data size exceeds the capabilities of semi-automatic segmentation, for example when structures of interest need to be fully and densely segmented in a large volume, fully automated methods must be employed. These methods are almost universally based on machine learning: they use example data in the form of ground-truth segmentations to estimate parameter values for the segmentation model, which can range from a simple classifier (rarely used in vEM due to the complexity of the task) to a very deep neural network with millions of parameters. Initially, fully automated segmentation was developed for connectomics. This application requires the complete segmentation of neurons and synapses in large volumes and is thus only feasible with a high degree of automation. Development has been significantly advanced through open challenges (such as ISBI2012 ) leading to methods that enable circuit reconstruction for the brains of small organisms or brain regions. Recently, large-scale segmentations have also been achieved in other domains such as cells and selected organelles in a complete small organism or many organelles in cells,.
Machine learning methods can be trained to produce different flavours of segmentation, labelling the pixels either by semantics (for example, label all mitochondria pixels as 1 and the rest as 0) or by the objects they belong to (for example, label all pixels of the first mitochondrion as 1, of the second mitochondrion as 2, of the nth mitochondrion as n, with non-mitochondrion pixels as 0). Furthermore, a semantic segmentation can be transformed into an object segmentation by connected component labelling or a watershed transform. This approach is often used for separated objects such as mitochondria or nuclei and can be found, for example, in the Fiji plugin MorphoLibJ. Alternatively, semantic segmentation can be used to predict boundaries between objects. The object segmentation is then achieved by a watershed transform or graph-based agglomeration. This approach, often used to segment cells or densely packed vesicles, is also available in MorphoLibJ or in the ilastik boundary-based segmentation workflow. Finally, methods that directly predict an object segmentation have now been introduced for light microscopy, and, very recently and only in the form of research code, for vEM data.
Generally, machine learning-based segmentation models can be divided into two categories: feature-based learning and deep learning. Feature-based learning methods use a set of predefined features (usually linear and non-linear image filters) as input to a non-linear classifier such as a support vector machine or a random forest that outputs the (semantic) segmentation. They need few examples and are available via user-friendly tools. Methods using deep learning do not rely on pre-computed features but, instead, learn features and segmentation jointly. They can solve more difficult segmentation problems, but their superior accuracy requires much larger amounts of examples, and the training must be performed on graphics processing units. The U-Net is a widely used deep learning model architecture for segmentation in vEM, employed as a backbone in most state-of-the-art segmentation methods (Fig.5).
Feature-based segmentation methods can be trained interactively from brush-stroke annotations and are implemented in user-friendly tools such as the ilastik pixel classification and autocontext workflows and the Fiji Weka plugin. Training deep learning models is more challenging than feature-based models, as these require significantly more training data, computational expertise and resources. Consequently, most user-friendly tools delegate the training step to method developers and implement prediction with pretrained models for end users. These tools include DeepImageJ, the ilastik neural network workflow, DeepMIB, CDeep3M, epanada and APEER (Zeiss). For successful application, the model needs to be trained on data very similar to the data at hand, preferably using generalizability-enhancing tricks such as data augmentation, while unsupervised pretraining on large unlabelled and heterogeneous datasets may increase model performance overall. All tools listed above provide a set of pretrained models and the recent Bioimage Model Zoo community project hosts models in a cross-compatible format that is currently supported by DeepImageJ, ilastik and ZeroCostDL4Mic. While some of these tools (CDeep3M, APEER) also implement network training, they do not eliminate the need for many segmentation examples and a graphics processing unit. Given these requirements, for practitioners with some computational expertise it may be easier to train a new model directly using Python scripts, which provides more flexibility. An intermediate solution is the use of prepared Jupyter notebooks such as those provided by ZeroCostDL4Mic that come with a running environment and use publicly available computational resources.
Efficient training and post-processing procedures for deep learning methods constitute an active area of research. Most of these methods are made available as Python code using one of the most popular deep learning frameworks (PyTorch or TensorFlow), and they can be retrained, extended and applied through programming in Python. Mala, MWS and SegEM were originally developed to segment neurons but can be used for other segmentation tasks as long as objects have discernible boundaries. The approach of flood filling networks has been used for many large-scale connectomics segmentations,, and synapse detection and synapse partner prediction tasks,. Training deep learning methods for new data requires many segmentation examples; large and heterogenous training datasets may produce more generalist models. These examples can be generated using the manual/semi-automated tools introduced earlier or more general-purpose annotation tools such as napari and Fiji plugins (like LabKit). Alternatively, proofreading tools can be used to correct an initial segmentation, for example FlyWire, Paintera or Dojo. These tools enable faster generation of examples, but generally have a steeper learning curve and less documentation. They can also be used to correct errors in the final segmentation results.
Although the methods listed above can be wrapped in scripts and notebooks to be made accessible to practitioners of limited computational experience, application of these methods to large data sets, from tens of gigabytes to hundreds of terabytes, requires significant computational resources and experience with large-scale distributed computing. For such teams, open-source solutions for large-scale deployment exist and can be freely exploited,–.
Commercial solutions and crowdsourcing
If the segmentation problem at hand is not feasible with the tools introduced above, for example owing to missing pre-trained models or lack of computational expertise, the task can also be out-sourced to companies offering segmentation as a service, for example scalable minds or ariadne.ai. For large projects, crowdsourcing of the segmentation effort is also an option, which has successfully been pioneered for segmenting retinal neurons as well as cells and organelles, and is currently underway for neurons in the fruit fly brain.
Examples of image segmentation workflows
Associated with this Primer, we provide two example data analysis workflows for neuron and mitochondria segmentation. The first example demonstrates how to use a pretrained network for neuron boundary segmentation in ilastik, followed by graph-based post-processing to obtain an instance segmentation. The second example demonstrates mitochondria segmentation for a large electron microscopy volume using a pretrained network and Python libraries. For both examples, alternative approaches are sketched.
Data exploration and visualization
Interactive visualization of large vEM datasets is challenging. Important features for visualization software are the ability to view the data from arbitrary (non-axis-aligned) angles, surface mesh rendering for displaying segmentation results, and support for viewing large datasets. Many of the software platforms already mentioned provide options for data visualization and exploration, including Fiji, napari, IMOD and MIB. However, exploration of very large datasets is not possible with many visualization tools, because they rely on loading all data into memory or only provide inefficient access to data out of memory. To overcome these limitations, support for chunk-based data access and a precomputed multi-scale image pyramid format is necessary and is offered by some microscopy vendors. In addition, support for on-demand access of data stored in the cloud is desirable. In Fiji, the BigDataViewer and MoBIE, plugins can be used for exploring large data. For collaborative skeleton tracing and connectome analysis, Catmaid, Neuroglancer and tools from the Knossos family (Knossos, pyKnossos and webKnossos ) provide similar functionality and extend support to collaborative annotation for volumetric segmentation.
Applications
Conventional 2D imaging with TEM requires the trained eye of an expert to interpret the intricate topology of organelles within the crowded environment of a cell. A particularly elegant, and accurate, interpretation of the sarcoplasmic reticulum was made by Porter and Palade in 1957. In this section, we have selected a few examples to illustrate the breadth of vEM applications following a scale logic, from single organelles through to cell-cell interactions, small organisms, and tissues. We do not include applications in the physical sciences, but it should be noted that FIB-SEM techniques, in particular, are commonly used in the semiconductor and materials sciences. This list of applications is far from being exhaustive, and we encourage readers to perform literature searches to find examples of vEM data representing their own organelles, cells and tissues in this fast-evolving field.
The cytoskeleton
Most cytoskeletal elements and organelles span greater distances than the typical thickness of a TEM section (30 to 100 nm), and therefore require vEM to be seen in their entirety (Fig.6). Yet, they are usually challenging to detect by electron microscopy as their cross-sectional dimensions are often close to the minimum pixel size of the given acquisition technique. Microtubule spindles, for example, have been reconstructed using ssTEM tomography at sufficient resolution to count microtubules, measure their length and visualize how they interact with the kinetochore (resolution of 2.3 nm). However, the acquisition and processing of serial tomograms, and, most importantly, the segmentation of individual microtubules, represent a major effort that very few laboratories have undertaken to date. More recently, state of the art FIB-SEM data at 4 nm isotropic resolution have reaffirmed the extent of single microtubules in cultured cells and pancreatic β-cells, illustrating how microtubules connect with multiple organelles.
Secretory organelles
Organelles of the secretory pathway have been studied in 3D with many vEM techniques. The complex architecture and connectivity of stacked endoplasmic reticulum sheets in rodent neuronal and secretory cells was unravelled by Terasaki et al. using array tomography. Importantly, the section thickness (30-40 nm) was set to be lower than the ER lumen diameter and the inter-stack spacing. The changing morphology of the endoplasmic reticulum during cell division was studied by ssET and SBF-SEM, with or without electron-dense DAB labelling of the ER lumen,. Further endoplasmic reticulum studies drove the introduction of image analysis tools to capture and model the complexity of the organelle,, including a description of the curvature landscape that defines the various endoplasmic reticulum sub-compartments in cultured cells. The endoplasmic reticulum morphology of specialized cells such as neurons has also been investigated by SBF-SEM and FIB-SEM, and studies of endoplasmic reticulum exit sites using FIB-SEM unravelled the tubular (rather than vesicular) nature of this intermediate compartment in insect and mammalian cells.
Further down the secretory pathway is the Golgi, the complexity of which justifies the need for 3D visualization. In the early 2000s, a detailed description of the Golgi complex visualised by ssET was published. ssET is still the method of choice to study this organelle as the distance between cisternae in a stack requires high-resolution imaging. More recent studies capitalized on the larger acquisition volumes offered by FIB-SEM to capture the full stretch of the Golgi ribbon,. Further, the endo/lysosomal pathway has been extensively imaged by vEM, using vCLEM to assign molecular identity to otherwise ambiguously shaped structures,.
Other subcellular components
vEM has made significant contributions to the study of inter-organelle interactions, identified by spatial proximity (< 20 to 30 nm) between the limiting membranes of two organelles. In cultured cells, and liver tissue, FIB-SEM has shown changes in organelle morphologies associated with changing physiological states. vEM is also the technique of choice to describe the complexity of pathogen-induced structures, such as virus replication organelles,– and membrane perturbations associated with viral budding in HIV and SARS-CoV-2 infected cells,–.
Cell-cell interaction in metazoans
At the cellular level of our scale logic, vEM workflows are ideally suited to studying the finer details of the complex interactions between individual cells and/or groups of cells. For instance, in Spongilla lacustris, a freshwater sponge, vCLEM was used with FIB-SEM to demonstrate that individual neuroid cells interact with multiple choanocytes, supporting a role in neuron-effector communication, and with their conserved genetic makeup, as putative neuronal ancestors. Using array tomography and SBF-SEM, fibre cells in the Placozoa Trichoplax adhaerens were shown to contact multiple adjacent cell types and display evidence of phagocytic activity, suggesting a macrophage-like role in innate immunity that appeared early in metazoan evolution. In symbiotic microalgae (the algal symbiont Phaeocystis cordata, in its acantharean host), reconstructions of FIB-SEM image series showed significant alterations in morphometric measures, reflecting interaction between the symbiont and controlling host. Similar approaches have also been used to examine conserved morphometric features in various phytoplankton, suggesting that topology could be modulated by energy-management constraints.
Host-pathogen interactions
vEM techniques are also very powerful for studying host-pathogen interactions. vCLEM studies combining fluorescence microscopy and FIB-SEM have shown how Mycobacterium tuberculosis, first confined within a membrane-bound phagosome, could escape to the cytoplasm of their host macrophage,. A multimodal vCLEM approach was used with ssTEM, SBF-SEM and FIB-SEM to validate zebrafish as a model system for studying Toxoplasma gondii infection, showing that macrophages have a role in parasite clearance in vivo. Likewise, FIB-SEM revealed the complex structure of T. gondii rosette formation and connectivity, and cell-cell interactions at the virological synapse in HIV infection.
Immune cell-cancer interactions
The whole cell volume of a mouse cytotoxic T lymphocyte forming an immunological synapse with an ovarian cancer cell was revealed using FIB-SEM; the topology of this system was previously difficult to study in detail. In more complex multicellular organisms, intercellular communication is crucial, and one such mediator of crosstalk and material transfer is thought to be tunnelling nanotubes. Using vEM, tunnelling nanotubes have been shown to play a role in the stroma-mediated protection of leukemic cells through cell-cell vesicle trafficking, and microtubule bridges connecting cells in the early mammalian embryo have been shown to facilitate membrane transport between cells.
Nerve cell interactions
vEM has been widely used to examine cell-cell interactions in neuroscience. In the mouse brain, ssTEM showed that ultrastructural features of the blood brain barrier, including increased pericyte-brain endothelial cell contact, are altered during aging, and single axons form clustered compound multi-synaptic contacts of distinct morphologies with individual neurons, thus maximizing their influence on the postsynaptic neuron. FIB-SEM has been used to demonstrate that some primary cilia form serotonergic axo-ciliary synaptic contacts in the hippocampus. SBF-SEM was used to reconstruct two individual cells from a large dataset of a leech ganglion, discovering new connections. Inferences were also made about previously unstudied pathways, validated by post hoc comparative electrophysiological measurements in matched living tissues. Tran et al. demonstrated an elegant co-culture system, designed to examine neuron-neuron interactions in detail with FIB-SEM and ssTEM. Using array tomography, synaptic inputs and outputs of an inhibitory interneuron were mapped.
vEM at the organism and tissue scale
vEM reveals principles of tissue organization that are impossible to capture with 2D approaches or with lower resolution methods. For example, array tomography of mouse ovarian follicles uncovered previously unknown complex interactions between different cell types via cytoplasmic extensions and gap junctions. vEM has now been adopted for tissue scale investigations across species (Fig.7), including in plants,, and a variety of insects, and other arthropods. vEM of the nervous system, in particular, has rapidly advanced in recent years, because mapping neuronal circuits at synaptic resolution is considered essential to understanding how the brain works and how specific behaviours are generated (Fig.8). Thus, within the past 10 years an impressive number of large vEM datasets of brain tissue have been produced, including the full or partial connectomes of the mammalian retina,, ascidian tadpole larva Ciona intestinalis, the larva and adult Drosophila brain,,, zebrafish brain,, a cubic millimetre of mouse brain, a cubic millimetre of human brain and the pathoconnectome of a degenerating human retina to study neurological diseases. This list continues to grow at pace, and it is now possible to image the connectomes of several individuals from the same species (C. elegans) to address questions of development and plasticity. Peripheral nervous system investigations have also benefited from vEM, for example by understanding the structure and connectivity of cell types within the mouse circumvallate taste bud. For smaller organisms, vEM of the entire body (Platynereis larvae,) enables investigations of the structure and function of the nervous system in the context of the whole body and its interactions with the environment.
In addition to addressing the research question that initially motivated their collection, such large vEM datasets have also proven to be a valuable resource for addressing unrelated questions at various scales. For example, a vEM dataset from mouse cortex was generated to investigate the rules of neocortical synaptic connectivity, and has also been used to define the 3D organization of the endoplasmic reticulum, the structure of mitochondria and the distribution of myelin in axons of neocortical pyramidal neurons.
vEM in the clinical setting
Electron microscopy has long been used as a tool in the clinic, most commonly in diagnosis of ciliopathies and in renal pathology. Diagnostic electron microscopy generally uses TEM to deliver the resolution needed to measure defects in, for example, the central complex and microtubular arrangements in cilia in primary ciliary dyskinesia, and glomerular structures including the basement membrane in the kidney. A recent move has seen several teams investigate the potential of vEM techniques to reveal additional diagnostic features in volumes greater than that of a single ultra-thin section. Doubling the imaged volume using dual-axis electron tomography and sub-tomogram averaging demonstrated that a reduction in proximal outer dynein arm volume could be detected in archived specimens from patients with primary ciliary dyskinesia with a mutation in the DNAH11 gene, that could not be seen using standard ultrathin sections. Other work has demonstrated that SBF-SEM can reveal disruption of the glomerular basement membrane and associated changes in podocyte cell contacts in human biopsy samples from lupus nephritis and patients with IgA nephropathy. In these cases, image volumes and segmentation were essential to trace and capture penetrations of cells through the basement membrane and rare cell-cell contact events. vEM techniques are now finding broader application in clinical research, to study synapse organization in post-mortem brain from patients with Alzheimer’s disease and organelle changes in Parkinson’s disease, the tumour microenvironment in cancer biopsy samples –, cell-cell contacts in the alveolar epithelium of the lung using archival material and the osteocyte and lacuno-canalicular network in osteoarthritic and osteoporotic human bone.
Reproducibility and data deposition
Biological electron microscopy is still largely a manual discipline. Samples are typically prepared using customized protocols tailored to the research question and qualitative observations are often made on a small number of hand-selected images. This approach has led to seminal discoveries in biology yet limits throughput and complicates reproducibility. However, recent community efforts aim to produce data and tools that will support reproducibility in vEM.
Factors influencing reproducibility
The vast heterogeneity of biological samples and applications preclude a universal vEM sample preparation protocol, as evidenced by the daunting number of published protocols. Reproduction is confounded by historical differences in protocols between laboratories; the number of steps in sample preparation workflows, which deters users from optimizing adequately working protocols; variation in reagent batches; a lack of standard parameters and quality control metrics; and the absence of a repository of reference protocols with corresponding images showing examples of data of varying quality. To address these issues, reference protocols and consensus guidelines on optimization of workflows must be agreed within the expert vEM community. The production of benchmark specimens from different laboratories using these reference protocols will allow assessment of local variables. Public availability of these data will allow crowdsourcing or artificial intelligence approaches to derive quality control scores. Increased throughput of sample preparation using microwave processing and robotic devices will also support reproducibility.
The community currently lacks a standard set of quality control checks for the microscopes used to acquire vEM data, but inspiration can be taken from the introduction of guidelines and standards for quality control by the QUAREP-LiMi consortium in light microscopy. Empirical and heuristic choices made during image acquisition, plus (hidden) differences in the state of the instrument mean that imaging runs are rarely reproducible between laboratories. Benchmark specimens prepared from reference protocols would allow acquisition of benchmark datasets, which could be publicly deposited and used to better understand differences between microscopes and imaging parameters. Fixing parameters could result in reliably repeatable acquisition runs. Environmental stability during long imaging runs is critical for quality and reproducibility, and accurate monitoring of section thickness would improve the fidelity of downstream image volume reconstruction. Automation of imaging and internal quality control steps, such as on-the-fly focus and stigmation corrections, and feedback loops to maintain spatial fidelity are critical aspects of vEM. Lack of full reporting of image acquisition parameters has historically limited the reproducibility of vEM experiments, and therefore community consensus on parameters to be reported for each vEM imaging modality would provide valuable guidance and extend the recently published REMBI minimal metadata recommendations to support reproducible vEM data acquisition.
A lack of metrics for vEM data means that quality control and optimization are based on manual visual inspection. To improve this, the vEM community can take inspiration from the work of the cryo-EM community on gold standards. As with sample preparation, there is no silver bullet software package that can seamlessly process and analyse all vEM datasets. Most researchers use a mix and match/trial and error approach to visualize and mine their image data, slowing optimization and complicating reproducibility. Community guidelines on reporting methods for processing and analysis of vEM data are critical for reproducibility of published work,. Image-to-image and multimodal registrations should be published and/or publicly deposited with accompanying landmark and transformation files for reproducing such registrations. Segmentation is still largely a manual process, despite progress in the development of machine learning algorithms, and known inter-expert variations on segmentation tasks raise questions around the fidelity of ground truth,. Inter-expert variation is often due to inadequacies in the datasets; for example, sections may be too thick to resolve very thin axons, or to identify synapses that are sectioned parallel to the postsynaptic density, and missing sections and specimen contamination contributes to errors. Further development of machine learning approaches will succeed only with parallel improvement of data quality. Publication of usable models with accompanying weights within containerized workflows will allow reproduction of inferences.
Data handling and deposition
Community surveys suggest that many labs are collecting vEM datasets in the 10-100 GB range, with images saved to disk in proprietary or tiff file formats, transferred to a server and downloaded by users for downstream analysis using desktop software programs as cropped or binned image stacks. However, as vEM datasets reach the terabyte regime, this approach breaks down and data handling must be carefully planned with the support of scientific computing specialists. Institutions hosting vEM technology must consider related computational expenses and hire dedicated personnel to optimize and streamline data handling. Traditional file formats, such as mrc and tiff, fail at the terabyte scale and next generation file formats are being developed that dynamically access chunks of data via cloud storage and compute, bypassing the need to download entire datasets. Public deposition of image data and associated metadata in image archives such as EMPIAR and the BioImage Archive are critical in driving full analysis and reanalysis of rich vEM datasets by a distributed user base, as well as aiding development of automated image analysis tools and supporting meta-studies into reproducibility.
Limitations and optimizations
As may be expected in a nascent field, there are currently a range of limitations affecting vEM, giving rise to an exciting and dynamic technology research, development and innovation environment. Stable, supported and accessible solutions will help overcome these obstacles and drive the adoption of vEM by the wider biological community.
Sample preparation
Ideally, cells and tissues would be cryofixed (to ensure that dynamic events are captured) and imaged at cold temperature (to avoid shrinkage and warping artefacts due to dehydration). However, the limitation in the depth of vitrification of biological samples is ~200 μm, far below the size of most samples destined for vEM. Serial imaging of small volumes (<10 μm) of vitrified samples is possible using cryo FIB-SEM, or cryo soft X-ray tomography. Reassuringly, images of 3D ultrastructure from cryo soft X-ray tomography show that most vitrified cell structures have a similar appearance to those seen in room-temperature vEM, suggesting that shrinkage artefacts will not invalidate interpretation for many biological questions. A further complication of working with human tissue samples for vEM is the incompatibility of clinical processing (wax embedding and snap freezing) with good ultrastructure, and the deterioration of ultrastructure of post-mortem samples prior to fixation, a complication that was critically evident in the early stages of the COVID-19 pandemic. A lack of protocols for introducing immunolabels deep into tissue without membrane-destabilizing permeabilization techniques (methanol, Triton and so on) also hinders molecular localization in tissues, while high-contrast genetic probes that are still visible with multiple layers of heavy metal staining are only now being developed.
Imaging
vEM, similar to most imaging modalities, falls foul of the trade-off between speed of image acquisition, resolution of the images and the volume that can be imaged. Brute force speed-up of image acquisition results in lower signal and image quality, whereas targeted imaging may obscure important tissue context, and automated imaging of ROIs may lower the chance of serendipitous discovery by biasing acquisition. Long imaging runs and parallelization by installation of multiple instruments are possible but expensive and, currently, only implemented in a handful of dedicated facilities worldwide,.
Data analysis
vEM data analysis is still a massive bottleneck, being largely manual, and therefore time and resource intensive. The volume that can be analysed and the number of features that can be extracted are limited. Furthermore, most vEM analysis workflows require some level of bespoke customization, depending on the research question, sample type, sample preparation, imaging modality and quality and format of the acquired data. A mishmash of constantly evolving open-source, in-house and commercial software packages add complexity for non-expert end users. The application of machine learning will alleviate some of these analysis burdens, but universal models are not yet a reality. The infancy of the field demands significant computational literacy in researchers to create or tweak algorithms and track and correct errors. vEM data analysis is a research area in flux, but a strong push toward open-source solutions will ideally prevent siloed computational solutions.
Outlook
The development of new tools and technologies has underpinned great advances in our understanding of how cells, tissues and organisms function in health and disease. Electron microscopy has been central to these advances, being the only technique that can reveal the structure of cells and tissues with the contrast and resolution to distinguish membranes and membrane bilayers. Whereas the challenge in genomics, proteomics and metabolomics has been to move from systems-level analysis to single cells, the challenge for electron microscopy has been to move from the single-cell level to a systems-level view of samples. vEM offers this opportunity.
The field is evolving rapidly, as more scientists realize the potential of vEM to contribute new insights into their research questions. This has attracted tool developers, in the form of microscopists, physicists, chemists, engineers and computational scientists, focused on improving the speed and throughput of vEM. Having originated in connectomics and neuroscience, the next grand challenge appears to be the mapping of the connectome of a single mouse brain. Rapid high-resolution image acquisition will also help to overcome the n-of-1 problem, allowing the analysis of multiple samples from a population to assess inter-organism variability. As we have already seen, technological advances focused on one challenge area (like the brain) quickly radiate out to drive discovery in other biological and clinical research areas.
A particular challenge lies in true multiscale imaging of tissues and organisms, to provide multidimensional views of samples with low-resolution and high-resolution information accessible from a single volume. The creation of multiscale digital twins will require parallel developments in light, X-ray and electron imaging, alongside improvements in sample preparation, multimodal probes and multiscale analysis and visualization. There are two crossover points in scales that currently block the creation of seamless image volumes from patient to protein. One is at the cryo-resin interface, at a sample thickness of between 1 μm and 200 μm, where 1 μm is the (somewhat generous) limit of continuous volume that can be imaged with cryo-ET to identify macromolecules in situ in cells, and 200 μm is the hard limit of vitrification, above which resin protocols effectively destroy or mask atomic structure. The second is at a sample thickness greater than 1 mm, above which diffusion limits the penetration of chemicals into the sample. Overcoming these blocks will require broad multidisciplinary collaboration between structural biologists, volume electron microscopists, light microscopists and pre-clinical and medical imaging scientists, with biologists, clinician scientists and the tool developers mentioned above.
The scale of this challenge requires investment into specialist facilities that gather a range of expertise and infrastructure. Deployment will then require roll out of new tools to specialist core facilities that will offer open access to a broad swathe of researchers, who will, in turn, depend on local facilities to perform fast effective sample preparation close to the end-user. Indeed, these local facilities are key in supporting the boom in vEM use, and are a source of valuable advice about experimental design and vEM modality selection for a specific biological question. However, the number of vEM experts is likely to become limiting as vEM technology is more widely adopted, a limitation already affecting the cryo-EM field, and it will be critical to develop and implement formal training programs, rather than the on-the-job training model currently used. Creation of a network of local, national and international open access vEM facilities will require a coordinated effort from the vEM community and funders, and will take time. In the meantime, vEM specialists and end-user researchers are encouraged to join the burgeoning community via the vEM community website or to contact their local electron microscopy facility for support and information.
If the effort to build a vEM infrastructure and community is successful, then we should see a move towards a new discipline of morphometrics, in which the number of samples imaged and analysed will provide statistically significant insights into the nanoscale spatial organization of organelles, cells, organs and systems. Crossing discipline boundaries, integration of spatial proteomics, transcriptomics and metabolomics data will add volume function to volume structure to drive a new era of functional morphometrics.
Supplementary Material
Supplementary information is available for this paper at https://doi.org/10.1038/s43586-022-00131-9
References 301
- 1.
Abbott LF, et al. The Mind of a Mouse. Cell. 2020;182:1372-1376.
Not in our library10.1016/j.cell.2020.08.010
- 2.
Guerin CJ, Lippens S. Correlative light and volume electron microscopy (vCLEM): How community participation can advance developing technologies. J Microsc. 2021;284:97-102.
Not in our library10.1111/jmi.13056
- 3.
Peddie CJ, Schieber NL, Collinson Lucy, Verkade Paul. Correlative Imaging: Focusing on the Future. 2020;37-66.
Not in our library
- 4.
Hayat MA. Principles and Techniques of electron microscopy: biological applications. 2000;45-61.
Not in our library
- 5.
Titze B, Genoud C. Volume scanning electron microscopy for imaging biological ultrastructure. Biology of the Cell. 2016;108:307-323.
Not in our library10.1111/boc.201600024
- 6.
Ströh S, Hammerschmith EW, Tank DW, Seung HS, Wanner AA. In situ X-ray assisted electron microscopy staining for large biological samples. bioRxiv. 2021;2021.2006.2019.448808.
Not in our library10.1101/2021.06.19.448808
- 7.
Russell MRG, et al. 3D correlative light and electron microscopy of cultured cells using serial blockface scanning electron microscopy. Journal of Cell Science. 2016;130:278-291.
Not in our library10.1242/jcs.188433
- 8.
Cortese M, et al. Integrative Imaging Reveals SARS-CoV-2-Induced Reshaping of Subcellular Morphologies. Cell host & microbe. 2020;28:853-866.
Not in our library10.1016/j.chom.2020.11.003
- 9.
Müller-Reichert T, Hohenberg H, O’Toole ET, McDonald K. Cryoimmobilization and three-dimensional visualization of C. elegans ultrastructure. Journal of Microscopy. 2003;212:71-80.
Not in our library10.1046/j.1365-2818.2003.01250.x
- 10.
Mulcahy B, et al. A Pipeline for Volume Electron Microscopy of the Caenorhabditis elegans Nervous System. Frontiers in neural circuits. 2018;12:94.
Not in our library10.3389/fncir.2018.00094
- 11.
Porrati F, Grewe D, Seybert A, Frangakis AS, Eltsov M. FIB-SEM imaging properties of Drosophila melanogaster tissues embedded in Lowicryl HM20. J Microsc. 2019;273:91-104.
Not in our library10.1111/jmi.12764
- 12.
Yoshida N, et al. The zebrafish as a novel model for the in vivo study of Toxoplasma gondii replication and interaction with macrophages. Dis Model Mech. 2020;13.
Not in our library10.1242/dmm.043091
- 13.
Hildebrand DGC, et al. Whole-brain serial-section electron microscopy in larval zebrafish. Nature. 2017;545:345-349.
Not in our library10.1038/nature22356
- 14.
- 15.
Mikula S, Denk W. High-resolution whole-brain staining for electron microscopic circuit reconstruction. Nature methods. 2015;12:541-546.
Not in our library10.1038/nmeth.3361
- 16.
Polishchuk RS, Polishchuk EV, Luini A. Visualizing live dynamics and ultrastructure of intracellular organelles with preembedding correlative light-electron microscopy. Methods Cell Biol. 2012;111:21-35.
Not in our library10.1016/b978-0-12-416026-2.00002-9
- 17.
McDonald K. Cryopreparation Methods for Electron Microscopy of Selected Model Systems. Methods Cell Biol. 2007;79:23-56.
Not in our library10.1016/s0091-679x(06)79002-1
- 18.
McDonald KL, Morphew M, Verkade P, Muller-Reichert T. Recent advances in high-pressure freezing: equipment- and specimen-loading methods. Methods Mol Biol. 2007;369:143-173.
Not in our library10.1007/978-1-59745-294-6_8
- 19.
McDonald KL. A review of high-pressure freezing preparation techniques for correlative light and electron microscopy of the same cells and tissues. J Microsc. 2009;235:273-281.
Not in our library10.1111/j.1365-2818.2009.03218.x
- 20.
Odriozola A, et al. High contrast staining for serial block face scanning electron microscopy without uranyl acetate. bioRxiv. 2017;207472.
Not in our library10.1101/207472
- 21.
Starborg T, et al. Using transmission electron microscopy and 3View to determine collagen fibril size and three-dimensional organization. Nature Protocols. 2013;8:1433-1448.
Not in our library10.1038/nprot.2013.086
- 22.
Mikula S, Binding J, Denk W. Staining and embedding the whole mouse brain for electron microscopy. Nature methods. 2012;9:1198-1201.
Not in our library10.1038/nmeth.2213
- 23.
Ronchi P, et al. High-precision targeting workflow for volume electron microscopy. The Journal of cell biology. 2021;220.
Not in our library10.1083/jcb.202104069
- 24.
Deerinck TJ, Bushong E, Thor A, Ellisman MH. NCMIR methods for 3D EM: A new protocol for preparation of biological specimens for serial block-face SEM. Microscopy. 2010;6-8.
Not in our library
- 25.
Tapia JC, et al. High-contrast en bloc staining of neuronal tissue for field emission scanning electron microscopy. Nature Protocols. 2012;7:193-206.
Not in our library10.1038/nprot.2011.439
- 26.
Lu Z, et al. En bloc preparation of Drosophila brains enables high-throughput FIB-SEM connectomics. bioRxiv. 2019;855130.
Not in our library10.1101/855130
- 27.
- 28.
Seligman AM, Wasserkrug HL, Hanker JS. A new staining method (OTO) for enhancing contrast of lipid-containing membranes and droplets in osmium tetroxide-fixed tissue with osmiophilic thiocarbohydrazide (TCH). The Journal of cell biology. 1966;30:424-432.
Not in our library10.1083/jcb.30.2.424
- 29.
Malick LE, Wilson RB. Modified thiocarbohydrazide procedure for scanning electron microscopy: routine use for normal, pathological, or experimental tissues. Stain Technol. 1975;50:265-269.
Not in our library10.3109/10520297509117069
- 30.
Willingham MC, Rutherford AV. The use of osmium-thiocarbohydrazide-osmium (OTO) and ferrocyanide-reduced osmium methods to enhance membrane contrast and preservation in cultured cells. J Histochem Cytochem. 1984;32:455-460.
Not in our library10.1177/32.4.6323574
- 31.
- 32.
Nakakoshi M, Nishioka H, Katayama E. New versatile staining reagents for biological transmission electron microscopy that substitute for uranyl acetate. J Electron Microsc (Tokyo). 2011;60:401-407.
Not in our library10.1093/jmicro/dfr084
- 33.
Kuipers J, Giepmans BNG. Neodymium as an alternative contrast for uranium in electron microscopy. Histochemistry and Cell Biology. 2020;153:271-277.
Not in our library10.1007/s00418-020-01846-0
- 34.
McDonald KL. Out with the old and in with the new: rapid specimen preparation procedures for electron microscopy of sectioned biological material. Protoplasma. 2013;251:429-448.
Not in our library10.1007/s00709-013-0575-y
- 35.
Hoffman DP, et al. Correlative three-dimensional super-resolution and block-face electron microscopy of whole vitreously frozen cells. Science (New York, NY). 2020;367:eaaz5357.
Not in our library10.1126/science.aaz5357
- 36.
Luft JH. Improvements in epoxy resin embedding methods. J Biophys Biochem Cytol. 1961;9:409-414.
Not in our library10.1083/jcb.9.2.409
- 37.
Glauert AM, Rogers GE, Glauert RH. A New Embedding Medium for Electron Microscopy. Nature. 1956;178:803.
Not in our library10.1038/178803a0
- 38.
Kellenberger E. Low denaturation embedding for electron microscopy of thin sections. 1980.
Not in our library
- 39.
Armbruster B, et al. Specimen preparation for electron microscopy using low temperature embedding resins. Journal of microscopy. 1982;126:77-85.
Not in our library10.1111/j.1365-2818.1982.tb00358.x
- 40.
Stäubli W. A new embedding technique for electron microscopy, combining a water-soluble epoxy resin (Durcupan) with water insoluble araldite. The Journal of cell biology. 1963;16:197-201.
Not in our library10.1083/jcb.16.1.197
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.