Skip to content
naulon
Not checkedNot checked for notices yet.

Conjugate heat transfer study of various cooling structures and sensitivity analysis of overall cooling effectiveness

Runzhou Liu, Haiwang Li, Ruquan You and 2 more

Scientific Reports · 2022

doi:10.1038/s41598-022-23948-6 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

The conjugate heat transfer of a turbine blade is influenced by several factors. To analyze the influence of each factor, the published one-dimensional conjugate heat transfer model was improved through theoretical analysis in this study. An overall cooling effectiveness equation containing three dimensionless parameters (adiabatic film cooling effectiveness η , Biot number on the mainstream side Bi g , and ratio between the heat transfer coefficients of the external and internal walls h g / h i ) was obtained. The sensitivity of the overall cooling effectiveness ϕ to these three parameters was obtained through a multi-parameter sensitivity analysis. The results showed that increasing η could improve ϕ the most effectively. The interactions between the dimensionless parameters were analyzed by developing sensitivity charts. The results showed that increasing η from 0.4 to 0.5 could reduce the sensitivity of ϕ to the other two parameters by approximately 15%, whereas increasing Bi g had little effect on the sensitivity of ϕ to each dimensionless parameter. Increasing h g / h i could improve the sensitivity to η . The above conclusions could also be applied to the plate film hole and plate impingement effusion structures. The effects of different internal cooling structures and film hole structures on the three dimensionless parameters were studied by performing numerical simulations, which verified the accuracy of the one-dimensional conjugate heat transfer model in this study. The results showed that the internal cooling structures had little effect on the distribution of η and Bi g . The heat transfer coefficient on the coolant side could be effectively improved by installing film holes. The film hole structures mainly affected ϕ by influencing the distribution of η .

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.