No retraction, correction or concern found when last checked on Oct 27, 2026.
Analysis of reactive oxygen and nitrogen species generated in three liquid media by low temperature helium plasma jet
Julie Chauvin, Florian Judée, Mohammed Yousfi and 2 more
Scientific Reports · 2017 · CC BY
doi:10.1038/s41598-017-04650-4
Abstract
In order to identify aqueous species formed in Plasma activated media (PAM), quantitative investigations of reactive oxygen and nitrogen species (ROS, RNS) were performed and compared to Milli-Q water and culture media without and with Fetal Calf Serum. Electron paramagnetic resonance, fluorometric and colorimetric analysis were used to identify and quantify free radicals generated by helium plasma jet in these liquids. Results clearly show the formation of ROS such as hydroxyl radical, superoxide anion radical and singlet oxygen in order of the micromolar range of concentrations. Nitric oxide, hydrogen peroxide and nitrite-nitrate anions (in range of several hundred micromolars) are the major species observed in PAM. The composition of the medium has a major impact on the pH of the solution during plasma treatment, on the stability of the different RONS that are produced and on their reactivity with biomolecules. To emphasize the interactions of plasma with a complex medium, amino acid degradation by means of mass spectrometry was also investigated using methionine, tyrosine, tryptophan and arginine. All of these components such as long lifetime RONS and oxidized biological compounds may contribute to the cytotoxic effect of PAM. This study provides mechanistic insights into the mechanisms involved in cell death after treatment with PAM.
Full text
From PubMed Central, U.S. National Library of Medicine, as current on Oct 27, 2026. Paragraph numbers are ours, so an answer can point at one.
Introduction
Low temperature plasmas generated at atmospheric pressure have been studied in the past few years for their applications in the field of medicine and biomedicine. Short and long lived reactive oxygen (ROS) and nitrogen species (RNS) can be generated by non-thermal plasmas in either gaseous or aqueous forms when primary plasma species (ions, electrons, radicals, and dissociated molecules) interact with a liquid phase–. It is noteworthy that plasmas can induce either cell proliferation for low doses or cell death by apoptosis for high doses of exposure,. Low temperature plasmas have therefore been studied intensively for wound healing, sterilization, blood coagulation, dental treatment, and also for the inactivation of various cancer cells from breast, head and neck, ovarian, lung, prostate or colorectal tissues–. It has been shown that plasma species can inactivate cancer cells either directly (interactions of gaseous species with cells) or indirectly when using a previously-prepared plasma-activated liquid media (PAM). In addition, such plasma treatments can selectively inactivate cancer cells without really affecting normal cells, –. Interestingly, PAM have numerous advantages: i) they allow selective treatment of internal organ cancer tissues which are difficult to reach by the gaseous species and requiring endoscopes or catheters; ii) they present minimal toxicity for normal tissues; and iii) they remain stable several days after their preparation if they are stored at the right temperature,,. In PAMs, reactive oxygen and nitrogen species (RONS) have been shown to induce cancer cell apoptosis,, although the cell death pathways at a molecular level have not yet been clearly elucidated, some studies have suggested mitochondrial dysfunction,. Identification and quantification of the aqueous RONS generated in PAMs could therefore shed light on the mechanisms of action of PAM with regard to tumor eradication and wound healing. We have already described the genotoxic and cytotoxic effects of PAMs on colon adenocarcinoma multicellular tumor spheroids and its selective action on cancer cells elsewhere,.
Furthermore, most of plasma devices described in the literature which are used to generate PAMs are based on dielectric barrier discharge setups (DBD) using RF, AC or pulsed power supplies with different carrier gases such as helium,,, helium with oxygen, or argon,. The nature and quantity of the plasma species generated depend on the type of plasma device used and the carrier gas composition. Hence, there is a real demand for the identification and quantification of the aqueous RONS (superoxide anion radical, hydroxyl radical, singlet oxygen, nitric oxide, hydrogen peroxide, nitrite/nitrate, etc.) generated when the gaseous plasma species impact the liquid media. Several techniques are currently used to identify and quantify the gaseous plasma products, including optical emission spectroscopy (OES) or laser induced fluorescence–. However, aqueous plasma by-products with a short lifetime are difficult to quantify using OES,, and other methods including chemical dosimetry or fluorescent probes, electron paramagnetic resonance (EPR) spectroscopy– appear more appropriate. The later technique requires specific spin traps to allow detection of some aqueous plasma by-products.
The overall goal of this study is the analysis of several plasma-induced free radicals in three liquid media, i.e. Milli-Q water and a cell culture medium, DMEM, with and without fetal calf serum (FCS), which are exposed to a low temperature plasma jet generated by a DBD setup using helium carrier gas at atmospheric pressure. These different liquid media are activated by the plasma jet using different exposure times. The RONS investigated are hydrogen peroxide (H2O2), hydroxyl radical (•OH), singlet oxygen (1O2), superoxide radical (O2 •−), nitric oxide (NO•) and nitrite/nitrate anions (NO2/NO3). H2O2 was measured using a fluorometric kit and NO2/NO3 with a colorimetric kit, while the three other free radicals were quantified using EPR spectroscopy and spin traps due to their short life spans.
Hydroxyl Radical (•OH) produced in liquid media by He plasma jet
In order to characterize the formation of reactive oxygen species in different media such as Milli-Q water, a cell culture medium, DMEM, without or with fetal calf serum (FCS) upon exposure to cold plasma, spin trapping experiments were carried out using 5,5-dimethyl-1-pyrroline N-oxide (DMPO) as spin trap. Figure 1 shows the electron paramagnetic resonance (EPR) spectrum of DMEM containing DMPO exposed to the plasma jet for 150 s. Whatever the medium, the EPR spectrum recorded corresponds to the superposition of two signals. The first and the most intense signal yielded the following hyperfine coupling constants aN = aH = 15 G, g = 2.0056 and peak intensity ratio of 1:2:2:1 (Fig. 1, #) which is attributed to DMPO-OH adduct,,, –. The second signal (Fig. 1, *) is a triplet having aN = aH = 15 G, g = 2.0056 and peak intensity ratio of 1:1:1. This signal is also observed in untreated media (Milli-Q water or DMEM +/− FCS) (data not shown). Under similar experimental conditions, this second signal was also been observed by Tresp et al. and was assigned to DMPO-CH3 adduct. DMPO-CH3 spin adduct can only originate from the spin trap itself since no carbon-based molecules are present in Milli-Q water. This assumption seems to be confirmed by the absence of correlation between the signal intensity and the exposure time of the media to the plasma jet.
•OH radical can be formed by the reaction of an oxygen atom with an H2O molecule at the liquid surface, or from the solvation of gaseous •OH produced in the gas phase of plasma giving rise to the production of aqueous •OH radicals. In a previous work, the presence of oxygen atom and OH radical species was validated by observing their specific radiation using emission spectroscopy This indicates that both pathways may be involved in our experimental conditions. This assumption is supported by the data published by Gorbanev et al. showing that with dry feed He plasma, OH radical may be produced both in the gas phase and in the sample.
The concentration of OH radical was assessed by exposing the different media with DMPO spin trap to cold plasma. As shown in Fig. 2, the concentration of DMPO-OH adduct increases linearly with the plasma exposure time (R²water = 0.99, R²DMEM = 0.98, R²DMEM + FCS = 0.92) indicating an increase of OH radical production. Kanazawa et al. have already shown similar linear relationship between the amount of OH radical in water and the time of exposure to He plasma jet. For this purpose, they used chemical dosimetry based on the reaction of terephthalic acid with OH radical to generate a fluorescent molecule.
The concentration of DMPO-OH is evaluated around 4.12 µM, 3 µM and 0.4 µM after 150 s exposure to He plasma in water and DMEM +/− FCS, respectively. The amount of DMPO-OH detected in water is higher than in both biological media. Indeed, OH radicals generated in water are surrounded only by water molecules and other types of radicals. In cell culture media, OH radicals can oxidize organic components such as amino acids, vitamins and proteins. These oxidation reactions will reduce the quantities of OH radical trapped by DMPO. Chemical reactions between amino acids and OH radicals were predicted by reactive classical MD simulations and observed by high-resolution mass spectrometry.
We have estimated the half-life of DMPO-OH in the three media considered Milli-Q water and DMEM +/− FCS. To estimate the half-life of DMPO-OH, the signal decay of DMPO-OH was studied from 120 s to 2000 s after plasma exposure. The data were fitted with a polynomial profile of the 3rd order. The results summarized in Table 1 show that the half-life of DMPO-OH adduct depends on the composition of the medium. In Milli-Q water, the adduct half-life was evaluated at 820 s which is very close to the 870 s found in the literature. In DMEM +/− FCS the half-life was about 1043 s and 442 s, respectively. The stability of the adduct DMPO-OH is affected by the change in pH and/or the presence of nitric acid,. The results suggest that DMEM makes it possible to maintain the pH constant at around 7.4 after exposure to plasma leading to an increase in the stability of the DMPO-OH adduct. In the presence of FCS, its stability is around 2 or 2.3 times lower than in water and DMEM respectively. This might be explained by the fact that the adduct can bind to proteins such as albumin which have documented anti-oxidant properties and/or by the presence of higher quantities of nitric acid than in water and DMEM as we will show in the section nitrite/nitrate anions of manuscript. Nitrite may react with OH radical to form peroxynitrite.
Formation of Superoxide Anion Radical (O2•−) by the plasma jet in media
DMPO used as a spin trap in EPR experiments can react with many ROS under different rate coefficients and trapping times. The EPR signal obtained after plasma exposure (Fig. 1) of the different media containing DMPO is clearly defined as the signal of the DMPO-OH spin adduct. However the mechanism is more complex than it seems. DMPO shows a significant preference for the hydroxyl radical (kOH > 109 M−1s−1, ) but can also scavenge superoxide anion to form the spin adduct DMPO-OOH which has a much lower reaction rate (kO2− < 102 M−1s−1, ). The difficulty lies in the fact that adduct DMPO-OOH tends to decompose rapidly in DMPO-OH, making it difficult to detect.
To highlight the presence of superoxide anion in the media after plasma treatment, superoxide dismutase (SOD) was added before plasma exposure. Found in almost all aerobic organisms this enzyme is a metalloprotein that catalyzes the dismutation of superoxide anion radical into molecular oxygen and hydrogen peroxide. The addition of SOD (150 units of SOD per well) to the media leads to the dismutation of the superoxide anion and thus to inhibition of DMPO-OOH spin adduct formation when exposed to plasma. In water, the addition of SOD leads to a decrease of about 10.2 ± 3.34% in the concentration of DMPO-OH adduct (Fig. 3). This indicates that a small part of the DMPO-OH signal comes from the decomposition of DMPO-OOH into DMPO-OH. It is interesting to note that the amount superoxide anion produced increases linearly with the exposure time. This evolution was also observed by Arjunan and Chyne using Tempo-9AC (fluorescent probe) and DBD plasma generated in humid ambient air. Superoxide anion is detected in water but in a much lower concentration than OH radical.
Quantification of the Hydrogen Peroxide (H2O2) concentration produced in PAM by He plasma jet
H2O2 is one of the main ROS produced by cold plasmas,,,,,. As proposed by Gorbanev et al., H2O2 is generated inside the plasma and is delivered into the medium. In our previous work,, we showed that hydrogen peroxide produced in PAM remains stable when PAM is stored at 4 °C for at least 7 days. H2O2 may be considered to be a central genotoxic agent produced during the exposure of media to a He plasma jet. This activity may be attributed to its ability to diffuse through cell membrane and to generate OH radical through a Fenton reaction catalyzed by iron containing proteins. Hydroxyl radical is known for its high reactivity with cellular components, its potent ability to induce DNA damage such as guanine oxidations, DNA cleavage and to cause cell death.
The formation of H2O2 by He plasma jet was characterized and quantified using a fluorometric Hydrogen Peroxidase Assay kit (procedure described in Material and Methods).
As shown in Fig. 4, the H2O2 concentration in Milli-Q water and cell culture media increases linearly with the exposure time to the plasma jet (R²water = 0.93, R²DMEM = 0.97, R²DMEM + FCS = 0.99). The linear increase in hydrogen peroxide concentration versus exposure time was also reported by Adachi et al. using an Argon plasma jet and a DMEM cell culture medium. In the three different media, the hydrogen peroxide concentration can reach 1.60 mM ± 0.12 mM for 150 s of plasma exposure time. This is also very close to the concentration determined in our previous studies,. The H2O2 quantities found are similar to those obtained by Tresp et al.using argon plasma to treat saline solution, buffered saline solution and cell culture medium. In contrast to OH radical and superoxide anion radical, the quantities of hydrogen peroxide produced do not depend on the type of the medium treated. This result suggests that H2O2 will not be consumed via a Fenton reaction in DMEM +/− FCS.
Singlet Molecular Oxygen (1O2) induced in the liquid media exposed to the plasma jet
It has been shown that singlet oxygen may be generated in water or cell culture media after the treatment of these liquid media by He plasma jet and Air DBD plasma,,. Wu et al. suggested that singlet oxygen was produced in plasma and diffused into the solvent.
In order to characterize the formation of singlet oxygen in the different media after plasma exposure, EPR experiments were performed using 2,2,6,6-tetramethylpiperidine (TEMP) as the spin trap. As shown in Fig. 5a, the EPR signal of Milli-Q water exposed for 150 s to plasma in the presence of TEMP is characterized by 3 peaks with an intensity ratio of 1:1:1 triplet with hyperfine coupling constants aN = aH = 16 G, g = 2.0059. This signal, detected in the three media, is attributed to the TEMPO spin adducts indicating the formation of singlet oxygen or ozone upon exposure to the He plasma jet. In water, the amount of TEMPO increases linearly with the exposure time (R²water = 0.98, R²DMEM = 0.95, R²DMEM+FCS = 0.88) (Fig. 5b). The addition of NaN3 (50 mM), a selective scavenger of singlet oxyimen– in water before plasma exposure induced a decrease of around 80% and 51% of the formation of TEMPO after 30 s and 150 s of exposure. This data clearly shows that the formation of TEMPO results from the oxidation of TEMP by singlet oxygen. Moreover, in our plasma jet configuration, with pure He, ozone cannot be detected along the plasma jet by using the UV absorption method at 253.7 nm. This indicates that ozone concentration is very low or negligible. This observation is also in good agreement with the investigations of Kawasaki et al.. Both data show that involvement of ozone to the oxidation of TEMPO is negligible in our experimental conditions. The concentration of TEMPO produced in water was evaluated to be about 13.85 µM after 150 s exposure to the plasma jet. The intensity of the TEMPO spin adduct signal in both DMEM and DMEM + FCS is negligible when compared to the case of Milli-Q water. This may be explained by the fact the singlet oxygen is a very high reactive oxygen species known to oxidize cysteine, methionine and tryptophan free amino acids and proteins. Singlet oxygen is consumed in both DMEM and DMEM with FCS. It is worth noting that singlet oxygen contributes to the formation of oxide radicals in PAM leading to a depletion of cellular nutrients. The formation of these oxidized by-products in DMEM +/− FCS may also contribute to the cytotoxic effects of PAM.
Hydrogen radical (•H) induced in liquid media by plasma treatment
Hydrogen radical was detected by EPR spectroscopy using α-phenyl-N-tert-butylnitrone (PBN) spin trap. The EPR signal obtained during plasma treatment of DMEM is shown in Fig. 6a. This signal is formed by 9 peaks with an intensity ratio of 1:2:1:1:2:1:1:2:1 and with hyperfine coupling constants aN = 16.2 G, aH = 10.3 G, g = 2.0776. It may be attributed to the PBN-H spin adduct. The PBN spin adduct of the •H atom was also observed with cold atmospheric dry-helium and argon plasma.
Moreover, a small magnitude signal associated with PBN-H is also observed in Milli-Q water and cell culture media not exposed to the low temperature plasma jet (Fig. 6b at time = 0). Signal intensity was totally independent of exposure time in Milli-Q water whereas it increased linearly in DMEM +/− FCS (R²DMEM = 0.96, R²DMEM + FCS = 0.97). These results suggest that the He plasma jet produces a small quantity of hydrogen radical. This is in total agreement with the spectroscopy studies showing that the He plasma jet generate very small amounts of gaseous H.
In the case of DMEM +/− FCS, the formation of hydrogen radical may be partly attributed to the reaction of ROS such as OH radicals with amino acids,. As shown in Fig. 6b, the formation of •H is higher in DMEM than in DMEM + FCS. This difference could be explained by the presence of albumin in DMEM + FCS, a protein known for its antioxidant properties and its ability to trap free radicals. This can lead to a decrease in the amount of ROS able to react with the amino acids in DMEM + FCS.
Nitric Oxide (•NO) formed in liquid media by plasma jet exposure
Nitric oxide was detected by indirect EPR spectroscopy using the Carboxy-PTIO spin trap that can react with nitric oxide to produce Carboxy-PTI and •NO2.,. Carboxy-PTIO and carboxy-PTI are stable molecular radicals that are detectable by EPR spectroscopy and have their own spectral signature. As shown in Fig. 7a the experimental signal of Carboxy-PTIO which is composed by 5 peaks with intensity ratio of 1:2:3:2:1 and hyperfine coupling constants aN = aH = 8.1 G, g = 2.0068 (this signal is obtained without any plasma treatment). Figure 7b shows experimental EPR signal obtained after exposure of 166 µM C-PTIO in Milli-Q water to the He plasma for 150 s. This signal consists of two superimposed radical spectra. The first one was identified as the remaining C-PTIO which does not react with nitric oxide (the simulated spectrum extracted from Fig. 7b is given in Fig. 7c). The second was the EPR signal of C-PTI (the simulated spectrum extracted from Fig. 7b is given in Fig. 7d) and presented 7 peaks with an intensity ratio of 1:1:2:1:2:1:1 and hyperfine coupling constants aN = 9.8 G, aH = 4.4 G, g = 2.0068. The presence of C-PTI in water after plasma exposure confirms the generation of nitric oxide.
As shown in Fig. 8, the formation of CPTI in Milli-Q water increases in a linear fashion with (R² = 0.98) exposure to the He plasma jet. The amount of •NO cannot be estimated from the amount of C-PTI formed because C-PTI may be reduced by both hydroxyl and hydrogen radicals to the parent C-PTIO. Nitric oxide in liquids arises after solvation of gaseous nitric oxide produced in the plasma plume observed using emission spectroscopy in our earlier study. Production of nitric oxide in liquids has already been observed in Milli-Q water after its exposure to helium or argon plasma and also in buffered saline solution treated with air plasma,. In aqueous solution, nitric oxide is a highly reactive species that may react with oxygen to produce nitrite (NO2 −) (Reaction 1). Formation of NO2 − in media is known to induce a decrease in the pH of the solution.
As shown in Fig. 9, we observed a drastic decrease in the pH of water from 6.5 to 4.5 upon plasma exposure. This result suggests the formation of reactive nitrogen compounds such as nitrous acid, nitric acid and peroxynitrous acid–. Nitrous acid, which is in acidic equilibrium with nitrite, may decompose in acidic medium into nitric oxide and nitrogen dioxide (Reactions 2 and 3). It is also known that nitrite is not stable under acidic conditions.
In water, nitric oxide may be regenerated via reaction 3. In contrast, in cell culture media the amount of NO radical detected is very low. Due to the presence of a buffer, for example phosphate buffer at pH 7.4 in these media, the change of pH will be very slight upon plasma exposure. In phosphate buffer, the pH varies by less than one pH unit At physiological pH conditions, nitrite will be more stable and subsequently reactions 2 and 3 will not occur or at least be limited in DMEM +/− FCS. This may explain the low concentration of NO in both cell culture media compared to water.
Another possible explanation for the low concentration of NO in biological liquids could be the high reactivity of this radical with bio-macromolecules. NO radicals and related species are able to modify proteins through chemical reactions without involving enzymes. Nitric Oxide groups can bind to a transition metal found in protein or thiol residues of amino acids such as cysteine. Tyrosine is one of the main target of RONS. Nitric oxide can also provide nitrogen sources for the formation of the nitro group (NO2). The presence of proteins and amino acids in culture medium can explain the low nitric oxide concentration detected in DMEM +/− FCS.
Nitrite (NO2−) and Nitrate (NO3−) anions generated in liquid media by plasma jet
The formation of nitrite and anions during exposure of the different media to a plasma jet was investigated and quantified. The concentration of nitrite in Milli-Q water and culture media (Fig. 10a) increases linearly with exposure time to plasma (R²water = 0.92, R²DMEM = 0.97, R²DMEM+FCS = 0.97). The nitrite concentration in DMEM with fetal calf serum is 2.87 ± 0.47 and 18.77 ± 2.26 times higher than in DMEM and in Milli-Q water respectively.
It is more difficult to quantify the nitrate anion concentration. Figure 10b shows the results in Milli-Q water and serum-free medium only. No anion values can be estimated for plasma jet exposure time of less than 90 s. Above 90 s of treatment, the anion concentration seems to increase linearly with the exposure time. As observed for nitrite, the nitrate anionconcentration is higher in DMEM than in Milli-Q water after 150 s of plasma treatment. Significant uncertainties in the nitrite concentration and the inability to quantify anion in DMEM + 10% FCS could be explained by the interactions between the species produced in this medium by plasma jet and Griess reagent or by the nitrite concentration which is lower than the limit of detection (i.e. 2.5 μM).
Moreover, the negligible values obtained during anion quantification may be due to the non-linearity of the calibration curves (see materials and methods) that increased significantly due to the dilution factor.
Nitrite and anions concentrations in PAM seem to be affected by the composition of the different media. Both nitrogen species are formed in plasma treated media through the dissolution of nitrogen oxides formed in plasma jet. Their formation and their stability in water and DMEM +/− FCS will depend on different parameters such as the pH of the solution, the presence of amino acids, metallo-proteins and the production of ROS by the He plasma jet. As mentioned above, we have observed in water a drastic decrease in pH, about 2 units, after 150 s exposure to He plasma. In these acidic conditions, nitrous acid (which is one of the major source of nitrite NO2 −) is not stable. It will decompose rapidly into nitrogen dioxide which may subsequently react with hydroxyl radicals produced by the He plasma jet. This chemical reaction leads to the formation of peroxynitrous acid which is not stable in acidic pH and converts into stable nitrate NO3 −. Lukes et al. have shown that, under acidic conditions, nitrite will react with hydrogen peroxide to generate peroxynitrite and subsequently nitrate anion. Girard et al. have clearly identified the formation of peroxynitrite anion in physiological pH under cold atmospheric plasma exposure. This cascade of chemical reactions may explain both the higher level of nitric oxide and the lower quantity of NO2 − in water than in DMEM +/− FCS. These reactions will be less efficient in buffered media with a pH of around 7. Hence, the nitrite concentration in DMEM +/− FCS will be higher than in water. Moreover nitrate/nitrite anions can be the targets of short lifetime ROS such as hydroxyl radical leading to the formation of peroxynitrite. In complex media such as DMEM +/− FCS, this reaction will compete with the oxidation of biomolecules by ROS. However, the production of peroxynitrite in biological media via this pathway will be minor. Also, the higher concentration of nitrite observed in DMEM + FCS than in DMEM may be explained by the presence of copper proteins such as cytochrome c in FCS that can contribute to the oxidation of nitric oxide into nitrite,.
The major source of anion in water and DMEM is the formation of nitrite anion and peroxynitrite. However, anions and nitrite are poorly reactive species with regards to bio-macromolecules. It is mostly ONOO−, NO2 •, N2O3 that will induce protein and DNA damage such as nitration and nitrosylation of amino acid residuals, nucleic acids and they will be partly responsible for the cytotoxic effect of plasma jet. In DMEM +/− FCS, these RNS will react with the biomolecules causing a decrease in the conversion of peroxynitrite in nitrate anion in these media. Taking into account all the factors influencing the reactivity of RNOS in solutions, the levels of nitrate anion observed should be water> DMEM > DMEM + FCS as was the case here.
It has been shown that nitrate and nitrite anions can be recycled in NO in cells. These inorganic anions produced in PAM are therefore potential sources of NO radicals. Depending on their concentrations, reactive nitrogen species (RNS) are known to have both deleterious and beneficial effects on cell dynamics. Interestingly, the RNS produced by cold atmospheric plasma jets and the quantity produced seem to induce the death of cancer cells in particular offering interesting selectivity between healthy and cancerous cells,.
Plasma treatment of aqueous solutions of amino acids
Oxidation of aqueous solutions of tyrosine, tryptophan, methionine and arginine after He plasma treatment were studied. The oxidized products were analyzed by HPLC coupled with mass spectrometry (HPLC-QTrap 4500-MS). In addition to the peaks corresponding to the reactants, the mass chromatograms of solutions exposed to plasma showed peaks corresponding to hydroxylation and nitration of tyrosine and tryptophane, sulfoxidation of methionine and hydroxylation of arginine (Figs S1–4 Supplementary data). All of these chemical modifications of amino acids by cold plasma were previously reported by Takai et al.. Figure 11 shows that, in descending order, the reactivity of the 4 amino acids is methionine > tryptophan > arginine > tyrosine. Methionine is totally degraded after 30 s exposure to cold plasma. Tyrosine is the only amino acid which is nitrated. All of these data are in accordance with the extensive literature on the reactivity of hydroxyl radical and RNS with amino acids and proteins. These data partially explain the difference in reactivity observed between biological media and water during cold plasma treatment and their different biological activity with regards to cancer cells.
Conclusion
We have characterized and quantified the formation of radical species such as hydroxyl radical, superoxide anion, singlet oxygen, nitric oxide and long lifetime RONS such as H2O2 and nitrite/nitrate anions in three culture media (Milli-Q water, DMEM and DMEM with FCS) exposed to a DBD plasma jet using helium at atmospheric pressure as a carrier gas. We have shown that the composition of the medium has a major impact on the pH of the solution during plasma treatment, on the stability of the different RONS that are produced and on their reactivity with biomolecules. Reactions of RONS with DMEM +/− FCS generate oxidized products which may be toxic for cells. Our data indicate that beside the production of long lifetime RONS, oxidized biological compounds form and accumulate in PAM leading to a decrease in essential nutrients for cell growth. All of these components such as long lifetime RONS and oxidized biological compounds may contribute to the cytotoxic effect of PAM previously observed on HCT116 spheroids,. Moreover, this suggests that the cytotoxicity of OH radical produced by He cold plasma jet can be mainly due to the production of cytotoxic chemicals in DMEM +/− FCS rather than a direct effect on cellular constituents. Moreover, long lifetime species (H2O2 and nitrites/nitrates) can penetrate into cells and can be potential precursors of intracellular reactive oxygen species. Indeed, these species can lead in turn to the formation of •OH radical via a Fenton reaction involving H2O2 and NO• synthesis via recycling of nitrites/nitrates anions by the cells. •OH radical and NO• are highly cytotoxic and genotoxic for cells. Therefore, under the present plasma exposure conditions, the obtained PAM can necessarily generate many potential cytotoxic and genotoxic by-products which have interesting applications, particularly for cancerous cell inactivation.
Plasma jet device
Figure 12 shows a diagram of the plasma jet device based on a dielectric barrier discharge configuration already detailed elsewhere,. In short, two aluminum tape electrodes are wrapped around a quartz tube and connected to a High-voltage mono-polar square pulses generator. A power supply with the following characteristics is applied: 10 kV voltage, 9.69 kHz frequency and 1 µs pulse duration. Helium gas flows through the quartz tube at a flow rate of 3 L min−1.
Preparation of Plasma Activated Medium (PAM)
Plasma activated medium (PAM), was produced by exposing 100 µL of water or cell culture medium DMEM with or without fetal to the He plasma jet. These different media were exposed for up to 150 s in 96 well plate, leading to a 20 µl decrease in volume after plasma exposure (data not shown). Plasma exposures were performed under the same experimental conditions (applied voltage, frequency, pulse duration and gas flow) and at the same distance of 2 cm between plasma jet tube output and the upper-surface of the liquid medium.
EPR spin-trapping spectroscopy
Electron paramagnetic resonance spectroscopy (EPR) is a technique based on the magnetic resonance between an unpaired electron and an external magnetic field. Due to the very short lifetime of radicals, EPR measurement is often used with spin-trap reagents. The reaction of a radical with the spin-trap reagent leads to the formation of a longer-lived spin adduct. EPR spectra were recorded with a Bruker ESP 500E spectrometer at room temperature. The following instrumental settings were employed for the measurements: central field: 3516 G; sweep width: 100 G; microwave frequency: 9.87 GHz; modulation frequency: 100 kHz; microwave power: 5.15 mW; scanning time: 84 s; number of scans: 6. Figure 13 gives EPR calibration performed using an aqueous solution of a stable radical, TEMPO, in concentrations ranging from 0–50 µM.
The spin trapping reagents, 5,5-dimethyl-1-pyrroline N-oxide (DMPO), 2,2,6,6-tetramethylpiperidine (TEMP), α-phenyl-N-tert-butylnitrone (PBN), 2-(4-Carboxyphenyl)−4,5-dihydro-4,4,5,5-tetramethyl-1H-imidazol-1-yloxy-3-oxide potassium salt (C-PTIO), D-Mannitol (OH* scavenger), and superoxide dismutase (superoxide anion scavenger) Sodium azide (NaN3) were purchased from Sigma-Aldrich.
Reactive oxygen species such as hydroxyl radical (•OH) superoxide anion (02 •−), singlet oxygen (1O2), nitric oxide radical (NO•) and others including hydrogen radical (H•) are presumed to be produced in the different media upon their exposure to plasma. To characterize their formation, the spin trapping reagents DMPO (252 mM), TEMP (2 mM), PBN (21.6 mM) and C-PTIO (833 µM) were added to the different samples immediately before plasma treatment. All samples were transferred in to glass capillary tube (50 µL) immediately after plasma exposure.
To confirm the formation of O2 •−, similar EPR–spin trapping experiments were performed in the presence of SOD (150 U/ml), enzyme catalyzing the conversion of O2 •− into H2O2 and O2 and directly related to the intensity of the DMPO-OH EPR signal. The DMPO-OH intensity was estimated directly from the half-height of the second peak of the quartet EPR spectra obtained for different media.
All measurements were performed in triplicate for each sample and the changes in the EPR signal were monitored for 2000 seconds after plasma exposure. Easyspin (MATLAB library) and WinSim2002 software were used for EPR spectra simulations [available online https://www.niehs.nih.gov/research/resources/software/tox-pharm/tools].
Hydrogen peroxide (H2O2) assay
H2O2 concentrations in PAM were quantified using a fluorometric Hydrogen Peroxidase Assay kit (Sigma–Aldrich Co., Ltd). This kit uses horseradish peroxidase and a red fluorescent peroxidase substrate (λex: 540 nm, λem: 590 nm) and allows quantification of H2O2 in a range of concentrations between 0 and 10 µM. PAM were diluted 1/50 before each measurement in order to achieve an adequate concentration of H2O2. Calibration curves (see Fig. 14) were plotted for the different liquid media used for the preparation of PAM from an initial 3% hydrogen peroxide solution to avoid any influence of medium absorption on the fluorescence measurements. Samples in black 96-well plates were analyzed using a CLARIOstar fluorescence plate reader (BMG LABTECH) at room temperature.
Detection of Nitrite/Nitrate anions (NO2−/NO3−)
NO2/NO3 concentrations in PAM were assayed with a colorimetric Nitrite/Nitrate Assay kit (Sigma–Aldrich Co., Ltd) using Griess reagent and nitrite reductase. The kit was initially planned for measurements in a range of concentrations between 0 and 100 µM of NO2 − and NO3 −. PAM were diluted 1/20 before each measurement in order to have an adequate concentration. Calibration curves (see Fig. 15) were plotted for each medium from initial solutions of NaNO2 and NaNO3 to take into account the influence of the medium absorption on the measurement. Sample absorbance at 540 nm was analyzed using a CLARIOstar plate reader (BMG LABTECH) at room temperature.
Mass spectrometry analysis
The LC/MS system was equipped with an HPLC chromatograph (HPLC Agilent 1100 series) and a triple quadrupole mass spectrometer (QTRAP Applied Biosystems). HPLC analyses were performed using a Waters X Bridge C18 (3.5 µm) column (2.1 × 150 mm), and a gradient elution starting with 5% acetonitrile and 95% ammonium acetate at a flow rate of 0.6 mL min−1 rising at 15 min a plateau corresponding to 50% acetonitrile and 50% ammonium acetate for 5 minutes. The mass spectrometer was equipped with an electrospray ion (ESI) source (turbo ion spray (TIS) and was operated in positive mode. Nitrogen served as auxiliary, collision gas, and nebulizer gas. The detection was scan mode with a step size of 0.1 atomic mass unit (amu) and a scan range of 50–500 amu. Mass chromatograms, i.e., representations of mass spectrometry data as chromatograms (the x-axis represents time and the y-axis represents signal intensity), were registered using different scan ranges.
The prepared concentration of each amino acids (tryptophan, tyrosine, methionine, arginine) was 0.2 mM in MilliQwater. Each solution was treated by He plasma at various time of exposure (0–240 s).
References 72
- 1.
Fridman, A. Plasma Chemistry, New York: Cambridge University Press (2008).
Not in our library
- 2.
Cooper M, et al. Decontamination of Surfaces From Extremophile Organisms Using Nonthermal Atmospheric-Pressure Plasmas. IEEE Trans. Plasma Sci. 2009;37:866-871.
Not in our library10.1109/tps.2008.2010618
- 3.
Sun P, et al. Tooth Whitening With Hydrogen Peroxide Assisted by a Direct-Current Cold Atmospheric-Pressure Air Plasma Microjet. IEEE Trans. Plasma Sci. 2010;38:1892-1896.
Not in our library10.1109/tps.2010.2066991
- 4.
Kalghati S, Friedman G, Fridman A, Clyne AM. Endothelial Cell Proliferation is Enhanced by Low Dose Non-Thermal Plasma Through Fibroblast Growth Factor-2 Release. Ann. Biomed. Engi. 2010;38:748-757.
Not in our library10.1007/s10439-009-9868-x
- 5.
Vandamme M, et al. ROS implication in a new antitumor strategy based on non-thermal plasma. Int. J. Cancer. 2012;130:2185-2194.
Not in our library10.1002/ijc.26252
- 6.
Isbary G, et al. A first prospective randomized controlled trial to decrease bacterial load using cold atmospheric argon plasma on chronic wounds in patients. Brit. J. Dermatol. 2010;163:78-82.
Not in our library10.1111/j.1365-2133.2010.09744.x
- 7.
Joshi SG, et al. Endothelial Cell Proliferation is Enhanced by Low Dose Non-Thermal Plasma Through Fibroblast Growth Factor-2 Release. Antimicrob. Agents Chem. 2011;55:1053-1062.
Not in our library10.1128/aac.01002-10
- 8.
- 9.
Rupf S, et al. Cold Atmospheric Plasma: methods of production and application in dentistry and oncology. J. Med. Microbil. 2010;59:206-212.
Not in our library10.1099/jmm.0.013714-0
- 10.
- 11.
Chang JW, et al. Non-thermal atmospheric pressure plasma induces apoptosis in oral cavity squamous cell carcinoma: Involvement of DNA-damage-triggering sub-G1 arrest via the ATM/p53 pathway. Arch. Biochem. Biophys. 2014;545:133-140.
Not in our library10.1016/j.abb.2014.01.022
- 12.
Utsumi F, et al. Selective cytotoxicity of indirect nonequilibrium atmospheric pressure plasma against ovarian clear-cell carcinoma. SpringerPlus. 2014;3:398.
Not in our library10.1186/2193-1801-3-398
- 13.
Adachi T, et al. Plasma-activated medium induces A549 cell injury via a spiral apoptotic cascade involving the mitochondrial-nuclear network. Free Radic. Biol. Med. 2015;79:28-44.
Not in our library10.1016/j.freeradbiomed.2014.11.014
- 14.
Hirst A, et al. Low-temperature plasma treatment induces DNA damage leading to necrotic cell death in primary prostate epithelial cells. Br. J. Cancer. 2015;112:1536-1545.
Not in our library10.1038/bjc.2015.113
- 15.
Plewa J-M, et al. Low temperature plasma-induced antiproliferative effects on Multicellular Tumor Spheroid. New J. Phys. 2014;16:043027.
Not in our library10.1088/1367-2630/16/4/043027
- 16.
Judée F, et al. Short and long time effects of low temperature Plasma Activated Media on 3D multicellular tumor spheroids. Sci. Rep. 2016;6:21421.
Not in our library10.1038/srep21421
- 17.
Ishaq M, Evans MD, Ostrikov K. Atmospheric pressure gas plasma-induced colorectal cancer cell death is mediated by Nox2-ASK1 apoptosis pathways and oxidative stress is mitigated by Srx-Nrf2 anti-oxidant system. Biochim. Bioph. Acta. 2014;1843:2827-2837.
Not in our library10.1016/j.bbamcr.2014.08.011
- 18.
Keidar M, et al. Cold Atmospheric Plasma in Cancer Therapy. Phys. Plasmas. 2013;20:057101.
Not in our library10.1063/1.4801516
- 19.
Kaushik N, Kumar N, Kim CH, Kaushik N, Choi EH. Dielectric Barrier Discharge Plasma Efficiently Delivers an Apoptotic Response in Human Monocytic Lymphom. Plasma Process. Polym. 2014;11:1175-1187.
Not in our library10.1002/ppap.201400102
- 20.
Judée F, Merbahi N, Yousfi M. Genotoxic and cytotoxic effects of plasma activated media on Multi-Cellular Tumor Spheroids. Plasma Med. 2016;6:15823.
Not in our library10.1038/srep21421
- 21.
Yan D, et al. Stabilizing the cold plasma-stimulated medium by regulating medium’s composition. Sci Rep. 2016;6:26016.
Not in our library10.1038/srep26016
- 22.
Weiss M, et al. Cold Atmospheric Plasma Treatment Induces Anti-Proliferative Effects in Prostate Cancer Cells by Redox and Apoptotic Signaling Pathways. PLos One. 2015;10:e0130350.
Not in our library10.1371/journal.pone.0130350
- 23.
Pei X, Lu Y, Wu S, Xiong Q, Lu X. A study on the temporally and spatially resolved OH radical distribution of a room-temperature atmospheric-pressure plasma jet by laser-induced fluorescence imaging. Plasma Sources Sci. Technol. 2013;22:025023.
Not in our library10.1088/0963-0252/22/2/025023
- 24.
Reuter S, et al. Atomic Oxygen in a Cold Argon Plasma Jet: TALIF Spectroscopy in Ambient Air with Modelling and Measurements of Ambient Species Diffusion. Plasma Sources Sci. technol. 2012;21:024005.
Not in our library10.1088/0963-0252/21/2/024005
- 25.
van Gessel A, van Grootel S, Bruggeman P. Atomic oxygen TALIF measurements in an atmospheric-pressure microwave plasma jet with in situ xenon calibration. Plasma Sources Sci. Technol. 2013;22:055010.
Not in our library10.1088/0963-0252/22/5/055010
- 26.
Park JY, et al. Study on optical emission analysis of AC air–water discharges under He, Ar and N2 environments. J.Phys. D Appl. Phys. 2006;39:3805-3813.
Not in our library10.1088/0022-3727/39/17/015
- 27.
Kanazawa S, Furuki T, Nakaji T, Akamine S, Ichiki R. Measurement of OH Radicals in Aqueous Solution Produced by Atmospheric-pressure LF Plasma Jet. Int. J. Plasma Env. Sci. Technol. 2012;6:166-171.
Not in our library
- 28.
Sahni M, Locke BR. Quantification of Hydroxyl Radicals Produced in Aqueous Phase Pulsed Electrical Discharge Reactors. Ind. Eng. Chem. Res. 2006;45:5819-5825.
Not in our library10.1021/ie0601504
- 29.
Tani A, et al. Free radicals induced in aqueous solution by non-contact atmospheric-pressure cold plasma. Appl.Phys. Lett. 2012;100:254103.
Not in our library10.1063/1.4729889
- 30.
Tahara M, Okubo M. Detection of free radicals produced by a pulsed electrohydraulic discharge using electron spin resonance. J. Electrostat. 2014;72:222-227.
Not in our library10.1016/j.elstat.2014.03.002
- 31.
Wu, H. et al. Reactive Oxygen Species in a Non-thermal Plasma Microjet and Water System: Generation, Conversion, and Contributions to Bacteria Inactivation-An Analysis by Electron Spin Resonance Spectroscopy. Plasma Process. Polym. 9, 201100065 (2012).
Not in our library
- 32.
Uchiyama H, et al. EPR-Spin Trapping and Flow Cytometric Studies of Free Radicals Generated Using Cold Atmospheric Argon Plasma and X-Ray Irradiation in Aqueous Solutions and Intracellular Milieu. Plos one. 2015;10:e0136956.
Not in our library10.1371/journal.pone.0136956
- 33.
Tresp H, Hammer MU, Winter J, Weltmann K-D, Reuter S. Quantitative detection of plasma-generated radicals in liquids by electron paramagnetic. J.Phys. D Appl. Phys. 2013;46:435401.
Not in our library10.1088/0022-3727/46/43/435401
- 34.
Tresp H, Hammer MU, Weltmann K-D, Reuter S. Effects of Atmosphere Composition and Liquid Type on Plasma-Generated Reactive Species in Biologically Relevant Solutions. Plasma Med. 2013;3:45-55.
Not in our library10.1615/plasmamed.2014009711
- 35.
Zhang Q, et al. Assessment of the roles of various inactivation agents in an argon-based direct current atmospheric pressure cold plasma jet. J, Appl, Phys. 2012;111:123305.
Not in our library10.1063/1.4730627
- 36.
Feng H, et al. A study of eukaryotic response mechanisms to atmospheric pressure cold plasma by using Saccharomyces cerevisiae single gene mutants. Appl. Phys. Lett. 2010;97:131501.
Not in our library10.1063/1.3491180
- 37.
Buettner GR. Spin Trapping: ESR parameters of spin adducts 1474 1528V. Free Rad. Biol. Med. 1987;3:259-303.
Not in our library10.1016/s0891-5849(87)80033-3
- 38.
Yusupov M, et al. Reactive molecular dynamics simulations of oxygen species in a liquid water layer of interest for plasma medicine. J Phys. D Appl. Phys. 2013;47:025205.
Not in our library10.1088/0022-3727/47/2/025205
- 39.
Tian W, Kushner MJ. Atmospheric pressure dielectric barrier discharges interacting with liquid covered tissue. J. Phys. D Appl. Phys. 2014;47:165201.
Not in our library10.1088/0022-3727/47/16/165201
- 40.
Gorbanev Y, O’Connell D, Checik V. Non thermal plasma in contact with water: The origin of species, 2016. Chem Eur J. 2016;22:3496-3505.
Not in our library10.1002/chem.201503771
- 41.
Xu G, Chance MR. Hydroxyl radical-mediated modification of proteins as probes for structural proteomics. Chem. Reviews. 2007;107:3514-3543.
Not in our library10.1021/cr0682047
- 42.
Neyts, E. C., Yusupov, M., Verlackt, C. C. & Bogaerts, A. Computer simulations of plasma–biomolecule and plasma–tissue interactions for a better insight in plasma medicine. J. Phys. D Appl. Phys. 29 (2014).
Not in our library
- 43.
Takai E, et al. Chemical modification of amino acids by atmospheric-pressure cold plasma in aqueous solution. J. Phys. D AppL. Phys. 2014;47:285403.
Not in our library10.1088/0022-3727/47/28/285403
- 44.
Reszka KJ, et al. Nitric oxide decreases the stability of DMPO spin adducts. Nitric Oxide. 2006;15:133-141.
Not in our library10.1016/j.niox.2006.03.004
- 45.
Arjunan, K. P. & Clyne, A. M. Hydroxyl Radical and Hydrogen Peroxide are Primarily Responsible for Dielectric Barrier Discharge Plasma-Induced Angiogenesis. Plasma Process. Polym. 8, 201100078 (2011).
Not in our library
- 46.
Bancirova M. Sodium azide as a specific quencher of singlet oxygenduring chemiluminescent detection by luminol and Cypridina luciferin analogues. Luminescence. 2011;26:685-688.
Not in our library10.1002/bio.1296
- 47.
Zang, L., Zhang, Z. & Misra, H. P. EPR studies of trapped singlet oxygen (O-1(2)) generated during photoirradiation of hypocrellin-a Photochem. Photobiol. 677–683 (1990).
Not in our library10.1111/j.1751-1097.1990.tb08666.x
- 48.
Foote, C. S. Quenching of singlet oxygen. In Singlet Oxygen (Edited by H. H. Wasserman and R. W. Murray), pp. 139–171. Academic Press, New York (1979)
Not in our library
- 49.
Kawasaki T, et al. Detection of reactive oxygen species supplied into the water bottom by atmospheric non-thermal plasma jet using iodine-starch reaction. J. Appl. Phys. 2015;54:086201.
Not in our library10.7567/jjap.54.086201
- 50.
Gracanin M, Hawkins CL, Pattison DI, Davies MJ. Singlet oxygen-mediated amino acid and protein oxidation: Formation of tryptophan peroxides and decomposition products. Free Rad. Biol. Med. 2009;47:92-102.
Not in our library10.1016/j.freeradbiomed.2009.04.015
- 51.
Zhou R, et al. Interaction of Atmsopheric-Pressure Air Microplasmas with Amino Acids as Fundamental Processes in Aqueous Solution. Plos One. 2016;11:e0155584.
Not in our library10.1371/journal.pone.0155584
- 52.
Roche M, Rondeau P, Ranjan Singh N, Tarnus E. & Bourdon, E. The antioxydant properties of serum albumin. FEBS Letters. 2008;582:1783-1787.
Not in our library10.1016/j.febslet.2008.04.057
- 53.
Azma T, Fujii K, Yuge O. Reaction between imidazolineoxil N-oxide (carboxy-ptio) and nitric oxide released from cultured endothelial cells: Quantitative measurement of nitric oxide by ESR spectrometry. Pharmacology Letters. 1994;54:185-190.
Not in our library10.1016/0024-3205(94)90166-x
- 54.
Akaike T, et al. Antagonistic action of imidazolineoxyl N-oxides against endothelium-derived relaxing factor/.bul.NO (nitric oxide) through a radical reaction. Biochemistry. 1993;32:827-832.
Not in our library10.1021/bi00054a013
- 55.
Gorbanev Y, Stehling N, O’Connell D, Chechik V. reaction of nitroxide radicals in aqueous solutions exposed to non-thermal plasma: limitations of spin trapping of the plasma induced species. Plasma Sources Sci. Technol. 2016;25:055017.
Not in our library10.1088/0963-0252/25/5/055017
- 56.
Puac N, et al. Sterilization of bacteria suspensions and identification of radicals deposited during plasma treatment. Open Chem. 2014;13:332-338.
Not in our library10.1515/chem-2015-0041
- 57.
Dobrynin D, Fridman A, Starikovskiy AY. Reactive Oxygen and Nitrogen Species Production and Delivery Into Liquid Media by Microsecond Thermal Spark-Discharge Plasma Jet. IEEE Trans. Plasma Sci. 2012;40:2163-2171.
Not in our library10.1109/tps.2012.2204780
- 58.
Takamatsu T, et al. Bacterial Inactivation in Liquids Using Multi-Gas Plasma. Plasma Med. 2012;2:237-247.
Not in our library10.1615/plasmamed.2014010792
- 59.
Lukes P, Dolezalova E, Sisrova I, Clupek M. Aqueous-phase chemistry and bactericidal effects from an air plasma discharge plasma in contact with water: evidence for the formation of peroxynitrite through a pseudo-second-order post discharge reaction H2O2 and HNO2. Plasma Sources Sci. Technol. 2014;23:015019.
Not in our library10.1088/0963-0252/23/1/015019
- 60.
Kojtari A, et al. Chemistry for Antimicrobial Properties of Water Treated With Non-Equilibrium Plasma. Nanomed. Biother. Discovery. 2013;04:1000120.
Not in our library
- 61.
Machala Z, et al. Formation of ROS and RNS in Water Electro-Sprayed through Transient Spark Discharge in Air and their Bactericidal Effects. Plasma Processes Polym. 2013;10:649-659.
Not in our library10.1002/ppap.201200113
- 62.
Girard F, et al. Formation of reactive nitrogen species including peroxynitrite in physiological buffer exposed to cold atmospheric plasma. RSC Adv. 2016;6:78457-78467.
Not in our library10.1039/c6ra12791f
- 63.
Toledo JC, Augusto O. Connecting the chemical and biological properties of nitric oxide. Chem Res Toxicol. 2012;25:975-989.
Not in our library10.1021/tx300042g
- 64.
Mannick JB, Schonhoff CM. Nitrosylation: the next phosphorylation? Arch. Biochem. Biophys. 2002;408:1-6.
Not in our library10.1016/s0003-9861(02)00490-3
- 65.
Ischiropoulos H. Biological selectivity and functional aspects of protein tyrosine nitration. Biochem. Biophys. Res. Com. 2003;305:776-783.
Not in our library10.1016/s0006-291x(03)00814-3
- 66.
Liu DX, et al. Aqueous reactive species induced by a surface air discharge: Heterogeneous mass transfer and liquid chemistry pathways. Sci. Rep. 2016;6:23737.
Not in our library10.1038/srep23737
- 67.
Baret A, Emerit I. Variation of superoxide dismutase levels in fetal calf serum. Mut. Res. 1983;121:293-297.
Not in our library10.1016/0165-7992(83)90217-8
- 68.
Torres J, Wilson MT. The reactions of copper proteins with nitric oxide. Biochimica et Biophysica Acta. 1999;1411:310-322.
Not in our library10.1016/s0005-2728(99)00022-5
- 69.
Lundberg JO, Weitzberg E, Gladwin MT. The nitrate–nitrite–nitric oxide pathway in physiology and therapeutics. Nat. Rev. Drug Discov. 2008;7:156-167.
Not in our library10.1038/nrd2466
- 70.
- 71.
Yousfi M, Eichwald O, Merbahi N, Jomaa N. Analysis of ionization wave dynamics in low-temperature plasma jets from fluid modeling supported by experimental investigations. Plasma Sources Sci Technol. 2012;21:045003.
Not in our library10.1088/0963-0252/21/4/045003
- 72.
Stoll S, Schweiger A. EasySpin, a comprehensive software package for spectral simulation and analysis in EPR. J. Magn. Reson. 2006;178:42-55.
Not in our library10.1016/j.jmr.2005.08.013
Cited by papers we hold 1
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.