Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty

T.L. Nicholson, S.L. Campbell, R.B. Hutson and 9 more

Nature Communications · 2015 · arXiv licence (no reuse)

doi:10.1038/ncomms7896

Abstract

The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. Here we take an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87 Sr optical lattice clock now achieves fractional stability of 2.2 × 10 −16 at 1 s. With this improved stability, we perform a new accuracy evaluation of our clock, reducing many systematic uncertainties that limited our previous measurements, such as those in the lattice ac Stark shift, the atoms’ thermal environment and the atomic response to room-temperature blackbody radiation. Our combined measurements have reduced the total uncertainty of the JILA Sr clock to 2.1 × 10 −18 in fractional frequency units.

Full text

Its licence does not allow us to show the full text. Read it at PubMed Central:

Read at PubMed Central

References 50

  1. 1.

    Bloom B. J. et al. An optical lattice clock with accuracy and stability at the 10−18 level. Nature 506, 71–75 (2014 ).

    Not in our library10.1038/nature12941

  2. 2.

    Chou C. W., Hume D. B., Koelemeij J. C. J., Wineland D. J. & Rosenband T. Frequency comparison of two high-accuracy Al+ optical clocks. Phys. Rev. Lett. 104, 070802 (2010 ).

    Not in our library10.1103/physrevlett.104.070802

  3. 3.

    Hinkley N. et al. An atomic clock with 10−18 instability. Science 341, 1215–1218 (2013 ).

    Not in our library10.1126/science.1240420

  4. 4.

    Madej A. A., Dubé P., Zhou Z., Bernard J. E. & Gertsvolf M. 88Sr+ 445-THz Single-ion reference at the 10−17 level via control and cancellation of systematic uncertainties and its measurement against the SI second. Phys. Rev. Lett. 109, 203002 (2012 ).

    Not in our library10.1103/physrevlett.109.203002

  5. 5.

    Ushijima I., Takamoto M., Das M., Ohkubo T. & Katori H. Cryogenic optical lattice clocks. Nat. Photonics 9, 185–189 (2015 ).

    Not in our library

  6. 6.

    Wineland D. J. Nobel Lecture: superposition, entanglement, and raising Schrödinger's cat. Rev. Mod. Phys. 85, 1103–1114 (2013 ).

    Not in our library10.1002/anie.201303404

  7. 7.

    Haroche S. Nobel Lecture: controlling photons in a box and exploring the quantum to classical boundary. Rev. Mod. Phys. 85, 1083–1102 (2013 ).

    Not in our library10.1002/anie.201302971

  8. 8.

    Zhang X. et al. Spectroscopic observation of SU(N)-symmetric interactions in Sr orbital magnetism. Science 345, 1467–1473 (2014 ).

    Not in our library10.1126/science.1254978

  9. 9.

    Scazza F. et al. Observation of two-orbital spin-exchange interactions with ultracold SU(N)-symmetric fermions. Nat. Phys. 10, 779–784 (2014 ).

    Not in our library

  10. 10.

    Godun R. M. et al. Frequency ratio of two optical clock transitions in Yb+ and constraints on the time variation of fundamental constants. Phys. Rev. Lett. 113, 210801 (2014 ).

    Not in our library10.1103/physrevlett.113.210801

  11. 11.

    Huntemann N. et al. Improved limit on a temporal variation of mp/me from comparisons of Yb+ and Cs atomic clocks. Phys. Rev. Lett. 113, 210802 (2014 ).

    Not in our library10.1103/physrevlett.113.210802

  12. 12.

    Cacciapuoti L. & Salomon C. Space clocks and fundamental tests: The ACES experiment. Eur. Phys. J. Spec. Top. 172, 57–68 (2009 ).

    Not in our library

  13. 13.

    Kessler T. et al. A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity. Nat. Photonics 6, 687–692 (2012 ).

    Not in our library

  14. 14.

    Bishof M., Zhang X., Martin M. J. & Ye J. Optical spectrum analyzer with quantum-limited noise floor. Phys. Rev. Lett. 111, 093604 (2013 ).

    Not in our library10.1103/physrevlett.111.093604

  15. 15.

    Schmidt P. et al. Spectroscopy using quantum logic. Science 85, 749–752 (2005 ).

    Not in our library10.1126/science.1114375

  16. 16.

    Ye J., Kimble H. J. & Katori H. Quantum state engineering and precision metrology using state-insensitive light traps. Science 320, 1734–1738 (2008 ).

    Not in our library10.1126/science.1148259

  17. 17.

    Boyd M. M. et al. Optical atomic coherence at the 1-second time scale. Science 314, 1430–1433 (2006 ).

    Not in our library10.1126/science.1133732

  18. 18.

    Martin M. et al. A quantum many-body spin system in an optical lattice clock. Science 341, 632–637 (2013 ).

    Not in our library10.1126/science.1236929

  19. 19.

    Dick J. G. In Proc 19th Precise Time Time Interval Meet. 133–147 (1987 ).

    Not in our library

  20. 20.

    Itano W. et al. Quantum projection noise: Population fluctuations in two-level systems. Phys. Rev. A 47, 3554 (1993 ).

    Not in our library10.1103/physreva.47.3554

  21. 21.

    Nicholson T. L. et al. Comparison of two independent Sr optical clocks with 1 × 10−17 stability at 103 s. Phys. Rev. Lett. 109, 230801 (2012 ).

    Not in our library10.1103/physrevlett.109.230801

  22. 22.

    Boyd M. et al. 87Sr lattice clock with inaccuracy below 10−15. Phys. Rev. Lett. 98, 083002 (2007 ).

    Not in our library10.1103/physrevlett.98.083002

  23. 23.

    Katori H. In Proc. 6th Symp. Freq. Stand. Metrol. Univ. St. Andrews, Fife, Scotl 323–330 (2002 ).

    Not in our library

  24. 24.

    Kimble H. J. In Proc. XIV Int. Conf. Laser Spectrosc. 80–89 (1999 ).

    Not in our library

  25. 25.

    Westergaard P. et al. Lattice-induced frequency shifts in Sr optical lattice clocks at the 10−17 level. Phys. Rev. Lett. 106, 210801 (2011 ).

    Not in our library10.1103/physrevlett.106.210801

  26. 26.

    Takamoto M. et al. Improved frequency measurement of a one-dimensional optical lattice clock with a spin-polarized fermionic 87Sr isotope. J. Phys. Soc. Jpn 75, 104302 (2006 ).

    Not in our library

  27. 27.

    Falke S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014 ).

    Not in our library

  28. 28.

    Mcdonald M., Mcguyer B. H., Iwata G. Z. & Zelevinsky T. Thermometry via light shifts in optical lattices. Phys. Rev. Lett. 114, 023001 (2015 ).

    Not in our library10.1103/physrevlett.114.023001

  29. 29.

    Lodewyck J., Zawada M., Lorini L., Gurov M. & Lemonde P. Observation and cancellation of a perturbing dc Stark shift in strontium optical lattice clocks. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 59, 411–415 (2012 ).

    Not in our library10.1109/tuffc.2012.2209

  30. 30.

    Safronova M. S., Porsev S. G., Safronova U. I., Kozlov M. G. & Clark C. W. Blackbody-radiation shift in the Sr optical atomic clock. Phys. Rev. A 87, 012509 (2013 ).

    Not in our library

  31. 31.

    Porsev S. & Derevianko A. Multipolar theory of blackbody radiation shift of atomic energy levels and its implications for optical lattice clocks. Phys. Rev. A 74, 020502 (2006 ).

    Not in our library

  32. 32.

    Middelmann T., Falke S., Lisdat C. & Sterr U. High accuracy correction of blackbody radiation shift in an optical lattice clock. Phys. Rev. Lett. 109, 263004 (2012 ).

    Not in our library10.1103/physrevlett.109.263004

  33. 33.

    Boguhn D. & Koepke M. Typical R(T90) characteristics of platinum thin-film resistance thermometers in the temperature range from −50 °C to +660 °C. Int. J. Thermophys. 32, 2379–2387 (2011 ).

    Not in our library

  34. 34.

    Beloy K. et al. Atomic clock with 1 × 10−18 room-temperature blackbody Stark uncertainty. Phys. Rev. Lett. 113, 260801 (2014 ).

    Not in our library10.1103/physrevlett.113.260801

  35. 35.

    Beloy K. et al. Determination of the 5d6s3D1 state lifetime and blackbody-radiation clock shift in Yb. Phys. Rev. A 86, 051404(R) (2012 ).

    Not in our library

  36. 36.

    Dick G., Prestage J., Greenhall C. & Maleki L. In Proc. 22nd Precise Time Time Interval Meet. 487–508 (1990 ).

    Not in our library

  37. 37.

    Biedermann G. W. et al. Zero-dead-time operation of interleaved atomic clocks. Phys. Rev. Lett. 111, 170802 (2013 ).

    Not in our library10.1103/physrevlett.111.170802

  38. 38.

    Cole G. D., Zhang W., Martin M. J., Ye J. & Aspelmeyer M. Tenfold reduction of Brownian noise in high-reflectivity optical coatings. Nat. Photonics 7, 644–650 (2013 ).

    Not in our library

  39. 39.

    Kómár P. et al. A quantum network of clocks. Nat. Phys. 10, 582–587 (2014 ).

    Not in our library

  40. 40.

    Bohnet J. G. et al. Reduced spin measurement back-action for a phase sensitivity ten times beyond the standard quantum limit. Nat. Photonics 8, 731–736 (2014 ).

    Not in our library

All 50 references

Cited by papers we hold 1

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.