Skip to content
naulon

No retraction, correction or concern found when last checked on Oct 20, 2026.

Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues

Stratis Tzoumas, Antonio Nunes, Ivan Olefir and 6 more

Nature Communications · 2016 · CC BY

doi:10.1038/ncomms12121

Abstract

Light propagating in tissue attains a spectrum that varies with location due to wavelength-dependent fluence attenuation, an effect that causes spectral corruption. Spectral corruption has limited the quantification accuracy of optical and optoacoustic spectroscopic methods, and impeded the goal of imaging blood oxygen saturation (sO 2 ) deep in tissues; a critical goal for the assessment of oxygenation in physiological processes and disease. Here we describe light fluence in the spectral domain and introduce eigenspectra multispectral optoacoustic tomography (eMSOT) to account for wavelength-dependent light attenuation, and estimate blood sO 2 within deep tissue. We validate eMSOT in simulations, phantoms and animal measurements and spatially resolve sO 2 in muscle and tumours, validating our measurements with histology data. eMSOT shows substantial sO 2 accuracy enhancement over previous optoacoustic methods, potentially serving as a valuable tool for imaging tissue pathophysiology.

Full text

Its licence does not allow us to show the full text. Read it at PubMed Central:

Read at PubMed Central

References 31

  1. 1.

    Vaupel P. & Harrison L. Tumor hypoxia: causative factors, compensatory mechanisms, and cellular response. Oncologist 9, 4–9 (2004 ).

    Not in our library10.1634/theoncologist.9-90005-4

  2. 2.

    Serganova I., Humm J., Ling C. & Blasberg R. Tumor hypoxia imaging. Clin. Cancer Res. 12, 5260–5264 (2006 ).

    Not in our library10.1158/1078-0432.ccr-06-0517

  3. 3.

    Elas M. et al. Quantitative tumor oxymetric images from 4D electron paramagnetic resonance imaging (EPRI): methodology and comparison with blood oxygen level-dependent (BOLD) MRI. Magn. Reson. Med. 49, 682–691 (2003 ).

    Not in our library10.1002/mrm.10408

  4. 4.

    Ogawa S., Lee T.-M., Kay A. R. & Tank D. W. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc. Natl. Acad. Sci. 87, 9868–9872 (1990 ).

    Not in our library10.1073/pnas.87.24.9868

  5. 5.

    Klassen L. M. & Menon R. S. NMR simulation analysis of statistical effects on quantifying cerebrovascular parameters. Biophys. J. 92, 1014–1021 (2007 ).

    Not in our library10.1529/biophysj.106.087965

  6. 6.

    Rumsey W. L., Vanderkooi J. M. & Wilson D. F. Imaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue. Science 241, 1649–1651 (1988 ).

    Not in our library10.1126/science.241.4873.1649

  7. 7.

    Zhang H. F., Maslov K., Stoica G. & Wang L. V. Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging. Nat. Biotechnol. 24, 848–851 (2006 ).

    Not in our library10.1038/nbt1220

  8. 8.

    Durduran T., Choe R., Baker W. & Yodh A. Diffuse optics for tissue monitoring and tomography. Rep. Prog. Phys. 73, 076701 (2010 ).

    Not in our library10.1088/0034-4885/73/7/076701

  9. 9.

    Eggebrecht A. T. et al. Mapping distributed brain function and networks with diffuse optical tomography. Nat. Photonics 8, 448–454 (2014 ).

    Not in our library10.1038/nphoton.2014.107

  10. 10.

    Ntziachristos V. Going deeper than microscopy: the optical imaging frontier in biology. Nat. Methods 7, 603–614 (2010 ).

    Not in our library10.1038/nmeth.1483

  11. 11.

    Mohajerani P., Tzoumas S., Rosenthal A. & Ntziachristos V. Optical and optoacoustic model-based tomography: theory and current challenges for deep tissue imaging of optical contrast. Signal Process. Mag. IEEE 32, 88–100 (2015 ).

    Not in our library

  12. 12.

    Maslov K., Zhang H. F. & Wang L. V. Effects of wavelength-dependent fluence attenuation on the noninvasive photoacoustic imaging of hemoglobin oxygen saturation in subcutaneous vasculature in vivo. Inverse Probl. 23, S113 (2007 ).

    Not in our library

  13. 13.

    Cox B., Laufer J. G., Arridge S. R. & Beard P. C. Quantitative spectroscopic photoacoustic imaging: a review. J. Biomed. Opt. 17, 61202 (2012 ).

    Not in our library10.1117/1.jbo.17.6.061202

  14. 14.

    Arridge S. R. & Hebden J. C. Optical imaging in medicine: II. modelling and reconstruction. Phys. Med. Biol. 42, 841 (1997 ).

    Not in our library10.1088/0031-9155/42/5/008

  15. 15.

    Li M.-L. et al. Simultaneous molecular and hypoxia imaging of brain tumors in vivo using spectroscopic photoacoustic tomography. Proc. IEEE 96, 481–489 (2008 ).

    Not in our library

  16. 16.

    Gerling M. et al. Real-time assessment of tissue hypoxia in vivo with combined photoacoustics and high-frequency ultrasound. Theranostics 4, 604 (2014 ).

    Not in our library10.7150/thno.7996

  17. 17.

    Tsai A. G., Johnson P. C. & Intaglietta M. Oxygen gradients in the microcirculation. Physiol. Rev. 83, 933–963 (2003 ).

    Not in our library10.1152/physrev.00034.2002

  18. 18.

    Mesquita R. C. et al. Hemodynamic and metabolic diffuse optical monitoring in a mouse model of hindlimb ischemia. Biomed. Opt. Express 1, 1173–1187 (2010 ).

    Not in our library10.1364/boe.1.001173

  19. 19.
  20. 20.

    Swain D. P. & Pittman R. N. Oxygen exchange in the microcirculation of hamster retractor muscle. Am. J. Physiol. 256, H247–H255 (1989 ).

    Not in our library10.1152/ajpheart.1989.256.1.h247

  21. 21.

    Tsai A. G., Cabrales P., Winslow R. M. & Intaglietta M. Microvascular oxygen distribution in awake hamster window chamber model during hyperoxia. Am. J. Physiol. 285, H1537–H1545 (2003 ).

    Not in our library10.1152/ajpheart.00176.2003

  22. 22.

    Stein J., Ellis C. & Ellsworth M. Relationship between capillary and systemic venous PO2 during nonhypoxic and hypoxic ventilation. Am. J. Physiol. 265, H537–H542 (1993 ).

    Not in our library10.1152/ajpheart.1993.265.2.h537

  23. 23.

    Smith K., Hill S., Begg A. & Denekamp J. Validation of the fluorescent dye Hoechst 33342 as a vascular space marker in tumours. Br. J. Cancer 57, 247–253 (1988 ).

    Not in our library10.1038/bjc.1988.54

  24. 24.

    Varia M. A. et al. Pimonidazole: a novel hypoxia marker for complementary study of tumor hypoxia and cell proliferation in cervical carcinoma. Gynecol. Oncol. 71, 270–277 (1998 ).

    Not in our library10.1006/gyno.1998.5163

  25. 25.

    Buehler A., Kacprowicz M., Taruttis A. & Ntziachristos V. Real-time handheld multispectral optoacoustic imaging. Opt. Lett. 38, 1404–1406 (2013 ).

    Not in our library10.1364/ol.38.001404

  26. 26.

    Taruttis A. & Ntziachristos V. Advances in real-time multispectral optoacoustic imaging and its applications. Nat. Photon. 9, 219–227 (2015 ).

    Not in our library

  27. 27.

    Boas D. A. et al. The accuracy of near infrared spectroscopy and imaging during focal changes in cerebral hemodynamics. Neuroimage 13, 76–90 (2001 ).

    Not in our library10.1006/nimg.2000.0674

  28. 28.

    Razansky D., Buehler A. & Ntziachristos V. Volumetric real-time multispectral optoacoustic tomography of biomarkers. Nat. Protoc. 6, 1121–1129 (2011 ).

    Not in our library10.1038/nprot.2011.351

  29. 29.

    Rosenthal A., Razansky D. & Ntziachristos V. Fast semi-analytical model-based acoustic inversion for quantitative optoacoustic tomography. IEEE Trans. Med. Imaging 29, 1275–1285 (2010 ).

    Not in our library10.1109/tmi.2010.2044584

  30. 30.

    Dean-Ben X. L., Ntziachristos V. & Razansky D. Acceleration of optoacoustic model-based reconstruction using angular image discretization. IEEE Trans. Med. Imaging 31, 1154–1162 (2012 ).

    Not in our library10.1109/tmi.2012.2187460

  31. 31.

    Briely-Sabo K. & Bjornerud A. Accurate de-oxygenation of ex vivo whole blood using sodium dithionite. in Proc. Intl. Sot. Mag. Reson. Med. 8, 2025 (2000 ).

    Not in our library

Cited by papers we hold 4

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.