Abstract

Fast-scan cyclic voltammetry (FSCV) has been used for over 20 years to study rapid neurotransmission in awake and behaving animals. These experiments were first carried out with carbon-fiber microelectrodes (CFMs) encased in borosilicate glass, which can be inserted into the brain through micromanipulators and guide cannulas. More recently, chronically implantable CFMs constructed with small diameter fused-silica have been introduced. These electrodes can be affixed in the brain with minimal tissue response, which permits longitudinal measurements of neurotransmission in single recording locations during behavior. Both electrode designs have been used to make novel discoveries in the fields of neurobiology, behavioral neuroscience, and psychopharmacology. The purpose of this Review is to address important considerations for the use of FSCV to study neurotransmitters in awake and behaving animals, with a focus on measurements of striatal dopamine. Common issues concerning experimental design, data collection, and calibration are addressed. When necessary, differences between the two methodologies (acute vs chronic recordings) are discussed. The topics raised in this Review are particularly important as the field moves beyond dopamine toward new neurochemicals and brain regions.

Shown for reading. Its publisher allows quoting it, not republishing it.

References 158

  1. 1.

    Nieoullon A, Cheramy A, Glowinski J. Nigral and striatal dopamine release under sensory stimuli. Nature. 1977;269:340-342.

    Not in our library10.1038/269340a0

  2. 2.

    Cheramy A, Leviel V, Glowinski J. Dendritic release of dopamine in the substantia nigra. Nature. 1981;289:537-542.

    Not in our library10.1038/289537a0

  3. 3.

    Delgado JM, DeFeudis FV, Roth RH, Ryugo DK, Mitruka BM. Dialytrode for long term intracerebral perfusion in awake monkeys. Arch Int Pharmacodyn Ther. 1972;198:9-21.

    Not in our library

  4. 4.

    Ungerstedt U, Pycock C. Functional correlates of dopamine neurotransmission. Bull Schweiz Akad Med Wiss. 1974;30:44-55.

    Not in our library

  5. 5.

    Zetterstrom T, Sharp T, Marsden CA, Ungerstedt U. In vivo measurement of dopamine and its metabolites by intracerebral dialysis: changes after d-amphetamine. J Neurochem. 1983;41:1769-1773.

    Not in our library10.1111/j.1471-4159.1983.tb00893.x

  6. 6.

    Sharp T, Zetterstrom T, Ungerstedt U. An in vivo study of dopamine release and metabolism in rat brain regions using intracerebral dialysis. J Neurochem. 1986;47:113-122.

    Not in our library10.1111/j.1471-4159.1986.tb02838.x

  7. 7.

    Zetterstrom T, Brundin P, Gage FH, Sharp T, Isacson O, Dunnett SB, Ungestedt U, Bjorklund A. In vivo measurement of spontaneous release and metabolism of dopamine from intrastriatal nigral grafts using intracerebral dialysis. Brain Res. 1986;362:344-349.

    Not in our library10.1016/0006-8993(86)90460-9

  8. 8.

    Pettit HO, Justice JB. Dopamine in the nucleus accumbens during cocaine self-administration as studied by in vivo microdialysis. Pharmacol, Biochem Behav. 1989;34:899-904.

    Not in our library10.1016/0091-3057(89)90291-8

  9. 9.

    Wang M, Roman GT, Schultz K, Jennings C, Kennedy RT. Improved temporal resolution for in vivo microdialysis byusing segmented flow. Anal Chem. 2008;80:5607-5615.

    Not in our library10.1021/ac800622s

  10. 10.

    Wang M, Slaney T, Mabrouk O, Kennedy RT. Collection of nanoliter microdialysate fractions in plugs for off-line in vivo chemical monitoring with up to 2 s temporal resolution. J Neurosci Methods. 2010;190:39-48.

    Not in our library10.1016/j.jneumeth.2010.04.023

  11. 11.

    Harstad RK, Bowser MT. High-Speed Microdialysis-Capillary Electrophoresis Assays for Measuring Branched Chain Amino Acid Uptake in 3T3-L1 cells. Anal Chem. 2016;88:8115-8122.

    Not in our library10.1021/acs.analchem.6b01846

  12. 12.

    Saylor RA, Lunte SM. A review of microdialysis coupled to microchip electrophoresis for monitoring biological events. J Chromatogr A. 2015;1382:48-64.

    Not in our library10.1016/j.chroma.2014.12.086

  13. 13.

    Hawley MD, Tatawawadi SV, Piekarski S, Adams RN. Electrochemical studies of the oxidation pathways of catecholamines. J Am Chem Soc. 1967;89:447-450.

    Not in our library10.1021/ja00978a051

  14. 14.

    Refshauge C, Kissinger PT, Dreiling R, Blank L, Freeman R, Adams RN. New high performance liquid chromatographic analysis of brain catecholamines. Life Sci. 1974;14:311-322.

    Not in our library10.1016/0024-3205(74)90061-7

  15. 15.

    Kissinger PT, Hart JB, Adams RN. Voltammetry in brain tissue–a new neurophysiological measurement. Brain Res. 1973;55:209-213.

    Not in our library10.1016/0006-8993(73)90503-9

  16. 16.

    Schenk JO, Miller E, Rice ME, Adams RN. Chronoamperometry in brain slices: quantitative evaluations of in vivo electrochemistry. Brain Res. 1983;277:1-8.

    Not in our library10.1016/0006-8993(83)90901-0

  17. 17.

    Gonon F, Buda M, Cespuglio R, Jouvet M, Pujol JF. In vivo electrochemical detection of catechols in the neostriatum of anaesthetized rats: dopamine or DOPAC? Nature. 1980;286:902-904.

    Not in our library10.1038/286902a0

  18. 18.

    Huff R, Adams RN, Rutledge CO. Amphetamine dose-dependent changes of in vivo electrochemical signals in rat caudate. Brain Res. 1979;173:369-372.

    Not in our library10.1016/0006-8993(79)90640-1

  19. 19.

    Wightman RM, May LJ, Michael AC. Detection of dopamine dynamics in the brain. Anal Chem. 1988;60:769A-779A.

    Not in our library10.1021/ac00164a001

  20. 20.

    Gratton A, Wise RA. Drug- and behavior-associated changes in dopamine-related electrochemical signals during intravenous cocaine self-administration in rats. J Neurosci. 1994;14:4130-4146.

    Not in our library10.1523/jneurosci.14-07-04130.1994

  21. 21.

    Kuhr WG, Ewing AG, Caudill WL, Wightman RM. Monitoring the stimulated release of dopamine with in vivo voltammetry. I: Characterization of the response observed in the caudate nucleus of the rat. J Neurochem. 1984;43:560-569.

    Not in our library10.1111/j.1471-4159.1984.tb00935.x

  22. 22.

    Marsden CA, Joseph MH, Kruk ZL, Maidment NT, O'Neill RD, Schenk JO, Stamford JA. In vivo voltammetry–present electrodes and methods. Neuroscience. 1988;25:389-400.

    Not in our library10.1016/0306-4522(88)90247-3

  23. 23.

    Phillips PEM, Wightman RM. Critical guidelines for validation of the selectivity of in-vivo chemical microsensors. TrAC, Trends Anal Chem. 2003;22:509-514.

    Not in our library

  24. 24.

    Ewing AG, Bigelow JC, Wightman RM. Direct in vivo monitoring of dopamine released from two striatal compartments in the rat. Science. 1983;221:169-171.

    Not in our library10.1126/science.6857277

  25. 25.

    Stamford JA, Kruk ZL, Millar J, Wightman RM. Striatal dopamine uptake in the rat: in vivo analysis by fast cyclic voltammetry. Neurosci Lett. 1984;51:133-138.

    Not in our library10.1016/0304-3940(84)90274-x

  26. 26.

    Baur JE, Kristensen EW, May LJ, Wiedemann DJ, Wightman RM. Fast-scan voltammetry of biogenic amines. Anal Chem. 1988;60:1268-1272.

    Not in our library10.1021/ac00164a006

  27. 27.

    Heien ML, Phillips PE, Stuber GD, Seipel AT, Wightman RM. Overoxidation of carbon-fiber microelectrodes enhances dopamine adsorption and increases sensitivity. Analyst. 2003;128:1413-1419.

    Not in our library10.1039/b307024g

  28. 28.

    Heien ML, Johnson MA, Wightman RM. Resolving neurotransmitters detected by fast-scan cyclic voltammetry. Anal Chem. 2004;76:5697-5704.

    Not in our library10.1021/ac0491509

  29. 29.

    Heien ML, Khan AS, Ariansen JL, Cheer JF, Phillips PE, Wassum KM, Wightman RM. Real-time measurement of dopamine fluctuations after cocaine in the brain of behaving rats. Proc Natl Acad Sci U S A. 2005;102:10023-10028.

    Not in our library10.1073/pnas.0504657102

  30. 30.

    Ponchon JL, Cespuglio R, Gonon F, Jouvet M, Pujol JF. Normal pulse polarography with carbon fiber electrodes for in vitro and in vivo determination of catecholamines. Anal Chem. 1979;51:1483-1486.

    Not in our library10.1021/ac50045a030

  31. 31.

    Armstrong-James M, Millar J. Carbon fibre microelectrodes. J Neurosci Methods. 1979;1:279-287.

    Not in our library10.1016/0165-0270(79)90039-6

  32. 32.

    Wightman RM. Microvoltammetric Electrodes. Anal Chem. 1981;53:1125A-1134A.

    Not in our library10.1021/ac00232a791

  33. 33.

    Peters JL, Miner LH, Michael AC, Sesack SR. Ultrastructure at carbon fiber microelectrode implantation sites after acute voltammetric measurements in the striatum of anesthetized rats. J Neurosci Methods. 2004;137:9-23.

    Not in our library10.1016/j.jneumeth.2004.02.006

  34. 34.

    Kozai TD, Jaquins-Gerstl AS, Vazquez AL, Michael AC, Cui XT. Brain tissue responses to neural implants impact signal sensitivity and intervention strategies. ACS Chem Neurosci. 2015;6:48-67.

    Not in our library10.1021/cn500256e

  35. 35.

    Gerhardt GA, Oke AF, Nagy G, Moghaddam B, Adams RN. Nafion-coated electrodes with high selectivity for CNS electrochemistry. Brain Res. 1984;290:390-395.

    Not in our library10.1016/0006-8993(84)90963-6

  36. 36.

    Swamy BE, Venton BJ. Carbon nanotube-modified microelectrodes for simultaneous detection of dopamine and serotonin in vivo. Analyst. 2007;132:876-884.

    Not in our library10.1039/b705552h

  37. 37.

    Singh YS, Sawarynski LE, Dabiri PD, Choi WR, Andrews AM. Head-to-head comparisons of carbon fiber microelectrode coatings for sensitive and selective neurotransmitter detection by voltammetry. Anal Chem. 2011;83:6658-6666.

    Not in our library10.1021/ac2011729

  38. 38.

    Schmidt AC, Wang X, Zhu Y, Sombers LA. Carbon nanotube yarn electrodes for enhanced detection of neuro-transmitter dynamics in live brain tissue. ACS Nano. 2013;7:7864-7873.

    Not in our library10.1021/nn402857u

  39. 39.

    Vreeland RF, Atcherley CW, Russell WS, Xie JY, Lu D, Laude ND, Porreca F, Heien ML. Biocompatible PEDOT:Nafion composite electrode coatings for selective detection of neurotransmitters in vivo. Anal Chem. 2015;87:2600-2607.

    Not in our library10.1021/ac502165f

  40. 40.

    Wightman RM, Amatorh C, Engstrom RC, Hale PD, Kristensen EW, Kuhr WG, May LJ. Real-time characterization of dopamine overflow and uptake in the rat striatum. Neuroscience. 1988;25:513-523.

    Not in our library10.1016/0306-4522(88)90255-2

All 158 references

Cited by papers we hold 1

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.