High-sensitivity troponin in the evaluation of patients with suspected acute coronary syndrome: a stepped-wedge, cluster-randomised controlled trial

Anoop S V Shah, Atul Anand, Fiona E Strachan and 53 more

The Lancet · 2018 · Randomised trial · CC BY

doi:10.1016/s0140-6736(18)31923-8

Abstract

Background. High-sensitivity cardiac troponin assays permit use of lower thresholds for the diagnosis of myocardial infarction, but whether this improves clinical outcomes is unknown. We aimed to determine whether the introduction of a high-sensitivity cardiac troponin I (hs-cTnI) assay with a sex-specific 99th centile diagnostic threshold would reduce subsequent myocardial infarction or cardiovascular death in patients with suspected acute coronary syndrome.

Methods. In this stepped-wedge, cluster-randomised controlled trial across ten secondary or tertiary care hospitals in Scotland, we evaluated the implementation of an hs-cTnI assay in consecutive patients who had been admitted to the hospitals' emergency departments with suspected acute coronary syndrome. Patients were eligible for inclusion if they presented with suspected acute coronary syndrome and had paired cardiac troponin measurements from the standard care and trial assays. During a validation phase of 6–12 months, results from the hs-cTnI assay were concealed from the attending clinician, and a contemporary cardiac troponin I (cTnI) assay was used to guide care. Hospitals were randomly allocated to early (n=5 hospitals) or late (n=5 hospitals) implementation, in which the high-sensitivity assay and sex-specific 99th centile diagnostic threshold was introduced immediately after the 6-month validation phase or was deferred for a further 6 months. Patients reclassified by the high-sensitivity assay were defined as those with an increased hs-cTnI concentration in whom cTnI concentrations were below the diagnostic threshold on the contemporary assay. The primary outcome was subsequent myocardial infarction or death from cardiovascular causes at 1 year after initial presentation. Outcomes were compared in patients reclassified by the high-sensitivity assay before and after its implementation by use of an adjusted generalised linear mixed model. This trial is registered with ClinicalTrials.gov, number NCT01852123.

Findings. Between June 10, 2013, and March 3, 2016, we enrolled 48 282 consecutive patients (61 [SD 17] years, 47% women) of whom 10 360 (21%) patients had cTnI concentrations greater than those of the 99th centile of the normal range of values, who were identified by the contemporary assay or the high-sensitivity assay. The high-sensitivity assay reclassified 1771 (17%) of 10 360 patients with myocardial injury or infarction who were not identified by the contemporary assay. In those reclassified, subsequent myocardial infarction or cardiovascular death within 1 year occurred in 105 (15%) of 720 patients in the validation phase and 131 (12%) of 1051 patients in the implementation phase (adjusted odds ratio for implementation vs validation phase 1·10, 95% CI 0·75 to 1·61; p=0·620).

Interpretation. Use of a high-sensitivity assay prompted reclassification of 1771 (17%) of 10 360 patients with myocardial injury or infarction, but was not associated with a lower subsequent incidence of myocardial infarction or cardiovascular death at 1 year. Our findings question whether the diagnostic threshold for myocardial infarction should be based on the 99th centile derived from a normal reference population.

Funding. The British Heart Foundation.

Full text

From PubMed Central, U.S. National Library of Medicine, as current on Oct 18, 2026. Paragraph numbers are ours, so an answer can point at one.

Introduction

Myocardial infarction is defined by the clinical history, electrocardiogram, and an increase or decrease in cardiac troponin concentration (as evidence of myocardial necrosis). Improvements in assay sensitivity now permit the quantification of very low concentrations of troponin with high precision, which allows the use of lower diagnostic thresholds. The Universal Definition of Myocardial Infarction recommends that an increase in troponin above the 99th centile of a normal reference population should be used as the threshold for diagnosis of myocardial infarction. Furthermore, it recognises that troponin concentrations differ in men and women,, and suggests sex-specific diagnostic thresholds be applied when using high-sensitivity assays.

Evidence before this studyWe searched PubMed for reports published in English between Jan 1, 2010, and July 18, 2018, with the search terms “cardiac troponin”, “myocardial infarction”, “acute coronary syndrome”, and “randomised controlled trials”. Although no randomised controlled trials have evaluated the effects of a high-sensitivity cardiac troponin assay on cardiovascular outcomes, a previous study showed that lowering the diagnostic threshold with a contemporary troponin assay was associated with a reduction in myocardial infarction or death in those reclassified as having had a myocardial infarction. Further, registry studies have shown a reduction in recurrent myocardial infarction but no difference in all-cause mortality following the introduction of a high-sensitivity cardiac troponin assay.Added value of this studyTo our knowledge, this is the first randomised controlled trial to evaluate the effects of implementing a high-sensitivity cardiac troponin I assay in patients with suspected acute coronary syndrome. We show that use of the high-sensitivity assay reclassified one in six patients with myocardial injury, but only a third of these patients had a diagnosis of type 1 myocardial infarction, and the incidence of subsequent myocardial infarction or cardiovascular death at 1 year was unchanged.Implications of all the available evidenceImplementation of a high-sensitivity cardiac troponin assay and use of the 99th centile as the diagnostic threshold identifies more patients with myocardial injury than type 1 myocardial infarction and does not lead to a reduction in subsequent cardiac events. This finding raises the question of whether clinical decisions should be based on a 99th centile threshold derived from a reference population or on an approach that acknowledges the continuum of disease and clinical presentation and optimises diagnostic accuracy. Finally, a high-sensitivity assay can identify low-risk populations, leading to reductions in the overall duration of hospital stay.

Evidence before this study

We searched PubMed for reports published in English between Jan 1, 2010, and July 18, 2018, with the search terms “cardiac troponin”, “myocardial infarction”, “acute coronary syndrome”, and “randomised controlled trials”. Although no randomised controlled trials have evaluated the effects of a high-sensitivity cardiac troponin assay on cardiovascular outcomes, a previous study showed that lowering the diagnostic threshold with a contemporary troponin assay was associated with a reduction in myocardial infarction or death in those reclassified as having had a myocardial infarction. Further, registry studies have shown a reduction in recurrent myocardial infarction but no difference in all-cause mortality following the introduction of a high-sensitivity cardiac troponin assay.

Added value of this study

To our knowledge, this is the first randomised controlled trial to evaluate the effects of implementing a high-sensitivity cardiac troponin I assay in patients with suspected acute coronary syndrome. We show that use of the high-sensitivity assay reclassified one in six patients with myocardial injury, but only a third of these patients had a diagnosis of type 1 myocardial infarction, and the incidence of subsequent myocardial infarction or cardiovascular death at 1 year was unchanged.

Implications of all the available evidence

Implementation of a high-sensitivity cardiac troponin assay and use of the 99th centile as the diagnostic threshold identifies more patients with myocardial injury than type 1 myocardial infarction and does not lead to a reduction in subsequent cardiac events. This finding raises the question of whether clinical decisions should be based on a 99th centile threshold derived from a reference population or on an approach that acknowledges the continuum of disease and clinical presentation and optimises diagnostic accuracy. Finally, a high-sensitivity assay can identify low-risk populations, leading to reductions in the overall duration of hospital stay.

The use of high-sensitivity cardiac troponin assays and lowering the diagnostic threshold to the 99th centile remains a contentious issue in clinical practice; therefore, despite guideline recommendations, few institutions worldwide have adopted high-sensitivity assays., If increased sensitivity does not affect the specificity of testing for the diagnosis of myocardial infarction, then introducing high-sensitivity assays will improve patient outcomes through better targeting of therapies for coronary heart disease. However, if the increase in sensitivity leads to poor specificity, then patients could be misdiagnosed, given inappropriate medications, and potentially have adverse outcomes. We aimed to determine whether the introduction of a high-sensitivity cardiac troponin I (hs-cTnI) assay with a sex-specific 99th centile diagnostic threshold would reduce subsequent myocardial infarction or cardiovascular death within 1 year in patients with suspected acute coronary syndrome who would previously have been classified as not having had a myocardial injury and were reclassified following use of the high-sensitivity assay.

Study design and participants

The High-Sensitivity Troponin in the Evaluation of patients with suspected Acute Coronary Syndrome (High-STEACS) trial is a stepped-wedge, cluster-randomised controlled trial that aimed to prospectively evaluate the implementation of an hs-cTnI assay in consecutive patients with suspected acute coronary syndrome in ten secondary and tertiary care hospitals in Scotland. Sites were eligible if they had the capacity to measure the trial assay and if they returned data to the national hospital admissions database. All patients attending the Emergency Department were screened for suspected acute coronary syndrome by the attending clinician; at the same time, troponin was requested with an electronic form integrated into the clinical care pathway. Patients were eligible for inclusion if they presented with suspected acute coronary syndrome and had paired cardiac troponin measurements from the standard care and trial assays. Patients were excluded if they had been admitted previously during the trial period or were not resident in Scotland.

The study was approved by the Scotland A Research Ethics Committee, the Public Benefit and Privacy Panel for Health and Social Care, and by each National Health Service (NHS) Health Board. The conduct of the trial was periodically reviewed by an independent data monitoring committee. All data were collected prospectively from the electronic patient record, de-identified and linked within secure NHS Safe Havens (figure 1).

Randomisation and masking

In this trial, the hospital site was the unit of randomisation. Cluster randomisation was necessary to avoid the risk of clinical error due to reporting of different troponin assays and thresholds simultaneously. All sites reported cardiac troponin concentration by use of a contemporary troponin assay and an existing diagnostic threshold in a validation phase of at least 6 months. Sites were paired based on expected number of patients presenting with suspected acute coronary syndrome before they were randomly allocated to early or late implementation of the high-sensitivity assay (with sex-specific thresholds) for the diagnosis of myocardial infarction (figure 1; appendix). Allocation was masked from sites before their inclusion in the trial and allocation was masked from individual participants throughout.

Procedures

Cardiac troponin testing was done when patients presented at the hospital and was repeated 6 or 12 hours after the onset of symptoms, at the discretion of the attending physician and in accordance with national and international guidelines., Throughout the trial period, contemporary and high-sensitivity troponin assays were run simultaneously in plasma that had been taken but was surplus to clinical requirements. Attending clinicians were masked to the results of the high-sensitivity assay during the validation phase and the contemporary assay during the implementation phase.

In the validation phase, a contemporary cardiac troponin I (cTnI) assay (Abbott Laboratories; Abbott Park, IL, USA) was used to guide clinical decisions. The inter-assay coefficient of variation was determined at each site and was less than 10% at 40 ng/L (seven sites) and 50 ng/L (three sites). Only cTnI concentrations above these diagnostic thresholds were reported. During the implementation phase, an hs-cTnI assay (ARCHITECTSTAT high-sensitive troponin I assay; Abbott Laboratories) was used to guide clinical decisions. This assay has an interassay coefficient of variation of less than 10% at 4·7 ng/L, and a 99th centile upper reference limit of 34 ng/L in men and 16 ng/L in women. To support implementation, we provided written educational material and presentations at each site and training for clinical and laboratory staff, and we updated the electronic patient record to highlight the change in assay and diagnostic thresholds.

We collected clinical information from a standardised electronic patient record (TrakCare; InterSystems Corporation, Cambridge, MA, USA). All patients with hs-cTnI concentrations above the 99th centile were assessed in accordance with the Universal Definition of Myocardial Infarction, as previously described., Two physicians who were masked to the study phase independently reviewed all clinical information, and discordant diagnoses were resolved by a third reviewer. Type 1 myocardial infarction was defined as myocardial necrosis (any hs-cTnI concentration above the 99th centile with an increase or decrease in hs-cTnI concentration, where serial testing was done) in the context of a presentation with suspected acute coronary syndrome, with symptoms or signs of myocardial ischaemia on an electrocardiogram. Symptoms or signs of myocardial ischaemia due to increased oxygen demand or decreased oxygen supply (for example, tachyarrhythmia, hypotension, or anaemia) secondary to an alternative pathology and myocardial necrosis were defined as type 2 myocardial infarction. Type 4a myocardial infarction was defined in patients with symptoms or signs of myocardial ischaemia following percutaneous coronary intervention, where hs-cTnI concentrations were 5 times greater than the 99th centile, or when concentrations had increased further if they were increased before the procedure. Type 4b myocardial infarction was defined as myocardial ischaemia and myocardial necrosis that was associated with stent thrombosis, documented at angiography. Myocardial injury was defined as hs-cTnI concentrations greater than the 99th centile of normal reference values in the absence of any clinical features of myocardial ischaemia.

The study population was stratified by peak troponin concentration. Patients with hs-cTnI concentrations within the reference range (1–16 ng/L in women, 1–34 ng/L in men) were classified as having no myocardial injury. Patients with myocardial injury identified by the contemporary assay were defined as those with any cTnI concentration greater the diagnostic threshold of this assay. Patients reclassified by the hs-cTnI assay were defined as those with an increased hs-cTnI concentration (>16 ng/L for women, >34 ng/L for men), in whom cTnI concentrations were below the diagnostic threshold on the contemporary assay.

Outcomes

We used regional and national registries to ensure complete follow-up for the trial population,,, (figure 1; appendix). The prespecified primary outcome was subsequent myocardial infarction (type 1 or type 4b) or cardiovascular death within 1 year following the initial presentation to hospital. Primary outcome events were adjudicated by investigators who were masked to troponin concentrations during the index (ie, initial) presentation and study phase. The secondary efficacy outcomes were duration of hospital stay, myocardial infarction (type 1 or type 4b), unplanned coronary revascularisation, all-cause death, death from cardiovascular causes (cardiac and non-cardiac), hospital admission for heart failure, and ischaemic stroke. Secondary safety outcomes were major haemorrhage, unplanned hospital admission, excluding acute coronary syndrome, and non-cardiovascular death.

Statistical analysis

We estimated that 6·4% of patients would be reclassified by the high-sensitivity assay and that the event rate for the primary outcome would be 13% in this group. Based on the planned inclusion of ten sites, power was 74–85% for an absolute risk reduction of 4·4%, if the proportion reclassified was between 6% and 9%, and the intra-cluster correlation coefficient was between 0·05 and 0·10 (appendix). Outcomes were compared in patients who had been reclassified by the hs-cTnI assay before and after its implementation by use of a generalised linear mixed effects model; the effects of the intervention were presented as odds ratios (ORs) with 95% CIs. The model adjusted for site, season, and time of presentation from the start date of the trial. Hospital site was fitted as a random effect, and age, sex, and social deprivation were included as fixed patient-level covariates. In a sensitivity analysis, an additional random effect was included in the primary analysis model to test for site-by-intervention interaction. Outcome event times were summarised descriptively before and after implementation of the high-sensitivity assay by use of Kaplan-Meier survival curves, and differences between phases were tested with a log-rank test. Statistical analysis was done with SAS version 9.4. This trial is registered with ClinicalTrials.gov, number NCT01852123.

Role of the funding source

The funders of the study had no role in study design, data collection, data analysis, data interpretation, or writing of the report. The corresponding author had full access to all the data in the study and had final responsibility for the decision to submit for publication.

Results

Ten of the 23 secondary or tertiary care hospitals in Scotland were eligible and all of these ten hospitals participated (appendix). Between June 10, 2013, and March 3, 2016, 48 282 consecutive patients with suspected acute coronary syndrome (61 [SD 17] years, 47% women) met the trial inclusion criteria (appendix) and were included in the analysis of the primary outcome. The trial concluded on March 3, 2017, after a minimum follow-up period of 1 year. 18 978 (39%) patients were admitted during the validation phase and 29 304 (61%) patients were admitted during the implementation phase. 32 045 (66%) patients were admitted across sites assigned to the early implementation group and 16 237 (34%) patients were admitted across sites assigned to the late implementation group.

Baseline characteristics of the study population are summarised in table 1, stratified by phase and analysis population. The study population was stratified by peak troponin concentration. During the initial presentation to hospital, we identified 10 360 (21%) of these 48 282 patients with hs-cTnI concentrations greater than the 99th centile of normal reference values. Of the 10 360 patients with increased hs-cTnI concentrations, 1771 (17%) patients were reclassified by the high-sensitivity assay and 8589 (83%) patients were identified by the contemporary assay (table 1). Patients reclassified were older (75 [SD 14] years in the reclassified group vs 70 [15] years in those identified by the contemporary assay) and twice as likely to be women (83% vs 41%) than those identified by the contemporary assay. Compared with patients identified by the contemporary assay, those reclassified were as likely to present with chest pain (67% in those reclassified vs 71% in those identified by the cTn I assay) and have a history of ischaemic heart disease (36% vs 33%), but were less likely to show myocardial ischaemia on the electrocardiograph (14% vs 36%). Clinical characteristics (such as presenting symptoms and comorbidities) were similar in each analysis population across both phases (appendix).

Patients were followed up for 1 year for all primary and secondary outcome measures. Within 1 year, 2586 (5%) of 48 282 patients with suspected acute coronary syndrome had a subsequent myocardial infarction or death from cardiovascular causes (table 2). The primary outcome occurred in 1106 (6%) of 18 978 patients who presented during the validation phase and in 1480 (5%) of 29 304 patients who presented during the implementation phase (adjusted OR for implementation vs validation phase 1·05, 95% CI 0·92–1·19; p=0·48). Patients with myocardial injury were more likely than those without to have a subsequent myocardial infarction or death from cardiovascular causes within 1 year (figure 2). In patients who were reclassified by the high-sensitivity assay, the primary outcome occurred in 105 (15%) of 720 patients during the validation phase and 131 (12%) of 1051 patients in the implementation phase (1·10, 0·75–1·61; p=0·620; figure 3). In reclassified patients, there were no differences in any of the secondary efficacy and safety outcome measures between phases (table 2; figure 3).

The index diagnosis was adjudicated in all patients with hs-cTnI concentrations greater than the 99th centile. Where a consensus was reached by the adjudication panel in 9115 (88%) patients, the diagnosis was type 1 myocardial infarction in 5028 (55%) patients, type 2 myocardial infarction in 1260 (14%) patients, and myocardial injury in 2810 (31%) patients. Compared with patients identified by the contemporary assay, those reclassified by the high-sensitivity assay were less likely to have type 1 myocardial infarction (515 [33%] patients who had been reclassified vs 4513 [60%] patients who had been identified by the contemporary assay), and more likely to be classified as having myocardial injury (796 [51%] patients vs 2014 [27%] patients).

Management during the index presentation was compared. Patients reclassified by the high-sensitivity assay were more likely to undergo coronary angiography in the implementation phase compared with the validation phase (11% in the implementation phase vs 4% in the validation phase), but percutaneous coronary intervention (5% vs 3%) did not differ (table 3). Similarly, there were more new prescriptions for additional anti-platelet therapy (18% vs 9%) and other secondary prevention agents during the implementation phase than the validation phase. The duration of hospital stay was longer in the implementation phase than the validation phase in reclassified patients (median 51 h, IQR 20–134 in the implementation phase; vs 21 h, 4–101 in the validation phase), but was shorter in patients without myocardial injury (4 h, 3–20; vs 7 h, 3–24) and in the study population overall (8 h, 3–40; vs 11 h, 4–38; table 3).

Discussion

We evaluated whether the use of a high-sensitivity cardiac troponin assay was beneficial or harmful in 48 282 consecutive patients with suspected acute coronary syndrome. Introduction of the high-sensitivity assay prompted reclassification of 1771 (17%) patients with myocardial injury; however, only a third of these patients had a diagnosis of type 1 myocardial infarction and the incidence of subsequent myocardial infarction or death from cardiovascular causes within 1 year was not changed by introduction of this high-sensitivity assay.

There are several strengths of our trial design. First, we enrolled consecutive patients in whom the attending clinician suspected acute coronary syndrome by embedding our screening tool into the electronic health-care system. Because the intervention was implemented at hospital level, consent was not sought from individual patients. This study design also avoided selection bias and ensured that, unlike in most cardiovascular trials, our study population was representative, comprising low-risk and high-risk individuals, an equal proportion of men and women, patients who presented out-of-hours, and those who were unwell and unlikely to survive. Second, throughout the trial, contemporary and high-sensitivity troponin assays were run simultaneously in plasma that was surplus to requirement, to accurately identify all patients reclassified by high-sensitivity testing during both phases of the trial. Third, we used established regional and national registries, to track investigations, treatments, and outcomes in all patients through linkage of electronic health-care records ensuring 100% follow-up in those patients who remained resident in Scotland. Finally, these linked datasets were used to assess all index and primary outcome events in accordance with the Universal Definition of Myocardial Infarction.

We previously showed that lowering the diagnostic threshold with a contemporary troponin assay was associated with a reduction in myocardial infarction or death in those reclassified as having myocardial infarction. Despite these improvements, several observational studies,, that evaluated high-sensitivity assays have suggested that myocardial infarction is underdiagnosed with contemporary assays and that misdiagnosis is associated with excess mortality. In this context, we expected that the introduction of a high-sensitivity assay would improve outcomes. However, we observed no difference in the primary or secondary efficacy outcomes within 1 year in patients reclassified with the high-sensitivity assay. This finding was despite the assay identifying a group with similar cardiovascular risk factors as those with more extensive myocardial injury, and despite 236 (13%) of 1771 patients having a subsequent myocardial infarction or cardiovascular death within 1 year.

Several observations could explain our findings. First, only a third of patients who were reclassified by the high-sensitivity assay actually had a diagnosis of type 1 myocardial infarction and would therefore benefit from evidence-based therapies. Second, although patients with myocardial injury or type 2 myocardial infarction are known to have poor outcomes,,, this population is very heterogeneous, and no evidence from randomised trials yet exists to guide treatment in these patients. Third, although new prescriptions for anti-platelet, statin, and beta-blocker therapies doubled and the frequency of coronary angiography tripled in the implementation phase, overall only 1 in 10 patients received an additional secondary preventive drug or underwent angiography. However, many patients reclassified by the high-sensitivity assay were already known to have ischaemic heart disease and were receiving secondary prevention at the time of presentation, which might have attenuated the potential to improve outcomes. Finally, most patients reclassified by the high-sensitivity assay were women, because the sex-specific 99th centile is lower in women than men. Many studies, have reported that women are less likely to receive investigations and treatments for coronary heart disease than men, and this could have further attenuated any benefit of implementing the high-sensitivity assay.

Although the duration of stay doubled in those reclassified by the high-sensitivity assay, it was reduced by a third across the trial population. This reduction was because most patients did not have myocardial injury or infarction, and their duration of hospital stay halved. Importantly, implementation might have improved the treating clinician's confidence that myocardial infarction had been ruled out, resulting in an earlier discharge; our findings of reduced hospital stay duration are consistent with a previous study. Emerging evidence suggests that very low hs-cTnI concentrations at presentation can identify half of all patients as low risk.,, Similar observations have been reported for cardiac troponin T,, and risk stratification thresholds below the 99th centile have been incorporated into early rule-out pathways.,,,, The 2016 European Society of Cardiology guidelines recommend the use of pathways that incorporate thresholds below the 99th centile and small changes in cardiac troponin to improve both the rule-in and rule-out of myocardial infarction. Together, these approaches have the potential to improve the efficiency of health-care systems, but prospective randomised controlled trials are ongoing to determine the effectiveness and safety of these pathways and their impact on patient care (such as ClinicalTrials.gov NCT03005158 and Australian New Zealand Clinical Trials Registry ACTRN12615001379505).

To our knowledge, our findings represent the first evidence from a randomised controlled trial that evaluates the recommendations of the Universal Definition of Myocardial Infarction. Despite consistently implementing these guidelines across all sites, use of the hs-cTn I assay did not improve outcomes for patients. In contrast to earlier studies, in which improvements in assay performance were associated with benefits in reducing the diagnostic threshold from 200 ng/L to 50 ng/L, further reductions identified a heterogeneous group of patients. The recommendation that the 99th centile from a healthy reference population be used to diagnose myocardial infarction is based on expert consensus and observational studies rather than evidence from randomised controlled trials. Registry studies,, suggest that the introduction of a high-sensitivity cardiac troponin T assay was associated with better risk stratification of patients in the Emergency Department and more percutaneous coronary intervention with lower rates of recurrent myocardial infarction, but these studies showed no difference in all-cause mortality. By contrast, we showed that implementation of a high-sensitivity assay did not improve clinical outcomes in our randomised controlled trial despite accurately identifying the group of patients most likely to benefit. This finding raises the question of what is the optimal approach to diagnose myocardial infarction. Should clinical decisions be based on a statistical threshold derived from a reference population, or an approach that acknowledges the continuum of disease and optimises diagnostic accuracy?

There are some study limitations. This was a pragmatic trial, and therefore we had to accept some flexibility in the implementation phase to accommodate shared out-of-hours laboratory services, shared electronic patient records, and site closures (appendix). The proportion of patients reclassified with the high-sensitivity assay was smaller than anticipated from our pilot study but, given the consistency of our findings across a range of endpoints, it is unlikely a larger trial would have yielded a different result. Hospitals that use lower contemporary assay thresholds would reclassify fewer patients when implementing a high-sensitivity assay, but the effect on subsequent myocardial infarction or death from cardiovascular causes would probably be similar. A previous study has suggested that higher diagnostic thresholds should be applied in patients with renal impairment, and we did not evaluate this approach in our trial. However, renal function was similar in patients with myocardial injury, whether reclassified by the high-sensitivity assay or identified by the contemporary assay, suggesting that the prevalence of this comorbidity is not the primary explanation for our findings. Finally, further research is required to understand how the changing criteria for the classification of patients with myocardial injury and infarction will affect patient management and clinical outcomes.

In conclusion, we have shown that implementation of a high-sensitivity cardiac troponin I assay prompted reclassification of 1771 (17%) of 10 360 patients with myocardial injury; however, only a third of these patients had a diagnosis of type 1 myocardial infarction, and the incidence of subsequent myocardial infarction or death from cardiovascular causes within 1 year was not affected by use of this assay.

References 39

  1. 1.

    Thygesen K, Alpert JS, Jaffe AS. Third universal definition of myocardial infarction. Circulation. 2012;126:2020-2035.

    Not in our library10.1161/cir.0b013e31826e1058

  2. 2.

    Apple FS, Collinson PO. Analytical characteristics of high–sensitivity cardiac troponin assays. Clin Chem. 2012;58:54-61.

    Not in our library10.1373/clinchem.2011.165795

  3. 3.
  4. 4.

    Kimenai DM, Janssen EBNJ, Eggers KM. Sex-specific versus overall clinical decision limits for cardiac troponin I and T for the diagnosis of acute myocardial infarction: a systematic review. Clin Chem. 2018;64:1034-1043.

    Not in our library10.1373/clinchem.2018.286781

  5. 5.

    Mills NL, Lee KK, McAllister DA. Implications of lowering threshold of plasma troponin concentration in diagnosis of myocardial infarction: cohort study. BMJ. 2012;344:e1533.

    Not in our library10.1136/bmj.e1533

  6. 6.

    Bagai A, Alexander KP, Berger JS. Use of troponin assay 99th percentile as the decision level for myocardial infarction diagnosis. Am Heart J. 2017;190:135-139.

    Not in our library10.1016/j.ahj.2017.04.016

  7. 7.

    Anand A, Shah ASV, Beshiri A, Jaffe AS, Mills NL. Global adoption of high-sensitivity cardiac troponins and the universal definition of myocardial infarction. bioRxiv. 2018.

    Not in our library10.1101/371138

  8. 8.

    NHS National Services Scotland Information Services Division, National Statistics. Scottish heart disease statistics. A national statistics publication for Scotland. Jan 30, 2018.

    Not in our library

  9. 9.

    Scottish Intercollegiate Guidelines Network. Acute coronary syndromes. February, 2013.

    Not in our library

  10. 10.

    Hamm CW, Bassand JP, Agewall S. ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: the task force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC). Eur Heart J. 2011;32:2999-3054.

    Not in our library10.1093/eurheartj/ehr236

  11. 11.

    Mills NL, Churchhouse AM, Lee KK. Implementation of a sensitive troponin I assay and risk of recurrent myocardial infarction and death in patients with suspected acute coronary syndrome. JAMA. 2011;305:1210-1216.

    Not in our library10.1001/jama.2011.338

  12. 12.

    Shah AS, Anand A, Sandoval Y. High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome. Lancet. 2015;386:2481-2488.

    Not in our library10.1016/s0140-6736(15)00391-8

  13. 13.

    Shah ASV, Sandoval Y, Noaman A. Patient selection for high sensitivity cardiac troponin testing and diagnosis of myocardial infarction: prospective cohort study. BMJ. 2017;359:j4788.

    Not in our library10.1136/bmj.j4788

  14. 14.

    Miller-Hodges E, Anand A, Shah ASV. High-sensitivity cardiac troponin and the risk stratification of patients with renal impairment presenting with suspected acute coronary syndrome. Circulation. 2018;137:425-435.

    Not in our library10.1161/circulationaha.117.030320

  15. 15.

    SCOT-HEART investigators. CT coronary angiography in patients with suspected angina due to coronary heart disease (SCOT-HEART): an open-label, parallel-group, multicentre trial. Lancet. 2015;385:2383-2391.

    Not in our library10.1016/s0140-6736(15)60291-4

  16. 16.

    Ford I, Norrie J. Pragmatic trials. N Engl J Med. 2016;375:454-463.

    Not in our library10.1056/nejmra1510059

  17. 17.

    Keller T, Zeller T, Peetz D. Sensitive troponin I assay in early diagnosis of acute myocardial infarction. N Engl J Med. 2009;361:868-877.

    Not in our library10.1056/nejmoa0903515

  18. 18.

    Reichlin T, Hochholzer W, Bassetti S. Early diagnosis of myocardial infarction with sensitive cardiac troponin assays. N Engl J Med. 2009;361:858-867.

    Not in our library10.1056/nejmoa0900428

  19. 19.

    Christ M, Popp S, Pohlmann H. Implementation of high sensitivity cardiac troponin T measurement in the emergency department. Am J Med. 2010;123:1134-1142.

    Not in our library10.1016/j.amjmed.2010.07.015

  20. 20.

    Pope JH, Aufderheide TP, Ruthazer R. Missed diagnoses of acute cardiac ischemia in the emergency department. N Engl J Med. 2000;342:1163-1170.

    Not in our library10.1056/nejm200004203421603

  21. 21.

    Shah AS, McAllister DA, Mills R. Sensitive troponin assay and the classification of myocardial infarction. Am J Med. 2015;128:493-501.

    Not in our library10.1016/j.amjmed.2014.10.056

  22. 22.
  23. 23.

    Sandoval Y, Smith SW, Sexter A. Type 1 and 2 myocardial infarction and myocardial injury: clinical transition to high-sensitivity cardiac troponin I. Am J Med. 2017;130:1431-1439.

    Not in our library10.1016/j.amjmed.2017.05.049

  24. 24.

    Shah ASV, Ferry AV, Mills NL. Cardiac biomarkers and the diagnosis of myocardial infarction in women. Curr Cardiol Rep. 2017;19:40.

    Not in our library10.1007/s11886-017-0839-9

  25. 25.

    Twerenbold R, Jaeger C, Rubini Gimenez M. Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction. Eur Heart J. 2016;37:3324-3332.

    Not in our library10.1093/eurheartj/ehw232

  26. 26.

    Chapman AR, Lee KK, McAllister DA. Association of high-sensitivity cardiac troponin I concentration with cardiac outcomes in patients with suspected acute coronary syndrome. JAMA. 2017;318:1913-1924.

    Not in our library10.1001/jama.2017.17488

  27. 27.

    Neumann JT, Sörensen NA, Ojeda F. Immediate rule-out of acute myocardial infarction using electrocardiogram and baseline high-sensitivity troponin I. Clin Chem. 2017;63:394-402.

    Not in our library10.1373/clinchem.2016.262659

  28. 28.

    Body R, Carley S, McDowell G. Rapid exclusion of acute myocardial infarction in patients with undetectable troponin using a high-sensitivity assay. J Am Coll Cardiol. 2011;58:1332-1339.

    Not in our library10.1016/j.jacc.2011.06.026

  29. 29.

    Pickering JW, Than MP, Cullen L. Rapid rule-out of acute myocardial infarction with a single high-sensitivity cardiac troponin T measurement below the limit of detection: a collaborative meta-analysis. Ann Intern Med. 2017;166:715-724.

    Not in our library10.7326/m16-2562

  30. 30.

    Reichlin T, Schindler C, Drexler B. One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T. Arch Intern Med. 2012;172:1211-1218.

    Not in our library10.1001/archinternmed.2012.3698

  31. 31.

    Rubini Gimenez M, Twerenbold R, Jaeger C. One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I. Am J Med. 2015;128:861-870.

    Not in our library10.1016/j.amjmed.2015.01.046

  32. 32.

    Boeddinghaus J, Reichlin T, Cullen L. Two-hour algorithm for triage toward rule-out and rule-in of acute myocardial infarction by use of high-sensitivity cardiac troponin I. Clin Chem. 2016;62:494-504.

    Not in our library10.1373/clinchem.2015.249508

  33. 33.

    Neumann JT, Sörensen NA, Schwemer T. Diagnosis of myocardial infarction using a high-sensitivity troponin I 1-hour algorithm. JAMA Cardiol. 2016;1:397-404.

    Not in our library10.1001/jamacardio.2016.0695

  34. 34.

    Chapman AR, Anand A, Boeddinghaus J. Comparison of the efficacy and safety of early rule-out pathways for acute myocardial infarction. Circulation. 2017;135:586-596.

    Not in our library10.1161/circulationaha.116.025021

  35. 35.

    Roffi M, Patrono C, Collet JP. 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: task force for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC). Eur Heart J. 2016;37:267-315.

    Not in our library10.1093/eurheartj/ehv320

  36. 36.

    Eggers KM, Lindahl B, Melki D, Jernberg T. Consequences of implementing a cardiac troponin assay with improved sensitivity at Swedish coronary care units: an analysis from the SWEDEHEART registry. Eur Heart J. 2016;37:2417-2424.

    Not in our library10.1093/eurheartj/ehw029

  37. 37.

    Nejatian A, Omstedt Å, Höijer J. Outcomes in patients with chest pain discharged after evaluation using a high-sensitivity troponin T assay. J Am Coll Cardiol. 2017;69:2622-2630.

    Not in our library10.1016/j.jacc.2017.03.586

  38. 38.

    Odqvist M, Andersson PO, Tygesen H, Eggers KM, Holzmann MJ. High-sensitivity troponins and outcomes after myocardial infarction. J Am Coll Cardiol. 2018;71:2616-2624.

    Not in our library10.1016/j.jacc.2018.03.515

  39. 39.

    Twerenbold R, Wildi K, Jaeger C. Optimal cutoff levels of more sensitive cardiac troponin assays for the early diagnosis of myocardial infarction in patients with renal dysfunction. Circulation. 2015;131:2041-2050.

    Not in our library10.1161/circulationaha.114.014245

Cited by papers we hold 4

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.