Skip to content
naulon
Not checkedNot checked for notices yet.

Retrograde femoral nails for emergency stabilization in multiply injured patients with haemodynamic instability

Sultan Al Maskari, Rahil Muzaffar, Ahmed Yaseen

Trauma Case Reports · 2020

doi:10.1016/j.tcr.2020.100350 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Introduction: The purpose of this study is to retrospectively evaluate the immediate effect of retrograde intramedullary femoral nail (RIMFN) fixation technique on patient's hemodynamic status as documented by vital signs (blood pressure and pulse) intraoperatively in all patients with femoral shaft fractures with multiple injuries and hemodynamic instability who were treated with RIMFN at our institution on emergency basis as part of damage control orthopaedics. Patients and methods: A retrospective review of intra operative vital signs obtained from patient records was completed at a Level 1 trauma center in a university hospital.In all, 11 multiply injured patients with (14) femur fractures with hemodynamic instability were identified. Of those, 3 had bilateral femur fractures. Closed reduction and retrograde femoral nailing without proximal locking was performed to achieve immediate skeletal and haemodynamic stability. Pulse rate and BP measurements were noted for all patients starting from the time patient would enter the operating room till the patient was shifted back to the recovery ward. Results: The average cohort age was 28 years (20–36 years). The average Injury Severity Score was 28 (16–50). Statistically significant improvement in pulse rate and blood pressure was noted following femoral fracture fixation with intramedullary nail. No cases of infection or symptomatic fat or pulmonary embolism were encountered. One patient required exchange nailing for non-union and one femur underwent later lengthening. Conclusions: Retrograde Intramedullary femoral nail can be an effective alternative to external fixator as damage control device and is associated with immediate improvement in vital signs (pulse and blood pressure) intra operatively.

Abstract licence: CC BY-NC

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.