Electrochemical evaluation of Cd2+ and Hg2+ ions in water using ZnO/Cu2ONPs/PANI modified SPCE electrode

Enyioma C. Okpara, Omolola E. Fayemi, El-Sayed M. Sherif and 3 more

Sensing and Bio-Sensing Research · 2022

doi:10.1016/j.sbsr.2022.100476 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Metal oxides NPs synthesized using orange peels extract (OE) and lemon peels extract (LE) and polyaniline (PANI) were used to modify the surface of screen printed carbon electrode (SPCE). The electrochemical responses of the various working electrode in potassium hexacyanoferrate (III) probe, and HCl electrolyte were evaluated using cyclic voltammetry. Integrating bimetal oxides NPs Cu2O/ZnO NPs with PANI on SPCE surface increased the electron transport properties of the sensors. The analytical performance of the SPCE treated with OE/Cu2O/ZnONPs/PANI composite, (OE/ZnO/Cu2ONPs/PANI/SPCE) and their counterpart LE/Cu2O/ZnONPs/PANI composite (LE/ZnO/Cu2ONPs/PANI/SPCE), on Cd2+, and Hg2+ ions in 0.1 M HCl electrolyte, was investigated using square voltammetry (SWV). The limits of detection at concentration range of 2.2–12.0 μM, and 0.17–1.5 μM for Cd2+ were 3.04 ppb, and 1.08 ppb, while for Hg2+ at concentration range of 2.95–11.8 μM, and 0.12–1.2 μM, the values were 5.08 ppb, and 2.72 ppb at LE/Cu2O/ZnONPs/PANI/SPC, and OE/Cu2O/ZnONPs/PANI/SPC modified electrodes respectively. The sensitivities of 108 μA/μM, and 27 μA/μM towards Hg2+, and Cd2+ were realized at OE/Cu2O/ZnONPs/PANI/SPCE, despite the narrow linear range. Relative standard deviations (RSD) at 6.55 μM concentrations for Cd2+ were 2.54%, and 6.50% for LE/Cu2O/ZnONPs/PANI/SPCE, and OE/Cu2O/ZnONPs/PANI/SPCE respectively, while the RSDs for Hg2+ at 2.94 μM concentration were 2.92%, and 4.44% using LE/Cu2O/ZnONPs/PANI/SPCE, and OE/Cu2O/ZnONPs/PANI/SPCE respectively. At OE/Cu2O/ZnONPs/PANI/SPCE, there was no significant drop in the anodic peak current for both target trace metals, in the presence of interferences, like Co2+, Mg2+, Fe2+, Ni2+, Zn2+ and Cu2+, except for 11.39% drop of the stripping peak current of Cd2+ in the presence of Zn2+. Hence, the economy of nanotechnology and sensing could profit from the recycling of biomass wastes, which are frequently poorly managed.

Abstract licence: CC BY-NC

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.