Skip to content
naulon
Not checkedNot checked for notices yet.

QUALITY OF LIFE AND NUTRITIONAL STATUS ASSESSED BY MULTIFREQUENCY BIOIMPEDANCE SPECTROSCOPY IN HEMODIALYSIS VERSUS PERITONEAL DIALYSIS PATIENTS

Somchai Yongsiri, Pakapan Dinchuthai, Suriya Prongnamjai and 4 more

Kidney Research and Clinical Practice · 2012

doi:10.1016/j.krcp.2012.04.602 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Bioimpedance spectroscopy with body composition model is a validated method to assess hydration and nutritional status in dialysis patients. The aim of this study is to compare quality of life, nutrition status and hydration status between hemodialysis and peritoneal dialysis patients. There were 26 PD and 32 HD patients included in this study. Multifrequency bioimpedance spectroscopy were measured by BCM-body composition monitor (Fresenius medical care) device, the device provided body composition parameters including Lean Tissue index (LTI) Fat tissue index (FTI) and quantified over hydration status (OH). Quality of life was measured by WHO-QOL-BREF questionnaire. Scheffe’s test was used for comparison and p<0.05 was considered as statistically significant. All of the PD patients had weekly Kt/V>1.7 and all of the HD patients had weekly Kt/V>3.6. There were no differences in Charlson’s comobidity index, food intake, protein intake, BMI, blood pressure and quality of life between groups. LTI and FTI between PD (12.26+3.65, 10.79+5.84) and HD (11.48+3.48, 10.52+4.67) patients were not statistically different. PD patients had more over hydration when compare to HD patients (16.18+11.24 vs. 2.36+11.07%OH/ECW p<0.0001) and ECW to ICW ratio was higher in PD patients (1.02+0.21 vs. 0.89+0.18 p=0.035). Parameters PD HD p-value WHO-QOL 89.23+14.19 88.85+12.35 0.98 LTI (kg/m2) 12.26+3.65 11.48+3.48 0.70 FTI (kg/m2) 10.79+5.84 10.52+4.67 0.96 OH/ECW (%) 16.18+11.24 2.36+11.07 <0.0001 ECW/ICW 1.02+0.21 0.89+0.18 0.035 In conclusion, quality of life and Nutritional status were not difference between PD and HD patients. PD patients had more over hydration and ECW to ICW ratio as assessed by bioimpedance spectroscopy.

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.