A novel case of a pseudoaneurysm due to thermal injury from a cement hip spacer
Madeleine de Boer, MBBS, Timothy Shiraev, BSc (Hons), MBBS (Hons), FRACS, Steven Dubenec, BSc (Med), MBBS, FRACS
Journal of Vascular Surgery Cases and Innovative Techniques · 2021
doi:10.1016/j.jvscit.2021.02.007 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Vascular injuries sustained during total hip replacements are associated with life- and limb-threatening complications. In the present report, we have described a novel vascular injury of an external iliac artery pseudoaneurysm repaired with an interposition vein graft. The vascular injury had been caused by heat from the curing process of a nearby cement hip spacer. During the curing process of bone cement, in vivo temperatures of ≤70°C can be reached, with such temperatures creating the potential for vascular injury. This case highlights the importance of limiting the exposure of surrounding neurovascular structures to bone cement to reduce the risk of thermal injury.
Abstract licence: CC BY-NC-ND