Skip to content
naulon

No retraction, correction or concern found when last checked on Oct 25, 2026.

Extracellular volume quantification by dynamic equilibrium cardiac computed tomography in cardiac amyloidosis

Thomas A. Treibel, Steve Bandula, Marianna Fontana and 8 more

Journal of Cardiovascular Computed Tomography · 2015 · CC BY

doi:10.1016/j.jcct.2015.07.001

Abstract

Background. Cardiac involvement determines outcome in patients with systemic amyloidosis. There is major unmet need for quantification of cardiac amyloid burden, which is currently only met in part through semi-quantitative bone scintigraphy or Cardiovascular Magnetic Resonance (CMR), which measures ECVCMR. Other accessible tests are needed.

Objectives. To develop cardiac computed tomography to diagnose and quantify cardiac amyloidosis by measuring the myocardial Extracellular Volume, ECVCT.

Methods. Twenty-six patients (21 male, 64 ± 14 years) with a biopsy-proven systemic amyloidosis (ATTR n = 18; AL n = 8) were compared with twenty-seven patients (19 male, 68 ± 8 years) with severe aortic stenosis (AS). All patients had undergone echocardiography, bone scintigraphy, NT-pro-BNP measurement and EQ-CMR. Dynamic Equilibrium CT (DynEQ-CT) was performed using a prospectively gated cardiac scan prior to and after (5 and 15 minutes) a standard Iodixanol (1 ml/kg) bolus to measure ECVCT. ECVCT was compared to the reference ECVCMR and conventional amyloid measures: bone scintigraphy and clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area).

Results. ECVCT and ECVCMR results were well correlated (r2 = 0.85 vs r2 = 0.74 for 5 and 15 minutes post bolus respectively). ECVCT was higher in amyloidosis than AS (0.54 ± 0.11 vs 0.28 ± 0.04, p<0.001) with no overlap. ECVCT tracked clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area), and bone scintigraphy amyloid burden (p<0.001).

Conclusion. Dynamic Equilibrium CT, a 5 minute contrast-enhanced gated cardiac CT, has potential for non-invasive diagnosis and quantification of cardiac amyloidosis.

Full text

From PubMed Central, U.S. National Library of Medicine, as current on Oct 25, 2026. Paragraph numbers are ours, so an answer can point at one.

Introduction

Systemic amyloidosis is a multisystem disease caused by the deposition of misfolded fibrillar protein in tissues and organs causing expansion of the extracellular space and impairment of function., Cardiac involvement is a leading cause of morbidity and mortality, with two types commonly infiltrating the ventricular myocardium: immunoglobulin light-chain (AL) type and transthyretin (ATTR) type.,, With current or pending new treatment options for both,, improved diagnosis of cardiac involvement is becoming increasingly important. However current clinical algorithms do not allow quantification of cardiac burden.,, Invasive cardiac biopsy is prone to sampling error and unsuitable for monitoring therapy. Although certain types of bone scintigraphy, and conventional cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE) can detect cardiac amyloid, neither is truly quantitative and both have limitations – for example, bone tracers are insensitive in AL amyloidosis and SAP scintigraphy does not image cardiac amyloid.

Extracellular volume fraction (ECV) quantified by Equilibrium Contrast CMR (EQ-CMR) tracks amyloid burden. Equilibrium Computed Tomography can also quantify the ECV from pre and post contrast measurements of attenuation, and shows good correlation with ECV measured by EQ-CMR as well as histological measures of myocardial fibrosis.,, CT has advantages over CMR: ubiquitously available equipment, higher spatial resolution and a simple linear relationship between attenuation (Hounsfield units) and iodine concentration as opposed to the nonlinear effect on relaxivity of hydrogen following administration of gadolinium.

This study was designed to simplify the progenitor equilibrium methods by using a bolus-only, dynamic equilibrium approach (DynEQ-CT) and apply it to an important clinical problem: the non-invasive diagnosis and quantification of cardiac amyloid burden. Our objectives were three-fold: firstly, to evaluate optimal post bolus contrast timing for DynEQ-CT; secondly, to assess the ability to quantify myocardial amyloid against conventional semi-quantitative methods (bone scintingraphy) and clinical markers of cardiac dysfunction; and thirdly, to compare ECVCT against ECVCMR.

Material and methods

All research was carried out at University College London Hospital and the Royal Free NHS Trusts, London, UK, between January 2013 and December 2013. The study was approved by the ethical committee of U.K. National Research Ethics Service (REC reference 09/H0716/75) and conformed to the principles of the Helsinki Declaration. All subjects gave written informed consent to participate in the study. Exclusion criteria were uncontrolled arrhythmia, impaired renal function (estimated glomerular filtration rate <60 mL/min), or contraindications to MR imaging (e.g. implanted devices – exclusion from CMR only). A total of 53 patients were recruited: 26 with systemic amyloidosis (ATTR and AL) and 27 comparator controls with aortic stenosis. All patients underwent 12-lead ECG, DynEQ-CT, EQ-CMR, echocardiography for diastolic function assessment according to European Society of Echocardiography criteria, assays of NT-proBNP and 6-minute walk test where health and patient choice permitted (e.g. arthritis, postural hypotension, neuropathy). Troponin T was measured in amyloid patients only. The ATTR group also underwent bone scintigraphy using 3,3-diphosphono-1,2-propanodicarboxylicacid (DPD).

Amyloid patients

26 patients with systemic amyloidosis were recruited. Eighteen patients had ATTR amyloidosis (16 male, age 68 ± 8 years), and eight patients (5 male, age 56 ± 12 years) had systemic AL amyloidosis. For ATTR, cardiac amyloidosis was defined by presence of ATTR amyloid in a myocardial biopsy (Congo red and immunohistochemical staining) or positive DPD scintigraphy; 6 TTR patients had positive myocardial biopsies. Definite cardiac involvement by DPD was defined as DPD grade 2 or 3, and possible cardiac involvement as grade 1 (i.e. minimal cardiac DPD uptake) in the absence of LVH; in practice, none of these patients had LVH. All TTR patients also underwent sequencing of exons 2, 3, and 4 of the TTR gene: 14 had senile systemic amyloid (SSA) and four TTR patients were familial (V122I [n = 1], V30M [n = 1], E54G [n = 2]). For AL, systemic AL amyloidosis was proven with biopsies from non-cardiac tissues. Cardiac categorization was based on international consensus criteria but with an additional “possible involvement” category, as previously described. Overall, 21 patients were categorized as having definite cardiac amyloidosis (14 ATTR; 7 AL) and 5 patients (4 ATTR; 1 AL) as having possible cardiac involvement.

Comparator group

Twenty-seven age- and sex-matched patients with severe aortic stenosis (19 male, age 68 ± 8 years) underwent DynEQ-CT and CMR (n = 22 with 5 exclusions due to claustrophobia or pacemaker). AS was chosen as a comparator for having LV remodeling and hypertrophy, and allowing for cardiac amyloid to be excluded histologically on myocardial biopsy (Congo red staining) taken during aortic valve surgery as part of a separate study.

DynEQ-CT Protocol

The DynEQ-CT protocol consisted of three steps (Fig. 1 for flow chart): first, a CT scan to obtain baseline pre-contrast blood and myocardial attenuation in Hounsfield units (HU); second, contrast administration and delay so the contrast distributes into a blood:myocardial dynamic equilibration; third, a repeat scan to re-measure blood and myocardial attenuation. The ratio of the change in blood and myocardial attenuation (ΔHU) represents the contrast agent partition coefficient. If the blood volume of distribution is substituted in (1 minus venous hematocrit; obtained prior to imaging), the myocardial extracellular volume, ECVCT, is obtained, reflecting the myocardial interstitium: ECVCT = (1−Hematocrit) × (ΔHUtissue/ΔHUblood).

CT examinations were performed on a 64–detector row CT scanner (Somatom Sensation 64; Siemens Medical Solutions, Erlangen, Germany). A topogram was used to plan CT volumes from the level of the aortic valve to the inferior aspect of the heart, typically a 10 cm slab. Cardiac scans (tube voltage, 120 kV; tube current–time product, 160 mAs; section collimation, 64 detector rows, 1.2-mm section thickness; gantry rotation time, 330 msec) were acquired with prospective gating (65%–75% of R-R interval), and reconstructed into 3-mm-thick axial sections with a B20f kernel.

To establish the best timing, post contrast imaging was performed at both 5- and 15-minutes following a bolus of Iodixanol (652 mg/mL) at a standard dose of 1 mL/kg and injection rate of 3 ml/sec without a saline chaser. An additional single 3 mm slice acquisition at 1-minute (other parameters as previously described) was introduced in the amyloid cohort to aid blood:myocardial boundary detection for segmentation of the myocardium during analysis.

CT image analysis was performed using a free and open-source Digital Imaging and Communications in Medicine viewer (OsiriX v4.1.2; Pixmeo, Bernex, Switzerland) independently by two experienced readers blinded to all other study data; this was repeated by the second reader to establish inter- and intra-observer agreement. Regions of interest (ROIs) were drawn in the contrast-enhanced 1-minute acquisition in axial sections and propagated to the pre-contrast, 5-minute and 15-minute acquisitions. For myocardium, polygonal ROIs were drawn in an axial slice containing the greatest area of myocardial septum; for the blood pool, circular ROIs were drawn in the LV blood pool away from papillary muscles and the myocardial septum to avoid the endocardial edge and therefore partial voluming (Fig. 2). Myocardial and blood attenuation values were used to calculate the ECV fraction as described.

Signal-to-noise ratios (SNR) were measured in five myocardial ROIs per time point from the ratio of the average HU attenuation value to the standard deviation of the HU attenuation. Radiation exposure was quantified using the dose-length product multiplied by a chest conversion coefficient (κ = 0.014 mSv/mGy cm).

EQ-CMR protocol

EQ-CMR was performed using a 1.5-T scanner (Avanto; Siemens Medical Imaging, Erlangen, Germany) either after or at least 24 hours prior to the CT to avoid residual gadolinium causing an increase in measured attenuation. In addition to the standard CMR protocol (Fig. 1 for flow chart), T1 mapping for ECVCMR quantification was performed using ShMOLLI (Shortened Modified Look-Locker Inversion recovery), providing a single-section T1 map in one breath-hold. For CMR image analysis, a large ROI was drawn manually by a reader blinded to the clinical data on each image to define the septum and blood pool; source data and error maps were used for quality control (Fig. 2).

99mTc-DPD bone scintigraphy

For the ATTR patients, bone scintigraphy as a semiquantitative test of myocardial amyloid burden was performed as previously described., Cardiac retention of 99mTc-DPD was visually scored as: Grade 0 – no myocardial uptake; Grade 1 – mild cardiac uptake with no significant attenuation of normal bony uptake; Grade 2 – moderate cardiac uptake with some attenuation of the bone signal; Grade 3 – strong cardiac uptake with little or no bone uptake.

Statistical analysis

A statistical package (SPSS, version 22) was used for all data analysis. Continuous variables were expressed as mean ± SD and non-parametric variables as median with inter-quartile. The association between ECVCT and ECVCMR was assessed by using Pearson correlation; normal distribution was assessed by using the Shapiro Wilkinson test. Agreement between ECVCT and ECVCMR was assessed by Bland-Altman comparison. A p value <0.05 was considered statistically significant.

Results

Baseline characteristics of twenty-six systemic amyloidosis and twenty-seven AS patients are shown in Table 1. Compared to AS, patients with amyloidosis had a significantly higher LV mass (116 ± 40 vs 103 ± 27 g/m2; p = 0.05), higher indexed left atrial area (15.3 ± 3.4 vs 13.2 ± 3.7 cm2/m2; p = 0.05), lower LVEF (59 ± 15 vs 69 ± 13%; p = 0.02), lower indexed stroke volume (42 ± 10 vs 50 ± 13 ml/m2; p = 0.04), worse diastolic function (E/A ratio: 1.46 ± 0.94 vs 0.93 ± 0.55 ml/m2; p = 0.02) and shorter distance on 6-minute walk test (356 ± 136 vs 469 ± 168 m; p = 0.01). There was no significant between group difference in systolic or diastolic blood pressure, NT-proBNP or Troponin.

Technical development: DynEQ-CT ECV performance at 5 and 15 minutes

Comparison of the signal to noise ratios showed that the SNR was significantly higher in the 5 minute rather than 15 minute scan (4.7 ± 0.9 vs 3.9 ± 0.9, p<0.001). ECVCT at 5 minutes was strongly correlated with ECVCMR (r2 = 0.85, p<0.001) but correlation was weaker at 15 minutes (r2 = 0.74, p<0.001; Fig. 3). Bland-Altman comparisons of ECVCT and ECVCMR demonstrated no bias at 5 minutes post contrast, with slight bias at 15 minutes (4%, no slope). Compared to the 5 minute time point, the 95% confidence limits were nearly twice as wide at 15 minutes (95% confidence limits: −18%, 22% vs −11%, 11%).

The mean total calculated effective radiation dose for the whole DynEQ-CT protocol (including both post contrast time points) was 1.56 mSv ± 0.58 mSv, with a mean administered total Iodixanol (Visipaque) volume of 78 mL ± 11 mL.

For DynEQ-CT, inter- and intra-observer agreement was excellent for myocardial (ICC = 0.92 and ICC = 0.94, respectively) and blood pool (ICC = 0.96 and ICC = 0.99, respectively) attenuation measurements. Similarly for ECV, excellent agreement was found (ICC = 0.95 and ICC = 0.98, respectively).

Diagnosis of cardiac amyloid by ECV

ECVCT was significantly higher in amyloid patients with definitive cardiac involvement than aortic stenosis (0.54 ± 0.11 versus 0.28 ± 0.04, p<0.001; Fig. 4). Like ECVCMR, ECVCT discriminated 100% between amyloid patients with definitive cardiac involvement and patients with aortic stenosis (ie there was no overlap in ECV between the two cohorts). Furthermore, ECVCT showed a higher ECV in ATTR than AL amyloidosis (0.56 ± 0.11 versus 0.43 ± 0.12, p = 0.03), but with wide overlap between groups.

ECV tracks clinical parameters

ECVCT tracked clinical parameters as equally well as CMR, with DynEQ-CT ECV at 5 minutes consistently better than at 15 minutes (Table 2): for the 5 minute results, ECVCT increased with increasing index LV mass (r = 0.43, p = 0.003), increasing indexed LAA (r = 0.49, p = 0.001), lower LV ejection fraction (r = −0.45, p = 0.002), worse LV diastolic function (E/A ratio: r = 0.51, p<0.001), reduced distance on 6MWT (r = 0.35, p = 0.02), increasing NT-pro-BNP levels (r = 0.66, p = 0.001) and Troponin T levels (r = 0.49, p = 0.03). In ATTR amyloid, ECVCT tracked amyloid burden semi-quantitatively measured by DPD bone scintigraphy (p<0.001) (Fig. 5).

Discussion

This study showed that measuring the myocardial extracellular volume, ECVCT, using a simple 5-minute, gated cardiac CT protocol, DynEQ-CT, can distinguish cardiac amyloidosis from another disease with myocardial hypertrophy, aortic stenosis. ECVCT is a quantitative parameter and compares well with the previously validated standard of ECVCMR but is easier and quicker to measure. ECVCT tracked cardiac amyloid burden, which is a major marker of outcome in systemic amyloidosis. This protocol can simply be added to routine CT coronary angiography protocols with only a small increase in radiation dose. It has the potential to offer a unique insight into the myocardial interstitium and provide a new diagnostic test for an under-diagnosed and now treatable cause of LVH and heart failure: cardiac amyloidosis.

Our previous protocol using a primed infusion to reach contrast equilibrium was logistically cumbersome and time consuming, therefore development of a bolus-only approach brings ECV, this promising novel biomarker, a step closer to routine clinical applicability. In our paper we show disease-specific utility of the CT approach. Furthermore, we unequivocally demonstrated that imaging at 5 minutes post bolus was superior to acquisition at 15 minutes, with superior SNR, correlation to the ECVCMR, correlation to clinical parameters known to track cardiac disease, and to semiquantitative bone tracer scanning results in TTR amyloid. The theoretical advantage of allowing equilibration of the iodine concentration in myocardium and blood between the 5 minute and 15 minute scan is out-weighed by the loss in signal due to overall lower iodine concentrations. Peculiar to cardiac amyloid, as the ECV is so high, early post contrast images may not allow easy identification of the boundary between myocardium and blood. This is due to the myocardial ECV being as high or even higher than that of the plasma such that pre and post contrast attenuation are very similar. The addition of a low dose, early arterial phase scan facilitated blood myocardial segmentation overall. The resulting triple phase scan using a 64 slice scanner had a mean overall radiation dose of 1.5 mSv – significantly lower than conventionally used bone tracer scintigraphy (4 mSv).

Comparison to previous CTECV work is limited to two studies by Nacif and colleagues comparing heart failure patients with controls: In the first study, subjects underwent CMR and CCT with CTECV and yielding results in line with the CMR ECV literature and similar to our AS cohort (28.6 ± 4.4% vs 31.6 ± 5.1%, p = 0.03). In the second study, whole heart 3D ECV was quantified; ECV was substantially higher than in the previous CT study by the same group and in CMRECV studies (41 ± 6%, 33 ± 2%; p = 0.02), raising the concern that the partial voluming of the blood pool may have occurred. In this context, our CT ECV results in confirmed cardiac amyloidosis were 6 standard deviations higher than in the control subjects.

From a diagnostic perspective, ECVCT was higher in patients with definite cardiac amyloidosis than the comparator group with LVH due to AS with no overlap, which mirrored previous findings by ECVCMR. Furthermore, ECVCT correlated with established markers of cardiac amyloid severity using structural and functional (LVEF and SV) parameters, biomarkers, and function capacity as well as cardiac amyloid burden measured semi-quantitatively by bone tracer scintigraphy. Although the role of cellular hypertrophy and diffuse fibrosis is unknown in cardiac amyloid, the ECV expansion seen with amyloid deposition is ten times larger than that seen with diffuse fibrosis in aortic stenosis, hypertension or hypertrophic cardiomyopathy.,,

The ECVCT technique carries some advantages in clinical practice; CMR is not suitable in around 10% of patients (due to claustrophobia or many cardiac pacemakers). Furthermore, there are concerns that the CMR signal is affected by limits to the fast exchange of protons (this does not apply to CT). The CT approach is cheaper, completed in 5 minutes, and widely available, providing high-resolution 3D ECV volumes with two single breath-hold acquisitions, and the scanner design can accommodate patients with obesity and claustrophobia. Although it has a lower signal to noise ratio, and probably more dependency on a reasonable eGFR, ECVCT therefore has several advantages over ECVCMR.

Limitations and future steps

In this study, the DynEQ-CT technique was compared to the best, currently available non-invasive techniques for the quantification of ECV (EQ-CMR) and TTR amyloid burden (DPD scintigraphy), but no invasive biopsy data was available for this validation. However, with the patchy distribution of cardiac amyloid deposits, biopsy data may not be superior. DynEQ-CT and EQ-CMR only identify general cardiac amyloid deposition (which is important to trigger therapy); tissue diagnosis is still necessary, but can be achieved from more accessible, non-cardiac tissue in this systemic disease. The data presented here is from a small study in a single specialized center, aimed to be hypothesis generating. A larger study is required to test these, develop this test further, and compare the head-to-head diagnostic performance of CT and CMR. The 64-slice-CT-system employed here may reflect the most commonly available systems available, but does not take advantage of newer systems that offer iterative reconstruction algorithms, dual energy acquisition and larger detector arrays that allow acquisition of whole heart, isotropic volumes of in one heart beat and at low radiation dose. In conjunction with 3D image registration and processing, this allows creation of whole heart ECV maps. Given the exposure to ionizing radiation, patients with severe aortic stenosis were deemed as adequate control cohort, avoiding exposure of healthy volunteers. Furthermore, AS patients were age-/gender-matched and had ventricular hypertrophy. As a research project, we limited the study to subjects with an eGFR of >60, a significant limitation for AL amyloid where 50% of patients with significant amyloid have renal impairment.

Conclusion

DynEQ-CT is a simple 5-minute, gated, easily implementable contrast-enhanced cardiac CT scan that can quantify cardiac amyloid burden, track disease severity and appears to be as effective as cardiovascular MR. Advantages over cardiovascular MR include scanner availability and cost, reduced examination time and applicability to those with CMR contraindications.

Disclosures

All authors have reported that they have no relationships relevant to the contents of this paper to disclose.

Source of funding

T.A.T and S.B. are supported by Doctoral Research Fellowships from the NIHR, UK (NIHR-DRF- 2013-06-102/NIHR-DRF- 2011-04-008). M.F and S.K.W. are supported by Clinical Research Training Fellowships from the British Heart Foundation (grants FS/12/56/29723 and FS/10/72/28568). J.C.M. has received grant funding from GlaxoSmithKline. Stuart Taylor is an NIHR senior investigator. This work was undertaken at University College London Hospital, which received a proportion of funding from the UK Department of Health National Institute for Health Research Biomedical Research Centers funding scheme.

References 26

  1. 1.
  2. 2.

    Merlini G., Bellotti V. Molecular mechanisms of amyloidosis. N Engl J Med. 2003;349:583-596.

    Not in our library10.1056/nejmra023144

  3. 3.

    Ng B., Connors L.H., Davidoff R., Skinner M., Falk R.H. Senile systemic amyloidosis presenting with heart failure: a comparison with light chain-associated amyloidosis. Arch Intern Med. 2005;165:1425-1429.

    Not in our library10.1001/archinte.165.12.1425

  4. 4.

    Dubrey S.W., Cha K., Skinner M., LaValley M., Falk R.H. Familial and primary (al) cardiac amyloidosis: Echocardiographically similar diseases with distinctly different clinical outcomes. Heart. 1997;78:74-82.

    Not in our library10.1136/hrt.78.1.74

  5. 5.

    Rapezzi C., Merlini G., Quarta C.C. Systemic cardiac amyloidoses: disease profiles and clinical courses of the 3 main types. Circulation. 2009;120:1203-1212.

    Not in our library10.1161/circulationaha.108.843334

  6. 6.

    Hanna M. Novel drugs targeting transthyretin amyloidosis. Curr Heart Fail Rep. 2014 Mar;11(1):50-57.

    Not in our library10.1007/s11897-013-0182-4

  7. 7.

    Wechalekar A.D., Hawkins P.N. Al amyloidosis: new drugs and tests, but old challenges. Oncology (Williston Park). 2012;26.

    Not in our library

  8. 8.

    Syed I.S., Glockner J.F., Feng D. Role of cardiac magnetic resonance imaging in the detection of cardiac amyloidosis. JACC Cardiovasc Imaging. 2010;3:155-164.

    Not in our library10.1016/j.jcmg.2009.09.023

  9. 9.
  10. 10.

    Perugini E., Guidalotti P.L., Salvi F. Noninvasive etiologic diagnosis of cardiac amyloidosis using 99mtc-3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy. J Am Coll Cardiol. 2005;46:1076-1084.

    Not in our library10.1016/j.jacc.2005.05.073

  11. 11.

    Hutt D.F., Quigley A.M., Page J. Utility and limitations of 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy in systemic amyloidosis. Eur Heart J Cardiovasc Imaging. 2014.

    Not in our library10.1093/ehjci/jeu107

  12. 12.
  13. 13.

    Banypersad S.M., Sado D.M., Flett A.S. Quantification of myocardial extracellular volume fraction in systemic al amyloidosis: an equilibrium contrast cardiovascular magnetic resonance study. Circ Cardiovasc Imaging. 2013;6:34-39.

    Not in our library10.1161/circimaging.112.978627

  14. 14.

    Bandula S., White S.K., Flett A.S. Measurement of myocardial extracellular volume fraction by using equilibrium contrast-enhanced ct: validation against histologic findings. Radiology. 2013;269:396-403.

    Not in our library10.1148/radiology.13130130

  15. 15.

    Nacif M.S., Kawel N., Lee J.J. Interstitial myocardial fibrosis assessed as extracellular volume fraction with low-radiation-dose cardiac ct. Radiology. 2012;264:876-883.

    Not in our library10.1148/radiol.12112458

  16. 16.

    Nacif M.S., Liu Y., Yao J. 3d left ventricular extracellular volume fraction by low-radiation dose cardiac ct: assessment of interstitial myocardial fibrosis. J Cardiovasc Comput Tomogr. 2013;7:51-57.

    Not in our library10.1016/j.jcct.2012.10.010

  17. 17.

    Nagueh S.F., Appleton C.P., Gillebert T.C. Recommendations for the evaluation of left ventricular diastolic function by echocardiography. Eur J Echocardiogr. 2009;10:165-193.

    Not in our library10.1093/ejechocard/jep007

  18. 18.

    Gertz M.A., Comenzo R., Falk R.H. Definition of organ involvement and treatment response in immunoglobulin light chain amyloidosis (al): a consensus opinion from the 10th international symposium on amyloid and amyloidosis, tours, france, 18-22 april 2004. Am J Hematol. 2005;79:319-328.

    Not in our library10.1002/ajh.20381

  19. 19.

    Fontana M., Banypersad S.M., Treibel T.A. Native t1 mapping in transthyretin amyloidosis. JACC Cardiovasc Imaging. 2014;7:157-165.

    Not in our library10.1016/j.jcmg.2013.10.008

  20. 20.

    Hausleiter J., Meyer T., Hermann F. Estimated radiation dose associated with cardiac ct angiography. Jama. 2009;301:500-507.

    Not in our library10.1001/jama.2009.54

  21. 21.
  22. 22.

    Flett A.S., Hayward M.P., Ashworth M.T. Equilibrium contrast cardiovascular magnetic resonance for the measurement of diffuse myocardial fibrosis: preliminary validation in humans. Circulation. 2010;122:138-144.

    Not in our library10.1161/circulationaha.109.930636

  23. 23.
  24. 24.

    Sado D.M., Flett A.S., Banypersad S.M. Cardiovascular magnetic resonance measurement of myocardial extracellular volume in health and disease. Heart. 2012;98:1436-1441.

    Not in our library10.1136/heartjnl-2012-302346

  25. 25.

    Kuruvilla S., Janardhanan R., Antkowiak P. Increased extracellular volume and altered mechanics are associated with lvh in hypertensive heart disease, not hypertension alone. JACC Cardiovasc Imaging. 2015;8:172-180.

    Not in our library10.1016/j.jcmg.2014.09.020

  26. 26.

    Brouwer W.P., Baars E.N., Germans T. In-vivo t1 cardiovascular magnetic resonance study of diffuse myocardial fibrosis in hypertrophic cardiomyopathy. J Cardiovasc Magn Reson. 2014;16:28.

    Not in our library10.1186/1532-429x-16-28

Cited by papers we hold 5

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.