Frequency and reason for reoperation following non-invasive expandable endoprostheses: A systematic review
Johnathan R. Lex, Amirul Adlan, Kim Tsoi and 2 more
Journal of Bone Oncology · 2021
doi:10.1016/j.jbo.2021.100397 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Background: Non-invasive expandable endoprostheses (NIEPR) utilize an external electromagnetic field to drive an innate mechanical gearbox. This lengthens the extremity following oncological resections in children with a predicted limb length discrepancy (LLD), facilitating limb-salvage. This review was conducted to assess NIEPR implant survival rates and identify modes of implant failure unique to these prostheses. Methods: Medline, EMBASE and the Cochrane Library databases were searched for all manuscripts evaluating implant survival of NIEPRs implanted into skeletally immature patients following resection of extremity sarcomas. Minimum follow-up of 12 months or implant failure was required for inclusion. Failures were classified using the latest ISOLS classification and exact implant-specific failure modality was also identified. Results: 19 studies met inclusion criteria. Mean age was 10.0 years (7.7 – 11.4 years). The most common locations for NIEPR implantation were the distal femur (343, 76.7%) and proximal tibia (53, 119%). Mean follow-up was 65.3 months (19.4 – 163 months). The overall implant revision rate was 46.2% (0 – 100%); implant specific revisions included maximal prosthesis lengthening with persistent LLD (10.4%), failed extension mechanism (6.1%), implant fracture (7.7%), hinge fracture (1.4%) and bushing wear (0.9%). Persistent clinically significant (>20 mm) LLD at final follow-up was present in 19.2% (0 – 50%) of patients. The mean MSTS score was 85.1% (66.7–96.3%) at final follow-up. Conclusion: Implant-related failures are the most common reason for NIEPR revision. Implant reliability appears to be improved with current designs. A sub-classification to the current classification system based on implant-specific failures for NIEPRs is proposed.
Abstract licence: CC BY-NC
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.