Skip to content
naulon
Not checkedNot checked for notices yet.

The assessment of pulmonary vein potentials using the new achieve advance during cryoballoon ablation of atrial fibrillation

Giacomo Mugnai, Massimiliano Manfrin, Carlo de Asmundis and 6 more

Indian Pacing and Electrophysiology Journal · 2019

doi:10.1016/j.ipej.2019.06.004 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Background: The new version of inner lumen mapping catheter (Achieve Advance™; Medtronic, Minnesota, USA) includes a new solid core which provides improved rotational response, as compared to the current Achieve Mapping Catheter. In the present study, we sought to analyze the rate of visualisation of real-time recordings using this new device comparing it with a large cohort of patients having undergone second generation cryoballoon (CB) ablation using the previous Achieve mapping catheter. Methods: All patients having undergone CB ablation using the Achieve Advance and the last 150 consecutive patients having undergone CB ablation using the previous Achieve were analysed. Exclusion criteria were presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease and contraindications to general anesthesia. Results: A total of 200 consecutive patients (60.1 ± 9.5 years, 75% males) were evaluated (50 Achieve Advance and 150 old Achieve). Real-time recordings were significantly more prevalent in the “new Achieve Advance” population compared with the “old Achieve” group (73.5% vs 56.8%; p = 0.0001). Real-time recordings could be more frequently visualized in the “Achieve Advance” group in all veins except RIPV (LSPV: 86% vs 71.3%, p = 0.04; LIPV: 84% vs 62.7%, p = 0.005; RSPV: 78% vs 52%, p < 0.0001; RIPV: 46% vs 41.3%, p = 0.3). Conclusions: The rate of visualisation of real-time recordings is significantly higher using the new Achieve Advance if compared to the previous Achieve mapping catheter in the setting of CB ablation. Real-time recordings can be visualized in approximately 73.5% of veins with this new device. Keywords: Atrial fibrillation, Achieve, Catheter ablation, Pulmonary vein isolation

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.