Skip to content
naulon
Not checkedNot checked for notices yet.

Comparative evaluation of the Alpha Tec ® NAC-PAC™ Red against a conventional NALC-NaOH method for decontamination of sputum samples for tuberculosis testing

S. Nomatshaka, N. Govender, R. Kwapu and 3 more

International Journal of Infectious Diseases · 2014

doi:10.1016/j.ijid.2014.03.1183 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Background: Decontamination methods for M. tuberculosis (MTB) diagnostics have evolved from robust methods to well formatted platforms with visualization of neutralization as well as decreased culture contamination rates. The NAC-PAC™ Red (Alpha Tec, USA) is a new commercial decontamination method that contains NAC-PAC Red™ (Sodium hydroxide) 3%, N-acetyl-L-cysteine (NALC) 300 mg, NPC-67™ neutralization buffer and a pellet resuspension buffer with reported enhanced recovery of mycobacteria and lower contamination rates from processed sputum samples. Methods & Materials: A comparative evaluation of 780 sputum samples from suspected MTB infected patients was performed. Samples were categorized according to time to processing (old > 3 days, new ≤ 3 days) and randomized into batches of 30 and processed with either NAC-PAC™ Red or another conventional NALC-NaOH method. Percentage agreement among the two methods was determined. Results: The NAC-PAC™ Red method for the old samples (N = 210), compared to the new samples (N = 210), yielded a MTB culture positivity of 13.8% and 10.4% respectively and a culture contamination rate of 12.3% and 11.9% respectively. The conventional method for the old samples (N = 150), compared to the new samples (N = 210), yielded a MTB culture positivity of 9.3% and 9.5% respectively and a culture contamination rate of 16.6% and 8% respectively. Percentage agreement for recovery of M. tuberculosis for both methods, old samples and the new samples, was 67.4% and 91.5% respectively. Conclusion: The NAC-PAC™ Red method showed a higher MTB recovery rate and lower contamination rate from the old samples with similar results from new samples compared to the conventional method. This method can be recommended for use as an alternative to other conventional decontamination methods with the added benefit of a higher recovery and lower contamination rate of samples with a delayed processing time.

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.