Not checkedNot checked for notices yet.
Occupational radiation dose to the lens of the eye of medical staff who assist in diagnostic CT scans
Keisuke Nagamoto, Takashi Moritake, Koichi Nakagami and 5 more
Heliyon · 2021
doi:10.1016/j.heliyon.2021.e06063 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Purpose: We investigated occupational dose to the lens of the eye for CT-assisting personnel for diagnostic purposes using a radio-photoluminescent glass dosimeter (RPLD) and evaluate compliance with the new equivalent dose limit for the lens of the eye (20 mSv/year). Further, we proposed the implementation of “multiple protective measures” and estimated its effect. Method: An eye lens dosimeter clip was developed specifically to attach RPLDs inside radiation safety glasses in an L-shape. Using a total of six RPLDs attached to the radiation safety glasses, the 3-mm dose-equivalent (Hp(3)) to the lens of the eye for medical staff (n = 11; 6 intensive care physicians, 2 pediatricians, 3 radiological technologists) who assisted patients during CT scan for “diagnostic” purpose (n = 91) was measured. We evaluated the dose reduction efficiencies with radiation safety glasses and bag-valve-mask extension tube. We also estimated the protection efficiency with radiation protection curtain introduced in front of the staff's face via the phantom experiment. Results: Without wearing radiation safety glasses, Hp(3) to the lens of the eye was greatest for intensive care physicians (0.49 mSv/procedure; allowing 40 procedures to be performed annually), followed by pediatricians (0.30 mSv/procedure; 66 procedures annually) and radiological technologists (0.28 mSv/procedure; 71 procedures annually). Use of each type of protective tools: radiation safety glasses (0.07-mm-Pb), bag-valve-mask extension tube (20 cm) and radiation protective curtain (0.25-mm-Pb), reduced Hp(3) to the lens of the eye by 51%, 31% and 61%, respectively. Conclusion: Intensive care physicians perform most assisted ventilations with the bag-valve-mask during “diagnostic” CT scans, and may exceed the equivalent dose limit for the lens of the eye if radiation safety glasses are not worn. If “multiple protective measures” are implemented, compliance with the equivalent dose limit for the lens of the eye should be achievable without placing significant burdens on physicians or medical institutions.
Abstract licence: CC BY-NC
References40
- 28.
39 more references, whose wording the paper’s licence keeps private.
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.