Effects of low-frequency stimulation of the subthalamic nucleus on movement in Parkinson's disease

Alexandre Eusebio, Chiung Chu Chen, Chin Song Lu and 5 more

Experimental Neurology · 2008 · CC BY

doi:10.1016/j.expneurol.2007.09.007

Abstract

Excessive synchronization of basal ganglia neural activity at low frequencies is considered a hallmark of Parkinson's disease (PD). However, few studies have unambiguously linked this activity to movement impairment through direct stimulation of basal ganglia targets at low frequency. Furthermore, these studies have varied in their methodology and findings, so it remains unclear whether stimulation at any or all frequencies < or = 20 Hz impairs movement and if so, whether effects are identical across this broad frequency band. To address these issues, 18 PD patients chronically implanted with deep brain stimulation (DBS) electrodes in both subthalamic nuclei were stimulated bilaterally at 5, 10 and 20 Hz after overnight withdrawal of their medication and the effects of the DBS on a finger tapping task were compared to performance without DBS (0 Hz). Tapping rate decreased at 5 and 20 Hz compared to 0 Hz (by 11.8+/-4.9%, p=0.022 and 7.4+/-2.6%, p=0.009, respectively) on those sides with relatively preserved baseline task performance. Moreover, the coefficient of variation of tap intervals increased at 5 and 10 Hz compared to 0 Hz (by 70.4+/-35.8%, p=0.038 and 81.5+/-48.2%, p=0.043, respectively). These data suggest that the susceptibility of basal ganglia networks to the effects of excessive synchronization may be elevated across a broad low-frequency band in parkinsonian patients, although the nature of the consequent motor impairment may depend on the precise frequencies at which synchronization occurs.

Full text

From PubMed Central, U.S. National Library of Medicine, as current on Oct 24, 2026. Paragraph numbers are ours, so an answer can point at one.

Introduction

There is extensive evidence that neuronal activity is abnormally synchronized at low frequencies in Parkinson's disease (PD) and in animal models of parkinsonism (reviewed in ). However, this does not, by itself, prove that pathological synchrony is mechanistically important in parkinsonism. More persuasive evidence would be the impairment of voluntary movement by the artificial synchronization of neural activity in the basal ganglia. Such synchronization is possible by stimulating deep brain electrodes implanted for the treatment of PD at low frequencies, rather than at those frequencies above 100 Hz used for therapeutic benefit. Electrical stimulation of surgical targets like the subthalamic nucleus (STN) simultaneously activates neural elements in the vicinity of the electrode and this synchronous activity is then propagated onwards, as evinced by evoked pallidal, cortical and muscular activity.

So far there have been several reports of the impairment of movement by stimulation of the STN at frequencies ≤ 20 Hz in patients with PD. and studied finger tapping during DBS at 5 Hz and 20 Hz, respectively, and found this to be slowed. However,, using the motor United Parkinson's Disease rating scale (UPDRS), failed to confirm a worsening during DBS at 5 and 20 Hz, but did find increased bradykinesia with stimulation at 10 Hz. Another study evaluated tapping performance over several frequencies within the same patients, but only found weak effects that involved relative rather than absolute impairments in motor performance, superimposed upon an overall tendency for movement to improve with increasing stimulation frequency. Accordingly, it is unclear whether stimulation at any or all frequencies ≤ 20 Hz impairs movement and if so, whether effects are identical across this broad frequency band. The issue is an important one, as although spontaneous synchrony tends to occur at frequencies centered around 20 Hz in PD, it occurs at rather lower frequencies in the 1-methyl-4-phenyl-1,2,3,6,-tetrahydropyridine (MPTP) primate model of PD.

Here we contrast the effects of STN stimulation and thereby extrinsically imposed synchronization at a number of frequencies ≤ 20 Hz, to establish whether all such frequencies impair movement and, if so, whether they impair movement in the same way. To this end we studied performance in a simple finger tapping task, as this is objective and correlates with motor impairment, and considered changes in task execution according to baseline performance.

Patients and surgery

Twenty patients participated with informed consent and the permission of the local ethics committees (5 females, mean age 59.5 ± 1.4 years; mean disease duration 13.5 ± 1.0 years). Their clinical details are summarized in Table 1. Fourteen of these patients had also been recorded at least 6 months previously in a different paradigm involving stimulation at 20 Hz, 50 Hz and 130 Hz. Implantation of bilateral STN DBS electrodes was performed in all subjects for treatment of Parkinson's disease at least 6 months prior to study (mean 34.7 ± 5.9 months). The DBS electrode used was model 3389 (Medtronic Neurological Division, Minneapolis, USA) with four platinum–iridium cylindrical surfaces (1.27 mm diameter and 1.5 mm length) and a centre-to-centre separation of 2 mm. Contact 0 was the most caudal and contact 3 was the most rostral. The intended coordinates at the tip of contact 0 were 10–12 mm from the midline, 0–2 mm behind the midcommissural point and 3–5 mm below the anterior commissural–posterior commissural line. Adjustments to the intended coordinates were made in accordance with the direct visualization of STN in individual stereotactic MRI and, in the patients operated in Taiwan (n = 7), the results of microelectrode recordings. Correct placement of the DBS electrodes in the region of the STN was further supported by: [1] effective intra-operative macrostimulation; [2] post-operative T2-weighted MRI compatible with the placement of at least one electrode contact in the STN region; [3] significant improvement in UPDRS motor score during chronic DBS off medication (22.7 ± 3.0) compared to UPDRS off medication with stimulator switched off (52.6 ± 4.8; p < 0.00001, paired t-test). One patient was excluded due to the absence of significant improvement in UPDRS motor score during chronic DBS and another one due to missing clinical data.

Protocol

All patients were assessed after overnight withdrawal of antiparkinsonian medication, although the long action of many of the drugs used to treat PD meant that patients may still have been partially treated when assessed. They were studied when the stimulator was switched off and during bilateral STN stimulation at 5 Hz, 10 Hz and 20 Hz. The stimulation types were assessed in pseudo-randomized order across patients, as was the presentation order of trials within a stimulation type. Stimulation contacts, amplitude and pulse duration were the same as utilized for therapeutic high frequency stimulation in each subject (see Table 1). There was no evidence of capsular spread during stimulation, as determined by clinical examination. Patients were not informed of the stimulation type. We did not stimulate one side at a time to avoid possible functional compensation by the non-stimulated side. We waited 20 min after changing between conditions before testing. This is sufficient time to elicit about 75% of DBS effects.

Task

The task was repetitive depression of a keyboard key as fast as possible by rapid alternating flexion and extension of the index finger at the level of the metacarpophalangeal joint. Tapping was performed in two runs of 30 s, separated by ∼ 30-s rest and each hand tested separately (giving four runs per condition). Data from one side were rejected as these were collected contralateral to a previous unilateral pallidotomy (case 18 in Table 1). The number of taps made with the index finger in 30 s was recorded and the run from each pair with the best performance selected for analysis, as this was less likely to be affected by fatigue, or the effects of impaired arousal/concentration.

Statistics

The results of the tapping task in patients were analyzed according to their baseline performance (e.g. without stimulation). The lower limit of normal baseline performance was obtained by testing ten healthy age matched control subjects (20 sides, 4 males, mean age 57 years, range 52–64 years) using the same tapping task. The mean tapping rate in this control group was 162 taps/30 s. The lower limit of the normal range (e.g. mean − [2 × standard deviation]) in this control group was 127 taps per 30 s. The 35 tapping sides studied in the 18 patients were accordingly divided into those with baseline performance within normal limits (n = 17; the mean tapping performance across this group, 157 taps/30 s, was still lower than the mean tapping performance in healthy subjects) and those with baseline tapping rates lower than normal limits (n = 18; mean tapping performance 58 taps/30 s). The rationale behind this approach was to select those sides (with baseline performance within normal limits) in which any deleterious effects of DBS would not be overshadowed by the beneficial effects of DBS-induced suppression of spontaneous pathological activity or limited by floor effects due to major baseline impairment. Four subjects had sides distributed across the two groups of differing baseline tapping performance. Tapping rates and coefficients of variation were normally distributed (one-sample Kolmogorov–Smirnov tests, p > 0.05). Repeated-measures ANOVAs with within-subjects simple contrasts (comparing different frequencies of stimulation to no stimulation) were performed in SPSS (SPSS for Windows version 11, SPSS Inc., Chicago, IL, USA). Mauchly's test was used to determine the sphericity of the data entered in the ANOVAs, and where data were non-spherical Greenhouse–Geisser corrections applied. Means ± standard error of the means are presented in the text.

Results

Low-frequency stimulation had no reliable clinical effect and did not consistently induce tremor, mobile dyskinesia, or dystonic posturing. Four patients experienced dystonic postures during the experiment and one had increased tremor. However, these effects were seen for overlapping stimulation frequencies. We divided the tapping sides into two groups according to whether or not tapping performance off DBS was within normal limits established on 20 sides in 10 healthy age-matched subjects (see Materials and methods). ANOVA of tapping scores with factors FREQUENCY (four levels: 0, 5, 10 and 20 Hz) and BASELINE TAPPING PERFORMANCE (two levels: within normal limits and less than normal limits) demonstrated a within-subjects interaction between FREQUENCY and BASELINE TAPPING PERFORMANCE (F[3,48] = 4.224, p = 0.01). Data were further analyzed with separate ANOVAs in each baseline tapping performance group. In those patients with baseline tapping performance within normal limits, ANOVA with the factor FREQUENCY confirmed that the latter was a significant main effect (F[3,48] = 3.777, p = 0.016). Within-subjects contrasts indicated that tapping during 5 and 20 Hz stimulation was worse than during no stimulation (F[1,16] = 6.385, p = 0.022 and F[1,16] =8.793, p = 0.009, respectively). The average deterioration in tapping rate during 5 and 20 Hz stimulation compared to no stimulation (0 Hz) in this group was 11.8 ± 4.9% and 7.4 ± 2.6%, respectively (Fig. 1). There was a trend towards a decreased tapping performance at 10 Hz compared to 0 Hz (F[1,16] = 3.578, p = 0.077). There was no effect of FREQUENCY in patients with baseline tapping performance below normal limits (ANOVA, F[1.9,32.8] = 2.202, p = 0.128).

We also analyzed the variability in tapping as measured by the coefficient of variation (CV) of the time intervals between successive taps on those sides with baseline tapping performance within normal limits. ANOVA with the factor FREQUENCY (four levels: 0, 5, 10 and 20 Hz) revealed a significant effect of FREQUENCY (F[3,48] = 3.408, p = 0.025). Within-subjects contrasts indicated that the CV increased during 5 and 10 Hz stimulation compared with no stimulation (F[1,16] = 5.144, p = 0.038 and F[1,16] = 4.852, p = 0.043, respectively). The average increase of the CV during 5 and 10 Hz stimulation compared to 0 Hz in this group was 70.4 ± 35.8% and 81.5 ± 48.2%, respectively (Fig. 2). There was no difference between the CV at 20 Hz compared to 0 Hz (F[1,16] = 0.871, p = 0.365). There was, however, a trend for the CV with 5 Hz stimulation to exceed that with 20 Hz stimulation (t-test; p = 0.059).

Discussion

We have shown that STN DBS at a variety of low frequencies can slow distal upper limb movements in PD patients with relatively preserved baseline tapping function at the time of study. The effect was present with DBS at 5 Hz and 20 Hz in line with previous studies, and there was a trend towards a similar effect with stimulation at 10 Hz. These effects were apparent when tapping sides were separately analyzed according to whether the level of baseline performance was within or outside of normal limits, in line with previous studies suggesting that deleterious effects of DBS are more evident on those sides with relatively preserved baseline performance. The effect was not apparent during stimulation on those sides with impaired baseline performance, either because of confounding, albeit mild, suppressive effects of low-frequency DBS on spontaneous pathological oscillations or because of floor effects.

In principle, then, the susceptibility of basal ganglia–cortical loops to the effects of excessive synchronization may be elevated across a broad low-frequency band in parkinsonian patients. Accordingly, the relatively different frequency ranges of pathological synchronization in patients and MPTP-treated primates may be more indicative of the resonance properties of basal ganglia networks in the different situations, rather than any fundamental differences in the mechanism of bradykinesia. However, it must be stressed that this is a generalization, and although synchronization at different frequencies may conspire to disturb movement, there may still be subtle differences in the way movement is impaired. This is brought out by the differential effects of low-frequency stimulation on the variation in tapping intervals, evident in differences in the coefficient of variation and hence independent of any differences in tapping rate. Only DBS at 5 and 10 Hz increased temporal variability, whereas DBS at 20 Hz selectively decreased tapping rates without changing tapping variability.

The implication is that basal ganglia networks are involved in processing related to the temporal patterning and regularity of movement and that these circuits may be particularly susceptible to disruption by pathological synchronization at frequencies ≤ 10 Hz. In support of basal ganglia involvement in the temporal patterning of movement, PD patients have increased temporal variability in finger tapping, and temporal variability in motor performance is a very early feature of Huntington's disease. Indeed, Flowers considered increased variability of movement in both time and space to be one of the core components of motor dysfunction in PD, along with a basic slowness of movement, and a difficulty in initiating and maintaining movement. This variability in motor performance may also relate to the phenomenon of freezing. No overt freezing episodes were observed during tapping in our patients, but an increased variability of stride has been shown in PD patients experiencing freezing of gait independent of frank freezing episodes.

However, a primary disturbance of temporal patterning is not the only potential interpretation for the increased variability seen during stimulation at 5 Hz and 10 Hz. Tremor was not seen during low-frequency stimulation (except in one patient), in agreement with, nor were there any obvious and consistent dyskinesias. Nevertheless, it is possible that synchronization at frequencies ≤ 10 Hz induced subtle hyperkinesias that led to increased temporal variability across taps. A previous case report describes dyskinetic movements induced by STN DBS at 5 Hz, and there is increasing evidence that excessive synchronization over 4–10 Hz within basal ganglia circuits may be related to both levodopa-induced dyskinesias in PD and mobile elements of dystonia. Relevant in this regard, a recent study demonstrated an increased variability of speech rate in patients treated with l-DOPA and suggested that this effect was related to dyskinesia. Variability of swing movement was also observed in the gait of dyskinetic CP children.

In summary, our results provide further evidence that DBS of the STN over a relatively broad band of low frequencies can impair movement, in line with other more circumstantial evidence of an association between low-frequency synchrony in basal ganglia–cortical loops and altered movement (see recent reviews by ). The present results also raise the important possibility that the detailed profile of motor abnormalities evident in extrapyramidal diseases depends to some extent on the precise frequencies at which pathological synchronization occurs. Indeed, some differences in the details of the effects of pathological synchrony at different frequencies might be anticipated, given the evidence for selective tuning of basal ganglia–cortical sub-circuits.

References 32

  1. 1.

    Abel R., Rupp R., Sutherland D. Quantifying the variability of a complex motor task specifically studying the gait of dyskinetic CP children. Gait Posture. 2003;17:50-58.

    Not in our library10.1016/s0966-6362(02)00054-1

  2. 2.

    Alonso-Frech F., Zamarbide I., Alegre M., Rodriguez-Oroz M.C., Guridi J., Manrique M., Valencia M., Artieda J., Obeso J.A. Slow oscillatory activity and levodopa-induced dyskinesias in Parkinson's disease. Brain. 2006;129:1748-1757.

    Not in our library10.1093/brain/awl103

  3. 3.

    Ashby P., Kim Y.J., Kumar R., Lang A.E., Lozano A.M. Neurophysiological effects of stimulation through electrodes in the human subthalamic nucleus. Brain. 1999;122(Pt 10):1919-1931.

    Not in our library10.1093/brain/122.10.1919

  4. 4.

    Ashby P., Paradiso G., Saint-Cyr J.A., Chen R., Lang A.E., Lozano A.M. Potentials recorded at the scalp by stimulation near the human subthalamic nucleus. Clin. Neurophysiol. 2001;112:431-437.

    Not in our library10.1016/s1388-2457(00)00532-0

  5. 5.

    Brown P., Mazzone P., Oliviero A., Altibrandi M.G., Pilato F., Tonali P.A., Di Lazzaro V. Effects of stimulation of the subthalamic area on oscillatory pallidal activity in Parkinson's disease. Exp. Neurol. 2004;188:480-490.

    Not in our library10.1016/j.expneurol.2004.05.009

  6. 6.

    Chen C.C., Brucke C., Kempf F., Kupsch A., Lu C.S., Lee S.T., Tisch S., Limousin P., Hariz M., Brown P. Deep brain stimulation of the subthalamic nucleus: a two-edged sword. Curr. Biol. 2006;16:R952-R953.

    Not in our library10.1016/j.cub.2006.10.013

  7. 7.

    Chen C.C., Kuhn A., Trottenberg T., Kupsch A., Schneider G., Brown P. Neuronal activity in globus pallidus interna can be synchronized to local field potential activity over 3–12 Hz in patients with dystonia. Exp. Neurol. 2006;202:480-486.

    Not in our library10.1016/j.expneurol.2006.07.011

  8. 8.

    Chen C.C., Litvak V., Gilbertson T., Kuhn A., Lu C.S., Lee S.T., Tsai C.H., Tisch S., Limousin P., Hariz M., Brown P. Excessive synchronization of basal ganglia neurons at 20 Hz slows movement in Parkinson's disease. Exp. Neurol. 2007;205:214-221.

    Not in our library10.1016/j.expneurol.2007.01.027

  9. 9.

    De Letter M., Santens P., De Bodt M., Boon P., Van Borsel J. Levodopa-induced alterations in speech rate in advanced Parkinson's disease. Acta Neurol. Belg. 2006;106:19-22.

    Not in our library

  10. 10.

    Fogelson N., Kuhn A.A., Silberstein P., Limousin P.D., Hariz M., Trottenberg T., Kupsch A., Brown P. Frequency dependent effects of subthalamic nucleus stimulation in Parkinson's disease. Neurosci. Lett. 2005;382:5-9.

    Not in our library10.1016/j.neulet.2005.02.050

  11. 11.

    Fogelson N., Williams D., Tijssen M., van Bruggen G., Speelman H., Brown P. Different functional loops between cerebral cortex and the subthalmic area in Parkinson's disease. Cereb. Cortex. 2006;16:64-75.

    Not in our library10.1093/cercor/bhi084

  12. 12.

    Gatev P., Darbin O., Wichmann T. Oscillations in the basal ganglia under normal conditions and in movement disorders. Mov. Disord. 2006;21:1566-1577.

    Not in our library10.1002/mds.21033

  13. 13.

    Giovannoni G., van Schalkwyk J., Fritz V.U., Lees A.J. Bradykinesia akinesia inco-ordination test (BRAIN TEST): an objective computerised assessment of upper limb motor function. J. Neurol. Neurosurg. Psychiatry. 1999;67:624-629.

    Not in our library10.1136/jnnp.67.5.624

  14. 14.

    Goldberg J.A., Rokni U., Boraud T., Vaadia E., Bergman H. Spike synchronization in the cortex/basal-ganglia networks of Parkinsonian primates reflects global dynamics of the local field potentials. J. Neurosci. 2004;24:6003-6010.

    Not in our library10.1523/jneurosci.4848-03.2004

  15. 15.

    Hammond C., Bergman H., Brown P. Pathological synchronization in Parkinson's disease: networks, models and treatments. Trends Neurosci. 2007;30:357-364.

    Not in our library10.1016/j.tins.2007.05.004

  16. 16.

    Hariz M.I., Krack P., Melvill R., Jorgensen J.V., Hamel W., Hirabayashi H., Lenders M., Wesslen N., Tengvar M., Yousry T.A. A quick and universal method for stereotactic visualization of the subthalamic nucleus before and after implantation of deep brain stimulation electrodes. Stereotact. Funct. Neurosurg. 2003;80:96-101.

    Not in our library10.1159/000075167

  17. 17.

    Hashimoto T., Elder C.M., Okun M.S., Patrick S.K., Vitek J.L. Stimulation of the subthalamic nucleus changes the firing pattern of pallidal neurons. J. Neurosci. 2003;23:1916-1923.

    Not in our library10.1523/jneurosci.23-05-01916.2003

  18. 18.

    Hausdorff J.M., Schaafsma J.D., Balash Y., Bartels A.L., Gurevich T., Giladi N. Impaired regulation of stride variability in Parkinson's disease subjects with freezing of gait. Exp. Brain Res. 2003;149:187-194.

    Not in our library10.1007/s00221-002-1354-8

  19. 19.

    Hinton S.C., Paulsen J.S., Hoffmann R.G., Reynolds N.C., Zimbelman J.L., Rao S.M. Motor timing variability increases in preclinical Huntington's disease patients as estimated onset of motor symptoms approaches. J. Int. Neuropsychol. Soc. 2007;13:539-543.

    Not in our library10.1017/s1355617707070671

  20. 20.

    Liu X., Ford-Dunn H.L., Hayward G.N., Nandi D., Miall R.C., Aziz T.Z., Stein J.F. The oscillatory activity in the Parkinsonian subthalamic nucleus investigated using the macro-electrodes for deep brain stimulation. Clin. Neurophysiol. 2002;113:1667-1672.

    Not in our library10.1016/s1388-2457(02)00256-0

  21. 21.

    Liu X., Griffin I.C., Parkin S.G., Miall R.C., Rowe J.G., Gregory R.P., Scott R.B., Aziz T.Z., Stein J.F. Involvement of the medial pallidum in focal myoclonic dystonia: a clinical and neurophysiological case study. Mov. Disord. 2002;17:346-353.

    Not in our library10.1002/mds.10038

  22. 22.

    MacKinnon C.D., Webb R.M., Silberstein P., Tisch S., Asselman P., Limousin P., Rothwell J.C. Stimulation through electrodes implanted near the subthalamic nucleus activates projections to motor areas of cerebral cortex in patients with Parkinson's disease. Eur. J. Neurosci. 2005;21:1394-1402.

    Not in our library10.1111/j.1460-9568.2005.03952.x

  23. 23.

    Moro E., Esselink R.J., Xie J., Hommel M., Benabid A.L., Pollak P. The impact on Parkinson's disease of electrical parameter settings in STN stimulation. Neurology. 2002;59:706-713.

    Not in our library10.1212/wnl.59.5.706

  24. 24.

    Rabey J.M., Klein C., Molochnikov A., Van Hilten B., Krauss P., Bonuccelli U. Comparison of the Unified Parkinson's Disease Rating Scale and the Short Parkinson's Evaluation Scale in patients with Parkinson's disease after levodopa loading. Clin. Neuropharmacol. 2002;25:83-88.

    Not in our library10.1097/00002826-200203000-00005

  25. 25.

    Raz A., Feingold A., Zelanskaya V., Vaadia E., Bergman H. Neuronal synchronization of tonically active neurons in the striatum of normal and parkinsonian primates. J. Neurophysiol. 1996;76:2083-2088.

    Not in our library10.1152/jn.1996.76.3.2083

  26. 26.

    Raz A., Vaadia E., Bergman H. Firing patterns and correlations of spontaneous discharge of pallidal neurons in the normal and the tremulous 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine vervet model of parkinsonism. J. Neurosci. 2000;20:8559-8571.

    Not in our library10.1523/jneurosci.20-22-08559.2000

  27. 27.

    Sheridan M.R., Flowers K.A., Hurrell J. Programming and execution of movement in Parkinson's disease. Brain. 1987;110:1247-1271.

    Not in our library10.1093/brain/110.5.1247

  28. 28.

    Shimoyama I., Ninchoji T., Uemura K. The finger-tapping test. A quantitative analysis. Arch. Neurol. 1990;47:681-684.

    Not in our library10.1001/archneur.1990.00530060095025

  29. 29.

    Silberstein P., Kuhn A.A., Kupsch A., Trottenberg T., Krauss J.K., Wohrle J.C., Mazzone P., Insola A., Di Lazzaro V., Oliviero A., Aziz T., Brown P. Patterning of globus pallidus local field potentials differs between Parkinson's disease and dystonia. Brain. 2003;126:2597-2608.

    Not in our library10.1093/brain/awg267

  30. 30.

    Temperli P., Ghika J., Villemure J.G., Burkhard P.R., Bogousslavsky J., Vingerhoets F.J. How do parkinsonian signs return after discontinuation of subthalamic DBS? Neurology. 2003;60:78-81.

    Not in our library10.1212/wnl.60.1.78

  31. 31.

    Timmermann L., Wojtecki L., Gross J., Lehrke R., Voges J., Maarouf M., Treuer H., Sturm V., Schnitzler A. Ten–Hertz stimulation of subthalamic nucleus deteriorates motor symptoms in Parkinson's disease. Mov. Disord. 2004;19:1328-1333.

    Not in our library10.1002/mds.20198

  32. 32.

    Uhlhaas P.J., Singer W. Neural synchrony in brain disorders: relevance for cognitive dysfunctions and pathophysiology. Neuron. 2006;52:155-168.

    Not in our library10.1016/j.neuron.2006.09.020

Cited by papers we hold 9

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.