Case Studies in Thermal Engineering · 2022
doi:10.1016/j.csite.2022.102174 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Latent heat thermal energy storage systems exhibit a significant performance over other thermal energy storage systems. The performance of these particular systems during melting/solidification is influenced by their orientation. Therefore, a numerical investigation and experimental validation were conducted. ANSYS Fluent 18.1 is used to develop a numerical model to investigate the effects of the pipe's orientation angle. Parametric analysis of various pipe orientation angles (0°, 30°, 60°, 90°) and various oil inlet temperatures were conducted during the investigation. It was determined that the melting time and absorbed heat flux when the inlet temperature increased from 493 K to 523 K is reduced by 42% and increases by 59%, respectively. Furthermore, the solidification time decreases by 63% when the inlet temperature is reduced from 444 K to 413 K. Increasing the orientation angle of the pipe results in a reduction in the melt fraction by 16.5% as the orientation angle is increased from 0° to 90°. In addition, the orientation angle has a significant effect during the melting, which is influenced by increasing the orientation angle from 0° to 90° by 18.2%. Conversely, the orientation angle has no impact on solid fraction during solidification.
Abstract licence: CC BY-NC
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.