Concurrent TMS/fMRI with high sensitivity and accelerated image acquisition
Christian Windischberger, Maria Vasileiadi, Michael Woletz and 1 more
Brain Stimulation · 2021
doi:10.1016/j.brs.2021.10.444 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Functional magnetic resonance imaging (fMRI) has become the prime technique for non-invasive brain mapping as it yields high-resolution activation maps throughout the brain. Combined with TMS and applied simultaneously, concurrent TMS/fMRI offers the unique opportunity for directly assessing TMS-caused brain activity. Such, it is possible to study TMS effects across varying stimulation amplitude, protocol and targets. As changes in the BOLD fMRI signal are typically in range of only a few percent, high sensitivity acquisition is a prerequisite for successful TMS/fMRI. Standard concurrent TMS/fMRI setups are based on the use of single-channel, large-diameter birdcage coils that enable positioning of the TMS coil within the birdcage coil. In addition to their intrinsically low sensitivity, birdcage coils cannot be used with any of the various accelerated image acquisition methods used in MRI today, including parallel imaging (SENSE, GRAPPA) and multiband imaging (MB; simultaneous multi-slice, SMS). A different setup, based on thin, 7-channel receive arrays was recently proposed to overcome the shortcomings typical to birdcage coil setups [1,2]. Here we quantitatively assess the sensitivity of this new setup across a range of acquisition protocols. We also measure the effects of combining multiple receive-arrays for extended coverage. In particular, we show for the first time that it is possible to use three sets of 7-channel receive-arrays simultaneously to obtain unprecedentedly high sensitivity across the brain. References: 1: Navarro de Lara LI, et al. High-sensitivity TMS/fMRI of the Human Motor Cortex Using a Dedicated Multichannel MR Coil. Neuroimage. 2017; doi:10.1016/j.neuroimage.2017.02.062. 2: Navarro de Lara LI et al. A novel coil array for combined TMS/fMRI experiments at 3 T. Magn Reson Med. 2015 doi:10.1002/mrm.25535. Keywords: Concurrent TMS/fMRI, Interleaved TMS/fMRI, Neuroimaging
Abstract licence: CC BY-NC-ND
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.