P5.13 ESTIMATION OF CENTRAL SYSTOLIC PRESSURE: ARE PERIPHERAL WAVEFORMS AND TRANSFER FUNCTION NECESSARY?

Denis Chemla*, Sandrine Millasseau, Edmund Lau and 2 more

Artery Research · 2015

doi:10.1016/j.artres.2015.10.277 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Background and aim: The degree of systolic pressure amplification (SPamp) from aorta to brachial artery depends on a number of variables including age, gender, heart rate and arterial stiffness. It is admitted that central systolic blood pressure (cSBP) cannot be predicted with sufficient accuracy from brachial blood pressure and thus needs to be estimated using peripheral waveform analysis and transfer functions. We have developed a proprietary method for direct central blood pressure (DCBP) estimation, which challenges this paradigm. In the present preliminary study, our DCBP method was applied to a meta-analysis of published studies with invasive, high-fidelity pressure tip data of both aortic and brachial artery pressures. Methods and results: Five studies were found fulfilling our criteria. There were 282 subjects (77.3% male), with known or suspected coronary artery diseases. Mean age was 63.3±13.2years and heart rate was 67.1±11.3bpm. Invasive brachial systolic, diastolic and mean BP were 137.9±19.9mmHg, 70.9±10.2mmHg and 97.1±11.7mmHg, respectively. The measured invasive cSBP was 131.1±19.9mmHg and the mean SPamp was 6.8mmHg. The cSBP estimated with DCBP method was 132.9mmHg and the mean difference with invasive measures was 1.8mmHg. Conclusion: The meta-analysis of studies documenting invasive high-fidelity pressure at aortic and brachial artery level indicates that our DCBP method can predict cSBP from brachial blood pressures with good accuracy in relatively old subjects with established or suspected coronary diseases. Further studies are needed to document the precision of the DCBP method in healthier and younger subjects as well as its sensibility to peripheral BP measuring method.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.