No retraction, correction or concern found when last checked on Oct 17, 2026.
Frequently asked questions about in vivo chlorophyll fluorescence: practical issues
Hazem M. Kalaji, Gert Schansker, Richard J. Ladle and 26 more
Photosynthesis Research · 2014 · Review
Abstract
The aim of this educational review is to provide practical information on the hardware, methodology, and the hands on application of chlorophyll (Chl) a fluorescence technology. We present the paper in a question and answer format like frequently asked questions. Although nearly all information on the application of Chl a fluorescence can be found in the literature, it is not always easily accessible. This paper is primarily aimed at scientists who have some experience with the application of Chl a fluorescence but are still in the process of discovering what it all means and how it can be used. Topics discussed are (among other things) the kind of information that can be obtained using different fluorescence techniques, the interpretation of Chl a fluorescence signals, specific applications of these techniques, and practical advice on different subjects, such as on the length of dark adaptation before measurement of the Chl a fluorescence transient. The paper also provides the physiological background for some of the applied procedures. It also serves as a source of reference for experienced scientists.
Full text
From PubMed Central, U.S. National Library of Medicine, as current on Oct 17, 2026. Paragraph numbers are ours, so an answer can point at one.
Introduction
The measurement of chlorophyll (Chl) a fluorescence is one of the most widely used methods to probe photosynthesis (see Papageorgiou and Govindjee for reviews on application of Chl a fluorescence to different aspects of photosynthesis; also see Govindjee for an overview of important publications on Chl a fluorescence). Any researcher who tries to find his or her way in the fluorescence literature will initially be overwhelmed by the number of published articles and by all the conflicting ideas. Such a researcher will also quickly discover that it is not easy to find an answer for many simple and basic questions. We plan to fill this gap in this educational review focusing mainly on plants, green algae, and diatoms.
The Chl a fluorescence signal is very rich in its content; it is very sensitive to changes in photosynthesis and can be recorded with great precision. Many processes affect the fluorescence yield and/or intensity, and using a variety of light protocols (flashes, pulses, continuous light, etc.), different processes can be studied. However, most authors have used only a limited set of experimental protocols based on methods that have been developed over time.
With the available commercial equipment, it is very easy to make a fluorescence measurement, but as the literature shows, the interpretation of such measurements is still very contentious. There is not even agreement on the processes that determine the fluorescence rise from F O to F M, i.e., the variable fluorescence (F V). The dominant interpretation assumes that the variable fluorescence is determined by the redox state of Q A, the first quinone acceptor of PSII, as originally proposed by Duysens and Sweers and recently defended by Stirbet and Govindjee (2012). Delosme on the other hand argued that Q A was not enough and that there was another important process explaining part of F V. This position has recently been supported and extended by Schansker et al.; see Question 21 for a broader discussion of this point.
Another attractive feature of Chl a fluorescence is its non-invasive character, which allows the measurement on leaves and even on canopies of trees during long periods of time. A range of instruments has been developed focusing on different aspects of photosynthesis and on different properties of Chl a fluorescence. An overview will be given here of the available types of instruments, and we will discuss also what kind of information can be obtained with these instruments.
It is important to understand that a fluorescence value by itself has no meaning. A well-defined reference state for the photosynthetic sample measured is needed to allow an appropriate interpretation of the data. Processes that relax following illumination will be discussed here as well as the time needed to reach the dark-adapted state, which is an important reference state.
A widely read introductory paper on the use of Chl a fluorescence is by Maxwell and Johnson, and two more recent papers treating the application of Chl a fluorescence techniques are by Logan et al. and Murchie and Lawson. These papers focus on the analysis of what is called the steady state: the stable photosynthetic activity after 5–10 min of illumination at a chosen light intensity. Here, our focus is broader, considering a wider range of fluorescence techniques. We make the point that interpretation of fluorescence data can be improved making use, at the same time, of different classes of fluorescence techniques, as well as by the use of complementary techniques such as gas exchange and 820 nm transmission/absorption measurements. We also emphasize that there are still controversies with respect to the interpretation of Chl a fluorescence data.
The educational review is meant to be a starting point for researchers interested in further exploiting Chl a fluorescence measurements to understand photosynthetic systems. Some questions arise are trivial, e.g.,
Question 1: should the instrument be called fluorimeter or fluorometer?
Both versions are allowed, the former being British-English and the latter American-English.
Answers to other questions may make the difference between a successful and a failed experiment.
Question 2. Which types of instruments are available for fluorescence measurements?
For a rough classification of fluorescence instruments used to probe electron transfer reactions involving photosystem II (PSII) and/or photosystem I (PSI), three major classes can be distinguished (see Fig. 1 for an illustration of this classification and see Question 33 for a discussion of fast repetition rate (FRR) measurements and equipment). Instruments based on short light flashes (few μs or less). With such instruments, information on the electron transfer reactions within PSII can be obtained: re-oxidation kinetics of Q A− via forward electron transfer to Q B or recombination with the donor side of PSII (see Fig. 2). Instruments based on a saturating pulse (few hundred ms strong light). With such instruments, information on the photosynthetic electron transport chain (ETC) can be obtained: reduction kinetics of the ETC, PSII antenna size, relative content of ETC components like PSI (see Fig. 3). Instruments designed to study the steady state (relatively stable photosynthetic activity after 5–10 min of illumination). With such instruments, light-induced regulatory mechanisms, interaction between ETC, Calvin–Benson cycle, stomatal opening, and photorespiration (the process initiated when the enzyme Rubisco reacts with O2 instead of CO2) are studied (see Fig. 4).
Instruments based on short light flashes (few μs or less). With such instruments, information on the electron transfer reactions within PSII can be obtained: re-oxidation kinetics of Q A− via forward electron transfer to Q B or recombination with the donor side of PSII (see Fig. 2).
Instruments based on a saturating pulse (few hundred ms strong light). With such instruments, information on the photosynthetic electron transport chain (ETC) can be obtained: reduction kinetics of the ETC, PSII antenna size, relative content of ETC components like PSI (see Fig. 3).
Instruments designed to study the steady state (relatively stable photosynthetic activity after 5–10 min of illumination). With such instruments, light-induced regulatory mechanisms, interaction between ETC, Calvin–Benson cycle, stomatal opening, and photorespiration (the process initiated when the enzyme Rubisco reacts with O2 instead of CO2) are studied (see Fig. 4).
Flash fluorescence measurements
Figure 2 shows an example of a typical flash fluorescence experiment. These measurements are based on the concept of a single turnover flash (STF). An STF has to meet two requirements: (1) The intensity of a STF must be high enough to excite the antennae of all PSII reaction centers (RCs) followed by a charge separation in all PSII RCs leading to a reduction of essentially all Q A; (2) A STF must be short enough to induce only one charge separation in each PSII RC. In practice, this situation is never completely reached, and either misses or double hits are induced in a small fraction of PSII RCs (see e.g., Kok et al.; Shinkarev ). The re-oxidation of Q A− can then be followed: in active RCs, most electrons will be transferred to Q B and following a second flash to Q B− (see Fig. 2). The first reaction has a half-time of 100–200 μs, and the second reaction has a half-time of 400–600 μs (reviewed by Petrouleas and Crofts ). If no PQ is bound to the Q B-site, the electron on Q A− has to wait, till a PQ molecule binds to the Q B-site, and this process can take a few ms (Crofts and Wraight ). In the case of inactive PSII centers, forward electron transfer cannot take place, and re-oxidation of Q A− occurs via a recombination reaction with the donor side of PSII (Lavergne; Chylla et al.; Lavergne and Leci; Schansker and Strasser ). These instruments can also be used to study the S-states (oxidation states S0, S1, S2, S3 and S4) of the oxygen evolving complex of PSII. A series of STFs induces period-4 oscillations in the F O-level as a function of the S-states (see Delosme; Delrieu; Ioannidis et al. for examples of such measurements).
To probe the oxidation of reduced Q A following a saturating flash, there are two possible approaches:The easiest method makes use of low-intensity modulated light, which excites only a small fraction of the PSII RCs per unit of time. Figure 2 shows an example of such a measurement. For control samples, in which re-oxidation of Q A− via forward electron transport can occur, this approach works well. However, when the sample is inhibited, e.g., by an electron transfer inhibitor such as DCMU (3-(3,4-dichlorophenyl)-1,1-dimethylurea), which displaces Q B from its binding site (Velthuys; Lavergne ), the low-intensity modulated light leads to the accumulation of a considerable population of Q A− complicating the analysis of the experiment, because re-oxidation of Q A− by recombination with the donor side is much slower than forward electron transport to Q B.The second method uses a combination of a STF followed by a probe flash that probes the redox state of Q A at the time of the probe flash (this is called a pump–probe experiment) (Mauzerall; Robinson and Crofts ). The intensity of the probe flash is much lower than that of the STF. In this case, the experiment is repeated many times and each time at a variable time t after the STF, a probe flash is given to probe the redox state of Q A. In this way, the re-oxidation kinetics are constructed point by point. The actinic light problem, described above for DCMU inhibited samples, does not exist in this case. On the other hand, identical samples do not exist, and therefore, the biological variability between samples will lead to experimental noise and the need for repetitions to obtain smooth kinetics. To make different phases in the re-oxidation kinetics visible, the use of a logarithmic time scale has been introduced (see e.g., Cser and Vass ). Commercial equipment to make this type of measurements is the superhead fluorometers (Photon Systems Instruments, Brno, Czech Republic), which can also be used to measure OJIP transients and saturating pulse protocols (see below).
The easiest method makes use of low-intensity modulated light, which excites only a small fraction of the PSII RCs per unit of time. Figure 2 shows an example of such a measurement. For control samples, in which re-oxidation of Q A− via forward electron transport can occur, this approach works well. However, when the sample is inhibited, e.g., by an electron transfer inhibitor such as DCMU (3-(3,4-dichlorophenyl)-1,1-dimethylurea), which displaces Q B from its binding site (Velthuys; Lavergne ), the low-intensity modulated light leads to the accumulation of a considerable population of Q A− complicating the analysis of the experiment, because re-oxidation of Q A− by recombination with the donor side is much slower than forward electron transport to Q B.
The second method uses a combination of a STF followed by a probe flash that probes the redox state of Q A at the time of the probe flash (this is called a pump–probe experiment) (Mauzerall; Robinson and Crofts ). The intensity of the probe flash is much lower than that of the STF. In this case, the experiment is repeated many times and each time at a variable time t after the STF, a probe flash is given to probe the redox state of Q A. In this way, the re-oxidation kinetics are constructed point by point. The actinic light problem, described above for DCMU inhibited samples, does not exist in this case. On the other hand, identical samples do not exist, and therefore, the biological variability between samples will lead to experimental noise and the need for repetitions to obtain smooth kinetics. To make different phases in the re-oxidation kinetics visible, the use of a logarithmic time scale has been introduced (see e.g., Cser and Vass ). Commercial equipment to make this type of measurements is the superhead fluorometers (Photon Systems Instruments, Brno, Czech Republic), which can also be used to measure OJIP transients and saturating pulse protocols (see below).
Complementary techniques for flash fluorescence measurements are thermoluminescence (TL) (reviewed by Vass and Govindjee; Misra et al.,; Ducruet and Vass ) and delayed fluorescence (DF) (recently reviewed by Goltsev et al. ) measurements that provide specific information on recombination reactions within PSII RCs.
Flash fluorescence measurements are frequently used to study PSII mutants (e.g., Etienne et al.; Nixon et al.; Cser and Vass ) and can also be used in the case of treatments that affect the function of PSII [e.g., stresses like heat stress (Yamasaki et al. )] or to probe the PQ redox state (Dannehl et al. ).
Saturating pulse or OJIP measurements
Upon a dark-to-light transition, the fluorescence intensity of a leaf or other photosynthetic samples increases from a low value (F O or O) via two intermediate steps (F J or J and F I or I) in 200–300 ms to a maximum value (F M or P) during the application of a saturating pulse of light (see Fig. 3a, b; Strasser and Govindjee; Strasser et al. ). The different fluorescence rise phases (OJ, JI and IP) can be related to different steps of the reduction of the ETC: OJ parallels the reduction of the acceptor side of PSII (Q A + Q B); JI parallels the reduction of the PQ-pool and IP parallels the reduction of the electron transport acceptors in and around PSI (Schansker et al. ). This means that OJIP transients give information on the state of the ETC. Although complex simulations of OJIP transients use a kinetic model based on the gradual reduction of the ETC (see e.g., Lazár; Zhu et al. ), it has been shown that the transients can also be approximated assuming that the transients consist of three kinetic components (Boisvert et al.; Vredenberg; Joly and Carpentier ) indicating that the rate limitations (exchange of PQ at the Q B-site of PSII and re-oxidation of PQH2 by cyt b6/f) quite effectively separate the three rise phases kinetically. The kinetics of the OJIP transient are, e.g., sensitive to the PQ redox state (Tóth et al. ) and PSI content (Oukarroum et al.; Ceppi et al. ). During the isolation of thylakoid membranes, the properties of the ETC are modified, and this is reflected by changes in the fluorescence kinetics. Attempts have been made (see e.g., Bukhov et al. ) to make the fluorescence induction kinetics of thylakoid membranes look more like those of leaves.
Using a pulse-probe approach, a first pulse reduces the ETC and a second probe pulse given at time t after the first pulse probes the redox state of the ETC. The analysis of the regeneration kinetics of the OJIP transient gives information on the rate of re-oxidation of Q A− by recombination with the donor side of PSII, the re-oxidation of the PQ-pool due to plastoquinol oxidase activity (see Question 17), and the rate of re-oxidation of the acceptor side of PSI in darkness (Schansker et al. ).
Complementary techniques for OJIP measurements are 820 nm absorbance/transmission measurements that probe the redox state of PSI (plastocyanin, P700 and ferredoxin) and DF measurements that give information on the occurrence of recombination reactions in PSII as a function of the redox state of the ETC. The interpretation of these measurements can also be improved by determining the chl a/b ratio and the chl content of the leaves/cells. OJIP measurements have been used widely to study the effects of stress (see Questions 19, 24, 26–28).
Steady state measurements
The steady state refers to the relatively stable photosynthetic activity that is obtained when leaves or other photosynthetic samples are illuminated at a chosen light intensity during approximately 5–10 min (or more). The Chl a fluorescence intensity in the steady state is affected both by the redox state of the ETC (and Q A in particular) and by changes in the fluorescence yield, i.e., a change in the probability that absorbed light is emitted as Chl a fluorescence. These yield changes not only can be due to the formation of the transthylakoid ΔpH (Krause et al. ) and xanthophyll cycle (XC) related changes (Bilger and Björkman ), antenna size changes—for example, due to state transitions, which are especially obvious for algae such as Chlamydomonas reinhardtii (see e.g., Iwai et al. )—or photoinhibition (see e.g., Björkman and Demmig; Van Wijk and Krause; Tyystjärvi and Aro ) but are also due to the activation of ferredoxin NADP+-reductase (FNR) on the acceptor side of PSI (Schansker et al., ). In the 1980s, an analysis was developed, called the quenching analysis (see Question 15 for a more detailed discussion of the quenching analysis) that can distinguish between redox changes (photochemical quenching) and fluorescence yield changes. A fluorescence yield change occurs when the rate constant for either fluorescence or heat emission changes. If this leads to a smaller F M value (and in many cases smaller F O value), this is called non-photochemical quenching. Figure 4 gives an example of such a protocol. Just as in the case of the flash fluorescence measurements (see above), the fluorescence intensity is probed using low-intensity modulated light. The steady state is induced using continuous actinic light of a chosen intensity, and in addition every 100 or 200 s (this can be variable time interval), a saturating pulse (comparable to an OJIP transient) is given to reduce the ETC and all Q A. On turning off the actinic light, relaxation of the induced non-photochemical quenching can be followed using saturating light pulses to probe changes in the F M level. In general, three relaxation phases are observed (Demmig and Winter; Horton and Hague ): the qE which relaxes within 100–200 s as a consequence of the dissipation of the transmembrane ΔpH, the qT, whose relaxation is complete within 15 min and the qI which covers all processes that need more than 15 min to recover. As will be discussed later in detail (see Question 15) the qT and qI are less well defined. It is worth mentioning here that by measuring Chl a fluorescence induced by the saturating pulses with a higher time resolution (i.e., measuring OJIPs), it is possible to obtain more information on the character of the qT and qI phases (Schansker et al. ). The relaxation of the different non-photochemical quenching phases can be treated as the sum of three exponentials (see e.g., Walters and Horton; Roháček; and Question 15).
Obtaining the ‘maximum’ F M′ value is not a trivial issue. Markgraf and Berry and Earl and Ennahli observed that in the steady state, high light intensities are needed to induce the maximum F M′ value. Earl and Ennahli observed that more than 7,500 µmol photons m−2 s−1 (the maximum intensity of their light source) were needed to reach the maximum F M′ value of their maize leaves and that at higher actinic light intensities, more light was needed to saturate F M′. Schansker et al. observed the same actinic light intensity dependence measuring both fluorescence and 820 nm transmission and suggested that the ferredoxin/thioredoxin system that is thought to continuously adjust the activity of several Calvin–Benson cycle enzymes (see Question 6), is responsible for the actinic light intensity dependence. Earl and Ennahli proposed an extrapolation method based on the measurement of F M′ at two light intensities to obtain the true F M′ value. Loriaux et al. studied the same light intensity dependence of F M′ and proposed the use of a single multiphase flash lasting approximately 1 s to determine the maximum F M′ value. This flash consists of two high light intensity phases separated by a short interval at a lower light intensity during which the fluorescence intensity decreases. The second high light intensity phase of this protocol has a higher light intensity than the first phase (see also Harbinson for a commentary on this paper).
Complementary techniques for this type of fluorescence measurement are gas exchange measurements (to probe Calvin–Benson cycle activity, stomatal opening, CO2 conductance) and 820 nm absorbance/transmission measurements.
77 K fluorescence spectra
Low temperature (77 K) fluorescence measurements represent another technique to obtain information on the photosystems. At room temperature, variable fluorescence is emitted nearly exclusively by PSII. Byrdin et al. detected only a small difference in the quenching efficiencies of P700 and P700+ at room temperature. This is supported by the observation that inhibiting PSII by DCMU (Tóth et al. ) or cyt b6/f by DBMIB (Schansker et al. ) does not affect F M despite a big difference in the redox state of P700 in the absence and presence of inhibitors. However, variable fluorescence emitted by PSI can be induced on lowering the temperature to 77 K. Although measurements of light-induced fluorescence changes can be made at 77 K, in most cases, the fluorescence emission spectrum (600–800 nm) is measured. This type of measurement is used to obtain information on the PSII and PSI antennae. A common application of 77 K measurements is the detection of the occurrence of state transitions (e.g., Bellafiore et al.; Papageorgiou and Govindjee; Drop et al. ), where changes in the relative amplitudes of the PSII and PSI bands are indicators for this process. Figure 5 gives an example of a measured 77 K spectrum. Emission bands at 685 and 695 nm are related to the antenna of PSII, and peaks around 730 nm are related to the antenna of PSI (Govindjee; Špunda et al.; Srivastava et al. ).
Complementary techniques are ultrafast femto- or picosecond absorbance or fluorescence measurements that give information on energy transfer within the antenna (e.g., Gilmore et al.; Richter et al. ) but which are beyond the scope of this educational review.
Fast fluorescence techniques (ns, ps, fs time range)
As noted in the previous paragraph, fast fluorescence (and absorption) techniques, which probe energy transfer between chlorophylls or between carotenoids and chlorophylls in the photosynthetic antennae and the charge separation processes in the RCs of PSII and PSI will not be discussed in this paper. See e.g., Holzwarth and Berera et al. for introductory reviews on the application of these methods.
Question 3. What is the effect of wavelengths at which the fluorescence is measured on the character of the fluorescence signal?
Most commercial instruments measure Chl a fluorescence at wavelengths longer than 700 nm. At room temperature, at wavelengths longer than 700 nm, PSI becomes an important source of fluorescence emission. As shown by Genty et al. and Pfündel in C3 plants, about 30 % of the F O emission is due to PSI fluorescence, and in C4 plants, this percentage is even higher (Pfündel ). This causes, e.g., a systematic underestimation of the F V′/F M′ value, which is used as a measure of the maximum quantum yield of PSII. Detecting Chl a fluorescence emission at wavelengths below 700 nm can considerably reduce this problem. However, in measuring equipment such as photosynthetic efficiency analyser (PEA) and HandyPEA instruments (Hansatech Instruments Ltd, UK) which use red LEDs with an emission peak around 650 nm, this would have led to an overlap between the actinic wavelengths and the detecting wavelengths. With the introduction of (strong) LEDs emitting at shorter wavelengths, e.g., in the blue (see e.g., Nedbal et al. ), it is now technically possible to avoid this overlap and to detect fluorescence below 700 nm. Interference of PSI fluorescence at wavelengths longer than 700 nm should be taken into account especially when measuring fluorescence parameters in the light-adapted state. Non-photochemical quenching induced in the light quenches the variable fluorescence (F M–F O) to a larger extent than F O fluorescence. This makes the underestimation of the true F V′/F M′ value light intensity dependent as well, since a higher light intensity induces more non-photochemical quenching.
Question 4. Which part of the leaf is probed and analyzed by a fluorescence measurement?
The leaf is optically complex. In a dorsiventral leaf, the palisade parenchyma cells have been shown to act as light guides, keeping the light more or less focused (Vogelmann and Martin; Vogelmann et al. ). The lobed cells of the spongy mesophyll and the spaces that surround these cells, on the other hand, disperse the light (Vogelmann and Martin ). At the same time, there is a strong light gradient within the leaf (Vogelmann, ). This means that the light intensity decreases rapidly as light penetrates into the leaf. As a consequence, illuminating and probing Chl a fluorescence emission on the adaxial surface of the leaf, chloroplasts located deep in the leaf will be excited by a much lower photon flux density than those located close to the adaxial side of the leaf (Terashima and Saeki; Fukshansky and Martinez von Remisowsky ). At the same time, the spectral distribution of the light changes as well: as light penetrates the mesophyll, the relative contribution of green and far-red (FR) light progressively increases, because the absorption of these wavelengths by the leaf is less efficient (Sun et al.; Rappaport et al. ). The chloroplasts located deeper in the leaf, i.e., those of the spongy tissue, acclimate to these lower, FR-enriched light intensities by increasing the antenna size of PSII, reducing the number of RCs, and decreasing the PSI/PSII ratio (Terashima et al.; Evans; Fey et al.; Pantaleoni et al. ). Since the emitted fluorescence is a linear function of the light intensity (Vogelmann and Evans; cf. Schansker et al. ), chloroplasts located deeper in the leaf will contribute to a lesser extent to the detected fluorescence signal. In practice, fluorescence measurements will probe mainly chloroplasts in the palisade parenchyma cells (Vogelmann and Evans ). The assumption that not all chloroplasts are assayed is supported by the observation that a fivefold decrease in the chlorophyll content of the leaf does not affect the detected F O and F M values (Dinç et al. ). In fact, since the total amount of fluorescence emitted by the leaf does not change, it suggests that the light beam probes deeper in the leaf as more chlorophyll is lost. The optical properties of the leaf also mean that measurements made on the abaxial (bottom) side of the leaf have characteristics that differ considerably from those made on the adaxial (top) side of the leaf (Schreiber et al. ). Oxygen and CO2 assimilation measurements on the other hand assay the whole leaf, and this may lead to deviations when comparing, for example, measurements of the oxygen evolving activity with fluorescence measurements (Björkman and Demmig; Tyystjärvi and Aro ).
Given the gradient of photosynthetic properties that exists within the leaf (Terashima et al.; Evans ), the photosynthetic response of a leaf depends on the wavelength composition of the exciting light. Deeper penetrating green light probes more low light acclimated chloroplasts located in the lower cell layers than blue light that is strongly absorbed by the leaf and mainly probes chloroplasts close to the adaxial side of the leaf.
Question 5. How to dark-adapt leaves?
For the interpretation of Chl a fluorescence measurements, it is important that the state of the photosynthetic apparatus at the beginning of the measurement is well defined. The dark-adapted state of the leaf is a well-defined state of the photosynthetic apparatus and, therefore, for most experiments, photosynthetic samples are first dark adapted.
There are four main methods to achieve dark adaptation in leaves:In the case of an intact plant, a leaf can be put into a leaf clip shielding it from ambient light. However, if the ambient light intensity is high, and the leaf is not entirely flat, there is a chance that some stray light reaches the shielded area.Detached leaves can be kept for a while between wet filter paper in darkness and subsequently measured in the laboratory. Detachment of leaves has consequences for the physiological state of the leaf: it causes, for example, a closure of the stomata (Raschke ). See Potvin and Weng et al. for a comparison of the properties of attached and detached leaves and Kato et al. for a discussion of the differences between leaves and leaf disks.Under laboratory conditions, measurements can be made in the dark or in a dimly lit room under conditions that induce very little photosynthetic activity. Traditionally, low-intensity green light has been used as a kind of safe light (see Sun et al. for a discussion of this point) although we note that leaves can still absorb and use most of the green light for photosynthesis (cf. Sun et al.; Vogelmann and Evans; Rappaport et al. ).Loss of time for dark adaptation can be avoided when the measurements are made directly in the field at night (no need for leaf clips). In this case, the leaves are allowed to dark adapt for many hours, and the results of such measurements differ from measurements on leaves following a relatively short dark-adaptation period during the day.
In the case of an intact plant, a leaf can be put into a leaf clip shielding it from ambient light. However, if the ambient light intensity is high, and the leaf is not entirely flat, there is a chance that some stray light reaches the shielded area.
Detached leaves can be kept for a while between wet filter paper in darkness and subsequently measured in the laboratory. Detachment of leaves has consequences for the physiological state of the leaf: it causes, for example, a closure of the stomata (Raschke ). See Potvin and Weng et al. for a comparison of the properties of attached and detached leaves and Kato et al. for a discussion of the differences between leaves and leaf disks.
Under laboratory conditions, measurements can be made in the dark or in a dimly lit room under conditions that induce very little photosynthetic activity. Traditionally, low-intensity green light has been used as a kind of safe light (see Sun et al. for a discussion of this point) although we note that leaves can still absorb and use most of the green light for photosynthesis (cf. Sun et al.; Vogelmann and Evans; Rappaport et al. ).
Loss of time for dark adaptation can be avoided when the measurements are made directly in the field at night (no need for leaf clips). In this case, the leaves are allowed to dark adapt for many hours, and the results of such measurements differ from measurements on leaves following a relatively short dark-adaptation period during the day.
Question 6. What is a “good” dark-adaptation time?
Dark adaptation of samples that will be used for Chl a fluorescence measurements, is often associated with the re-oxidation of Q A−. However, dark adaptation is a considerably more complicated process, and there are more factors that can affect a subsequent fluorescence measurement.
In dark-adapted leaves, several enzymes are inactivated to prevent wasteful reactions. Examples of such enzymes include Rubisco (e.g., Streusand and Portis ); four other thioredoxin-dependent enzymes: d-fructose1,6-bisphosphatase, phosphoribulokinase, and sedoheptulose-1,7-bisphosphatase (Buchanan; Scheibe ) and ATP synthase (Stumpp et al. ); and FNR (Carillo et al.; Satoh ). These enzymes are active in the light, and during a light-to-dark transition, they gradually become inactive again. The half-time of inactivation of Rubisco under in vivo conditions is 2–4 min (Stitt et al.; Laisk and Oja ). Inactivation of ATP synthase and the three other Calvin–Benson cycle enzymes is under control of the thioredoxin system (Scheibe ), and their inactivation depends on the re-oxidation of stromal components such as ferredoxin and NADPH. FNR inactivation varies depending on the species: pea leaves need ~15 min for full inactivation (Schansker et al. ), whereas in a Pinus species, an hour is needed (Schansker et al. ). Once inactivated, all of these enzymes must first be activated again before steady state photosynthesis is induced, and this affects the fluorescence induction kinetics (see Papageorgiou et al.; Papageorgiou and Govindjee for an in-depth discussion of the fluorescence kinetics beyond P or F M in a variety of photosynthetic organisms). In addition, active FNR (i.e., an activated acceptor side of PSI) has an effect on the IP phase of the OJIP transients and on the amplitude of the F M that can be reached by a strong pulse of light (Schansker et al. ). In most fluorescence studies, many are not interested in the processes mentioned above, and in that case, it is best to make the dark-adaptation time long enough to allow at least FNR to become inactive again (a marker for this is a regeneration of the fluorescence IP phase and in addition a regeneration of 820 nm re-reduction phase paralleling the IP phase, see Schansker et al., ).
As mentioned in Question 2 Sect. 3, several regulatory and stress-related processes that affect the fluorescence yield (quench F M) are induced in the light. Following a light-to-dark transition, i.e., on turning off the light, these processes are reversed. State transitions (the transfer of a part of the antenna system among PSII and PSI) and XC related processes may take a considerable amount of time to reverse (Fork and Satoh; Ruban and Horton ) and the recovery of a plant from photoinhibition takes hours (Havaux; Long et al. ).
An answer to the question as to what a good dark-adaptation time is, depends on the information we want to obtain. If the aim is the study of the regulatory and photoinhibition-related processes, a dark-adaptation time of 15 min that allows FNR (at least in plants like pea) to become inactive again would be sufficient. If someone is interested in long term adaptation responses of a leaf or other photosynthetic organism to a treatment, much longer dark-adaption times that allow also the regulatory processes and processes like photoinhibition to recover may be considered (see also the next question).
Question 7. How to obtain the best reference FO and FM values for the quenching analysis?
In field experiments, predawn measurements are often used to obtain reference F O and F M values for measurements made during the day (Logan et al.; Maxwell and Johnson; Demmig-Adams et al. ). Under these conditions, NPQ is assumed to be completely relaxed and therefore zero, and the photoinhibition induced during the previous day is expected to have been reversed (Flexas et al.; Logan et al.; Demmig-Adams et al. ). However, in some cases, chronic photoinhibition occurs, which can be easily detected by lowered predawn F V/F M values (Osmond and Grace; for a review see Demmig-Adams et al. ). We note that the absence of light during recovery experiments may prevent a full repair of photoinhibitory (Greer et al. ) and heat stress damage (Tóth et al. ). Light is needed for the synthesis of ATP, which is needed for the synthesis of the D1 protein (Kuroda et al. ). Edhofer et al. have reported that light is needed for translation elongation of the D1 protein; these are processes that are part of the PSII repair cycle following damage to PSII (recently reviewed by Nixon et al. ). Low-intensity actinic light generates the ATP needed for the PSII repair cycle, and at the same time, it does not induce additional photoinhibition and is thereby more effective than a complete dark recovery (see e.g., Elsheery et al. ).
Question 8. What can go wrong during a fluorescence measurement on leaves? Technical issues
To dark-adapt leaves in the field, leaf clips have been developed. They cover the area of the leaf to be measured. The measuring head of, for example, a HandyPEA can be connected to a leaf clip, after which the clip can be opened, and the measurement made. Since such measurements are normally evaluated afterward, it should be kept in mind that unopened or partially opened leaf clips are a common reason for transients showing no or little fluorescence rise. A smooth leaf can also lead to problems, since the clip may shift while attaching the measuring head, and in that case, a non-dark-adapted part of the leaf will be measured. If the leaf is not flat, some stray light may enter the leaf clip via the spaces left between the leaf clip and the leaf surface. Especially on a bright day, this may prevent a full dark adaptation of the covered leaf area. The same problems can occur with pulse amplitude modulated (PAM) type instruments developed for field applications, which use leaf clips to allow dark adaptation.
When working with a PAM instrument, the measuring light intensity must be chosen in such a way that the F M stays within the measuring window. If the measured signal is too strong, then the highest values will be cut off. For example, as a rule of thumb the fluorescence intensity induced by the measuring light (associated with F O) should be approximately 10 % of the total scale. In any case, absolute values and their limits depend on the manufacturer, and its instructions should be carefully read before starting any measurements. Further, the distance between the leaf and the fiber optics has to be adjusted; it is usually set between 1 and 1.5 cm. Background fluorescence signals from the environment must be suppressed by zeroing the signal in the absence of a leaf sample.
Using direct fluorescence equipment like the HandyPEA, there is also a risk that the emitted fluorescence intensity causes an overload of the detector. It is therefore important to check if, at a given gain and excitation light intensity, the measured fluorescence kinetics remain below the maximum measurable fluorescence intensity. If the emitted fluorescence intensity is too strong, then the top part of the transient will be cut off, and in that case, the gain has to be reduced.
Question 9. Why was it so difficult to determine the FO before ~1985?
It may be hard to imagine nowadays, but the determination of a correct FO value was a major problem for researchers using Chl a fluorescence up to the mid-1980s (see Kalaji et al., for a historical overview of instrument development). The shutters used at the time had a full opening time of anywhere between 0.8 ms (e.g., Neubauer and Schreiber ) and 2 ms. At high light intensities, the J-step is reached after ~0.8–2 ms of illumination. To minimize the effect of the shutter opening time, in many studies, low-intensity light was used to slow down the fluorescence induction kinetics. In the 1980s, two fundamentally different solutions for the shutter problem were introduced in the form of modulated systems (Schreiber et al. ) and PEA-type instruments (Strasser and Govindjee ). These two measuring concepts are explained and compared in Questions 10 and 11.
Question 10. What is the principle of modulated fluorescence measurements?
Modulated systems, pulse amplitude modulated fluorometers, (PAM) use a trick to separate the effect of the actinic light that drives photosynthesis and the low-intensity measuring light that is used to probe the state of the photosynthetic system on the measured fluorescence intensity (see also Question 2 Sect. 3). A so-called lock in amplifier only registers the fluorescence changes induced by the modulated measuring light and ignores the fluorescence changes induced by the continuous actinic light. This way the low-intensity measuring light can be used to measure both the F O (induced by the measuring light itself) and F M (induced by a strong light pulse) values (Schreiber et al. ). The effective light intensity of modulated light depends on the pulse frequency. In the case of a modern PAM instrument, the modulated measuring light consists of 1–3 µs flashes of red or white light, and flash frequencies between 100 and 20,000 Hz can be chosen. At the lowest frequency, the effective photosynthetic photon flux density is <0.2 µmol photons m−2 s−1; an intensity that is 200 times higher when the highest frequency is chosen. The choice of a low frequency gives not only a very small actinic effect (= measuring-light-induced F V) but also a relatively poor signal-to-noise ratio. A high frequency not only is considerably more actinic but gives also a much better signal-to-noise ratio. The actinic effect of the measuring light becomes especially visible (and problematic) if PSII electron transfer inhibitors such as DCMU are being used (see Question 2 Sect. 1). Compared to PEA-type instruments an advantage of the modulated fluorimeters is that the measured fluorescence yield is independent of the intensity of both the actinic light and light of the saturating pulse (Schreiber et al. ). In the case of PEA-type instruments, the measured fluorescence intensity is a linear function of the actinic light intensity used, and as a consequence, the measured fluorescence intensities must be normalized first (e.g., divided by the light intensity) before measurements made at different light intensities can be compared (see e.g., Schansker et al. ).
Question 11. What is the principle of direct fluorescence measurements?
In the so-called direct fluorescence instruments-i.e., instruments in which the actinic light that drives photosynthesis is also used as measuring light-the F O problem is solved by using strong light emitting diodes (LEDs): light sources that can be switched on/off very quickly (Strasser and Govindjee ). In modern equipment, a stable light intensity emitted by the LEDs is reached in less than 10 μs. Initially, only red (650 nm) LEDs were available for this type of measurement but now colors like other orange (discussed by Oxborough ), green (Rappaport et al. ), and blue (Nedbal et al. ) or a mix of LEDs of different colors (Schreiber ) are also available. In the original PEA instrument, the response time of the LEDs was still in the order of the 40–50 μs (e.g., Strasser et al. ) necessitating the use of extrapolation to estimate the F O value; in the current instruments, a response time of 10–20 μs is good enough for an accurate determination of the F O value for light intensities below ~10,000 μmol photons m−2 s−1 (cf. Schansker et al. ). The absence of a measuring light source means that between pulses, there is true darkness. As a consequence, the F O can be determined more accurately than in the case of a modulated system (see Schansker and Strasser for a discussion on the effects of very low light intensities on the F O value). The absence of measuring light is particularly advantageous when the samples to be analyzed have been inhibited with electron transfer inhibitor such as DCMU. Another important difference between PEA instruments and modulated PAM instruments is the data sampling strategy. In PEA instruments, the data sampling is non-linear. In HandyPEA instruments, during the first 300 μs of illumination one measuring point is collected every 10 μs; between 300 μs and 3 ms one point per 100 μs, between 3 and 30 ms one point per ms, and between 30 and 300 ms one point per 10 ms. In this way, an OJIP transient measured at a high time resolution is defined by approximately 120 measuring points. In the case of a PAM instrument, a measurement with the same initial time resolution would yield at least 20,000 measuring points (for 200 ms). This makes the HandyPEA files much easier to handle when analyzing them using spreadsheet programs like Microsoft Excel.
Question 12. Why use a logarithmic timescale to visualize fluorescence transient measurements?
As described above, PEA instruments allow a shutter-less measurement of OJIP transients. However, PEA instruments make use of a second innovation and that is the use of a logarithmic timescale to visualize the measurements of the OJIP fluorescence rise (Strasser and Govindjee ). Bannister and Rice had already used this idea more than 20 years earlier, but at that time, it was not picked up by others. The logarithmic timescale was later exploited by researchers measuring fluorescence relaxation following a STF, as well (see Question 2 Sect. 1; e.g., Cser and Vass ). The logarithmic time scale distorts the time dependence somewhat but, at the same time, allows the visualization of considerably more kinetic features than is possible on a linear time scale. This additional kinetic detail makes it much easier to detect changes in the fluorescence kinetics. Fluorescence measurements shown on a linear timescale are always dominated by the slower changes (see Fig. 3a). A logarithmic timescale turns exponential rise phases into sigmoidal rise phases, and we must keep in mind that the sigmoidicity of the fluorescence rise cannot be derived on the basis of fluorescence transients visualized on a logarithmic timescale.
Question 13. Direct or modulated fluorescence?
It is possible to measure OJIP transients using a modulated system (Schreiber; Neubauer and Schreiber; Schreiber and Neubauer ), and at the same time, it is possible to make a quenching analysis (see Questions 2.3 and 15) using a PEA-type instrument (Schansker et al. ). However, modulated instruments are much better suited for a quenching analysis, and PEA-type instruments are the instruments of choice for a study of the OJIP kinetics. Thus, we recommend that both must be used to get a complete picture.
Question 14. What kind of additional information can be obtained using fluorescence imaging?
All the instruments, discussed thus far, integrate the signal of the measured area. Fluorescence imaging permits the study of spatial heterogeneities in the fluorescence emission intensity within cells, leaves, or whole plants; heterogeneities caused by a range of internal plant factors (Gorbe and Calatayud ). It can also be used to average and analyze the fluorescence signal from much larger leaf areas than classical methods would allow, and at the same time, it allows the simultaneous measurement/screening of many samples/mutants in, for example, a microwell plate or of colonies grown on a Petri dish (see e.g., Niyogi et al.; Serôdio et al. ) or all the leaves of an rosette of Arabidopsis. There are several commercial imaging instruments on the market. It is a technique whose development has kept pace with improvements in LED technology. For reliable imaging measurements, it is critical that the whole sample area be illuminated homogeneously. Several introductory texts and reviews have been published on fluorescence imaging (e.g., Buschmann et al.; Oxborough; Lenk et al.; Scholes and Rolfe ). Since it was not possible to image F O′ with the imaging systems available in the late 1990s, Oxborough and Baker derived an equation to estimate it:
This equation allows the calculation of the parameters qP [=(F M′ − F S)/(F M′ − F O′)] and F V′/F M′. The challenge using fluorescence imaging is to process all the data collected in a scientifically meaningful way. Meyer and Genty analyzed their data making frequency distributions of parameters of interest; we recommend that this method is considered for future experiments.
Imaging can be used, e.g., to assess the dynamics and heterogeneous behavior of stomatal opening/closure over a leaf, a phenomenon also called stomatal patchiness. A palette of false colors is used to cover the range of fluorescence intensities (normalized between 0 and 1), assigning a color to each pixel of the image (Gorbe and Calatayud ). Based on the image, different areas of the leaf can be chosen, the associated fluorescence data averaged, fluorescence parameters can be calculated, and subsequently, the photosynthetic properties of the chosen area can be studied.
Using fluorescence imaging, it is easy to detect photosynthetic heterogeneities in a leaf (Meyer and Genty ) and to follow how any stress affects the leaf in spatial terms. In a popular early experiment, the imaging technique was used to show the gradual infiltration of PSII inhibiting herbicides in the leaf (e.g., Daley et al.; Lichtenthaler et al.; Chaerle et al. ) or the effect of reactive oxygen species (ROS)-inducing herbicides (e.g., Hideg and Schreiber ). Spatial heterogeneities that have been studied using fluorescence imaging include heterogeneities occurring during the following processes: induction of photosynthesis (Genty and Meyer; Daley et al. ), the onset of senescence (Wingler et al. ), chilling (Hogewoning and Harbinson ), the response to drought (Woo et al. ), nutrient stress (Landi et al. ), ozone stress (Gielen et al.; Guidi et al. ), wounding (Quilliam et al. ), and during infection with viruses (Balachandran et al. ) or fungi (Guidi et al. ). Several studies, using imaging to study Chl a fluorescence parameters under various conditions (high/low ambient CO2 concentration, high/low light intensity, etc.), have yielded information on the relationship between leaf structure and organization on the one hand and the response to stress conditions on the other (Baker; Roháček et al.; Guidi and Degl’Innocenti; Gorbe and Calatayud ).
Serôdio et al. have introduced, a new application of fluorescence-imaging systems, which allows the rapid generation of light-response curves (see Question 18) simultaneously illuminating replicates of samples using spatially separated beams of actinic light of different intensities.
Question 15. What kind of information can be obtained using the quenching analysis (see Question 2)?
In leaves exposed to a certain irradiance, the fluorescence intensity is affected by changes both in the redox state of the ETC (particularly the redox state of Q A) and in the fluorescence yield due to light-induced changes in the properties of the PSII antenna. A method called the quenching analysis was developed to separate these two types of process. In most cases, the quenching analysis is used to describe the steady state, i.e., the stable photosynthetic activity, which is usually reached after approximately 5–10 min of illumination at a chosen actinic light intensity.
A protocol was developed (Schreiber et al.; Fig. 4) based among others on the work of Bradbury and Baker in which the measurements are initiated by switching on the measuring light to determine the F O value of a dark-adapted sample. A saturating light pulse is then applied to determine the F M. The measurement is continued switching on an actinic light source to induce photosynthesis, until the fluorescence emission stabilizes at a level called F S. The F M′ is then determined by applying another strong pulse of light followed some time later (e.g., 10 s) by turning off the actinic light. Turning off, the actinic light will cause a quick, partial, re-oxidation of the photosynthetic ETC. Within the first 100 ms of darkness, the PQ-pool will be largely re-oxidized by forward electron transport toward PC+ and P700+, and a value close to F O′ can be measured. The F O′ level subsequently increases again due to non-photochemical reduction of the PQ-pool by NADPH and possibly Fdred (Mano et al.; Gotoh et al.; Guidi and Degl’Innocenti ). This so-called “F O′ rise” can be almost completely suppressed by a short pulse of FR light (e.g., of 1 s duration) following the turning off of the actinic light. The increase of the fluorescence intensity from F S to F M′ is related to a change in the redox state of the ETC, whereas the difference between F M′ and the dark-adapted F M is then a measure of the fluorescence yield change, which in the case of qE is associated with increased heat dissipation. In quenching analysis terminology, this approach splits the fluorescence changes into a photochemical quenching (redox related) and a non-photochemical quenching (fluorescence yield related) part. On turning off the actinic light, the relaxation of the non-photochemical quenching, i.e., the increase of F M′ to F M, can be followed and several contributing processes can be resolved (Walters and Horton; Roháček ). Schreiber et al. introduced the parameter qN = 1 − F V′/F V to quantify changes in the non-photochemical quenching. The parameter qN can range between 0 and 1, and for its calculation, the F O′ value is needed. In 1990, Bilger and Björkman introduced the parameter NPQ = F M/F M′ − 1 which has as advantages over the parameter qN that its range is not restricted (see Question 21), and in addition, it is not necessary to know the F O′ value. However, Holzwarth et al. evaluating the parameter NPQ, concluded that in this treatment of the fluorescence data, the relationship between the quenching parameter and the underlying processes becomes distorted, especially when the time dependence of NPQ is considered.
For the analysis of the relaxation kinetics of the parameter qN semi-logarithmic plots of Log(qN) versus time are made. This linearizes the slowest component. Using linear regression, the decay half-time and amplitude of this component can be determined. This component (an exponential function) can then be subtracted from the original data, and a new semi-logarithmic plot can be made of the remaining qN. The procedure can then be repeated (e.g., Walters and Horton; for a discussion of the theoretical basis of the resolution method, see Roháček ).
The least controversial of these kinetic processes is the process relaxing during the first 100–200 s of darkness, with a relaxation half-time of ~30 s. In quenching analysis terms, this is called the qE or high-energy quenching; it depends on a low lumen pH and is affected by the XC (reviewed by Horton et al.; Müller et al.; Gilmore; Krause and Jahns; Ballottari et al. ). However, the exact mechanism of the induction of the qE and the exact components involved in this process are still a hotly debated issue (e.g., Caffari et al.; Johnson et al.; Miloslavina et al. ). A set of mutants has been generated playing an important role in the study of the qE, in which different components and processes related to qE have been modified (Niyogi et al. ). The second process, the qT, with a half-time of 5–10 min has been assigned to state II to state I transitions (transfer of LHCII units from PSI to PSII) based on the observation that it was already induced at low light intensities (Demmig and Winter ) and on its possible sensitivity to the phosphatase inhibitor NaF (Horton and Hague ). Schansker et al. studying the kinetics of the saturating pulses showed that the main fluorescence change occurring in this time interval in pea leaves is the regeneration of the IP phase suggesting that the qT reflects the inactivation of the acceptor side of PSI (the inactivation of FNR). Other processes that have been associated with the qT are some slowly relaxing component(s) of qE (Lokstein et al.; Joliot and Finazzi ) and light-dependent movements of chloroplasts (Cazzaniga et al. ). In practice, there are several arguments making it doubtful that the qT is a reliable measure for state transitions. The slowest relaxation phase, the qI, which may last several hours can consist of several processes: photoinhibition of PSII and XC related changes (reviewed by Krause and Jahns ) and possibly also state II to state I transitions (Schansker et al. ) if a change in the JI amplitude is related to state transitions as suggested by Schreiber et al. for cyanobacteria. It should be noted that the rate with which these processes reverse in darkness is not necessarily the same in all photosynthetic organisms. For example, the regeneration of the IP phase parallels the qT phase in pea leaves (Schansker et al. ), and it is complete within 15 min, whereas the same process in needles of Pinus halepensis takes 1 h (Schansker et al. ).
Question 16. Why is far-red light used to determine the FO and FO′ values?
For leaves, it is reasonable to assume that under most conditions, nearly all PSII RCs are in the open state (Q A oxidized) following dark adaptation. However, the assumption is not true for heat-stressed leaves (Ducruet; Tóth et al. ) and leaves that show a high rate of chlororespiration. Chlororespiration refers to the non-photochemical reduction of the plastoquinone pool by reducing equivalents derived from Fdred or NADPH in the stroma (Bennoun ). Feild et al. showed a high chlororespiratory activity in light acclimated sunflower leaves following a light-to-dark transition leading to considerably higher F O′ values. This F O′ increase is due to a population of reduced Q A associated with a more reduced PQ pool. There is redox interaction between the PQ-pool and Q A leading to a redox-equilibrium (Diner ); for pea leaves, it was shown that a completely reduced PQ-pool (induced by anaerobiosis) is in equilibrium with reduced Q A in 20 % of the PSII RCs (Tóth et al. ).
To assure maximum oxidation of the PQ pool, the leaf can be pre-illuminated with FR light. For this purpose, FR light in the 720–735 nm range is normally used. FR light preferentially excites PSI and thereby causes an oxidation of the PQ pool. We note that FR light can induce charge separations in PSII (Pettai et al.; Schansker and Strasser ). Pettai et al. demonstrated that FR light at 740 nm still induces a low level of oxygen evolution even though the activity is three times less than that induced by FR light at 720 nm. In practice, FR light induces about 2.5 % of F V associated with Q B− in 50 % of the RCs (Schansker and Strasser ). However, this observation is only of importance for direct fluorescence measurements, since the effects induced by FR light are also induced by the measuring beam of a modulated fluorescence instrument.
A short FR pulse (~1 s, at ~720–735 nm) given to a light-adapted leaf has two main effects: (i) it re-oxidizes the PQ-pool within 100 ms and (ii) it suppresses the transient F O′ increase, which is normally observed following a light-to-dark transition (Mano et al.; Gotoh et al.; Guidi and Degl’Innocenti ). It is related to non-photochemical reduction of the PQ-pool by NADPH or Fdred; this process is mediated by an enzyme complex called NADPH dehydrogenase (NDH) (Burrows et al. ). The induction of the qE component of non-photochemical quenching leads to a quenching of the F M level and in many plant species to a quenching of the F O′ level as well (Bilger and Schreiber; Bilger and Björkman; Noctor et al. ). This qE quenching relaxes quickly in darkness. To determine the associated F O′ quenching accurately, the F O′ level must be determined immediately after turning off the actinic light. The non-photochemical reduction of the PQ-pool affects the F O′ level as well, and this may complicate an accurate determination of the extent of F O′ quenching. Since the non-photochemical reduction of the PQ-pool is a rather slow process peaking approx. 40 s after turning off the light (Burrows et al. ), and the maximum re-oxidation of the PQ-pool following lights off takes less than 100 ms (Ceppi ), the F O′ level can be determined quite accurately before the transient non-photochemical reduction of the PQ-pool sets in. However, using ~1 s of FR is the most straightforward approach to obtain an oxidized PQ pool.
Question 17. How can the NPQ index be calculated when NPQ is formed in the dark?
As noted in Question 16, a process called chlororespiration has been identified in higher plants (Bennoun,; Rumeau et al. ). Cyanobacteria, which are thought to be the ancestors of the chloroplast, lack mitochondria; instead they have a respiratory chain that shares the PQ-pool with the photosynthetic ETC (Vermaas; Schmetterer and Pils; Hart et al. ). It allows the creation of a pH gradient over the thylakoid membrane in the dark, and this gradient is utilized to synthesize ATP. In the dark, the respiratory activity in cyanobacteria is considerably higher than in higher plants. In fact, chlororespiration in higher plants is seen as a rudiment of the original respiratory chain. Also in green algae, the respiratory chain is still quite active (see Beardall et al. for a discussion of this topic). Another group of organisms that have been shown to have a high chlororespiratory activity are some microalgae, including diatoms (e.g., Caron et al. ). As a consequence, there is no complete relaxation of qE in the dark. XC activity in dark grown diatoms occurs as a result of the acidification of the thylakoid lumen due to this chlororespiratory activity (Jakob et al. ).
One effect of this high chlororespiratory activity in diatoms is that the F M level of dark-adapted diatoms is lower than the F M′ observed under low actinic light (Cruz et al. ). This means that it is not possible to apply the commonly used NPQ equation:since the calculated value would be negative [F M < F M′]. A practical solution for this problem is the determination of the light-response curve (see Question 18) and to replace F M by the maximum F M′ level measured (F M′max; Serôdio et al. ) in Eq (1):
So,
In this way, NPQ values will always be positive and approach a minimum value close to zero under conditions closely corresponding to a state with a very small transthylakoid proton gradient.
Question 18. Can the time that is needed for a complete quenching analysis be shortened?
To characterize the properties of parameters such as qP, Φ PSII [= (F M′ − F S′)/F M′] and NPQ, it is common practice to determine the light intensity dependence of these parameters (see e.g., Bilger and Björkman; Gray et al.; Verhoeven et al. ). The classical approach is to illuminate the leaf at each light intensity, until steady state is reached (see Questions 2.3 and 10). This process can be quite time-consuming, especially if the fluorescence quenching analysis is performed for field experiments.
To reduce the time needed for this type of measurement, a faster procedure was developed and called rapid light curves (RLCs) (White and Critchley; Ralph and Gademann ). RLCs can be used to study the physiological flexibility of the photochemistry in response to rapid changes in irradiation (Guarini and Moritz ). Such changes occur frequently in natural environments. An RLC is a plot of the electron transport rate (ETR: Φ PSII × PFD × 0.5 × leaf absorptivity coefficient) as a function of the actinic light intensity, which is applied for fixed short-time periods (e.g., 10 s or 1 min). Here, PFD stands for photon flux density, and here, it is assumed that the PSI:PSII ratio is 1:1. However, this is only a rough approximation and the real ratio will differ between samples (see Question 26). For this type of analysis, two criteria are important: (1) the samples must be dark adapted, and (2) photosynthesis must be induced [activation of the Calvin–Benson cycle enzymes that become inactive during incubation in darkness (see Question 6)] before the measurement sequence is started (White and Critchley ). Dark adaptation of the samples allows the determination of the reference F O and F M values needed for the calculation of qN and/or NPQ. If light-adapted samples are used for the experiments, for which reference F O and F M values are missing, then the effective quantum yield (Φ PSII) and ETR can still be calculated, but not the non-photochemical quenching parameters, nor qP. In other words, the best protocol consists of a dark acclimation of the sample, a weak modulated beam and a saturating pulse to determine the reference F O and F M, respectively, and then a pre-illumination with a moderate light intensity (approx. 50 % of the ambient light intensity applied for several minutes is appropriate for this purpose) after which the RLC protocol is applied (see Lichtenthaler et al. ).
Examples of RLCs (Fig. 6a) illustrate the importance of the duration of light intervals. In addition to differences in the values determined for individual light intensities, there is also a difference in the shape of the curves (Fig. 6b). Pre-illumination at moderate light intensities ensures faster induction. Thus, in pre-illuminated samples, a 30-s interval is sufficient to obtain appropriate values and shapes of the curves that are comparable to those measured with 2-min intervals (Fig. 6c).
RLCs have frequently been used in studies dealing with plant stress (reviewed in Brestic and Zivcak ). The value of the RLC approach increases if a second technique, e.g., 820 nm or gas exchange measurements, is applied simultaneously, or if fluorescence-imaging measurements are also made.
Question 19. What is the JIP test?
The idea that the fluorescence rise OJIP contains a lot of information on the photosynthetic system is already quite old. OJIP transients have been compared to a bar code for photosynthesis (Tyystjärvi et al. ) and extensive attempts to simulate OJIP transients have been made (see Lazár and Schansker for a review of these efforts). In 1991, Strasser and Govindjee published an article on the recording of the full fluorescence rise kinetics OJIP between 40 μs and 1 s using a PEA instrument (see Strasser et al. for details). Four years later, Strasser and Strasser proposed a method to analyze these OJIP transients that was centered on the J-step [observed after 2–3 ms of strong illumination and equivalent to the I 1 step of Schreiber], which they called the JIP test (see Fig. 7).
The theoretical basis of the JIP test has been described in detail by Strasser et al.. In the JIP test, OJIP transients are used to make a flux analysis, i.e., an analysis of the fate of photons absorbed by the PSII antennae (trapping, forward electron transport beyond Q A and dissipation as heat). In the JIP test, the J-step is taken as the border between single and multiple turnovers. If we define multiple turnovers here as events related to electron transport beyond PSII, then this claim still remains valid. The JIP test depends strongly on the assumption that the F O-to-F M rise reflects the reduction of Q A. The concept is internally consistent but the theoretical foundation of the interpretation of the parameters disappears the moment that this assumption turns out to be wrong (see Schansker et al., for a discussion of this point). An alternative approach to the interpretation of the OJIP transients is a classical physiological characterization of the various features of the fluorescence rise.
In the JIP test, it is assumed that the relative position of the J-step between F O and F M (i.e., V J, giving rise to the JIP-parameter 1 − V J or Ψ O) gives information on photosynthetic electron transport beyond Q A (e.g., Strasser et al., ). A physiological characterization of this feature, on the other hand, suggests that the parameter V J depends on the redox state of the PQ-pool in darkness (Tóth et al. ) and, under certain stress conditions, may also be affected by other factors, possibly the extent of stacking of the thylakoid membranes. In this case, electron transport beyond Q A means a slowdown of the re-oxidation of Q A− as the PQ-pool becomes more reduced, and fewer PQ molecules are bound to the Q B-site. Changes in Ψ O may certainly point to stress.
In the JIP test, the parameters F O and F M were suggested to be a measure for the absorption flux (i.e., the number of photons absorbed per unit of time) per cross section (Strasser et al., ). With respect to this interpretation, it may be noted that a characterization of the changes in the F O and F M levels as a function of the Chl content of leaves showed that they are nearly insensitive to changes in the leaf chlorophyll content as long as the antenna sizes of the RCs remain unaffected (Dinç et al. ). However, we note that this observation probably does not apply to dilute algal and thylakoid suspensions.
Malkin and Murata et al. showed that the complementary area between the fluorescence transient and F M in the presence of DCMU is proportional to the population of reduced Q A molecules. In the JIP test, this principle is extended to the situation in the absence of DCMU, where the area between the fluorescence transient and F J is assumed to equate one charge separation in all RCs, i.e., one electron transported, to which the total area above the OJIP transient can be normalized (see e.g., Strasser et al. ). Schansker et al. support and explain the relationship between the area above the OJIP transients (see Fig. 7) and the number of electrons that must be transported through the ETC before F M is reached.
In the JIP test, it is assumed that the slope taken between F O and F 150 μs is sensitive to a phenomenon called “connectivity,” i.e., the energy transfer between the antennae of several PSII RCs, whereas the slope taken between F O and F 300 μs is insensitive to connectivity (Strasser and Stirbet; and see Stirbet for a more in-depth discussion of connectivity in the absence of PSII inhibitors like DCMU).
The performance index [PI(ABS)] was introduced as an attempt to catch three different aspects of the photosynthetic activity of PSII in a single parameter (see Clark et al. for an early application of this parameter). PI(ABS) is the product of a parameter sensitive to the effective antenna size, a parameter based on the primary quantum yield of PSII and a parameter sensitive to changes in the relative position of F J. It is defined as:with V J = (F J − F O)/FM − F O). It is another JIP test parameter that has been shown to correlate with other stress parameters under a series of conditions (e.g., Clark et al.; Misra et al.,; Oukarroum et al. ). Physiological studies have further shown that the IP phase of the fluorescence rise is related to electron transport through PSI (Kautsky et al.; Munday and Govindjee; Schansker et al. ) and that the (relative) amplitude of the IP phase is linked to the PSI content of the leaf (Oukarroum et al.; Ceppi et al. ). The JIP test approach remains a good and fast way to screen a large number of samples (Kalaji et al., ). However, once parameters that correlate with certain features of a stress have been identified, it should not be blindly assumed that the interpretation of these parameters as given by the JIP test is correct (see also Stirbet and Govindjee for a discussion of this topic). In addition, it should be kept in mind that the JIP test depends strongly on normalizations which are very sensitive to the correctness of the determined F O and F M values. For example, in the case of heat stress, it is not easy to determine the F O and F M values correctly (see Tóth et al. ).
Question 20. What kind of values may one expect for particular fluorescence parameters?
The F V/F M values of plant species average approximately 0.83–0.84 in C3 plants under optimal conditions (Björkman and Demmig; Pfündel ) and 0.78 in C4 plants (Pfündel ). Somewhat higher values have been described in certain broadleaved species. Lower values, on the other hand, are common in algae and lichens (see Trissl and Wilhelm for a discussion of these values). Stress conditions (e.g., photoinhibition) can significantly reduce these values (e.g., Björkman and Demmig; Van Wijk and Krause; Tyystjärvi and Aro ).
Photochemical quenching qP, non-photochemical quenching defined as qN [= 1 − (F M′ − F O′)/(F M − F O)], and the PSII operating efficiency in the light (Φ PSII) can vary between 0 and 1 (see Question 14 for definitions of qP and Φ PSII). The theoretical range for the values of the non-photochemical quenching parameter NPQ [= F M/F M′ − 1] is from zero to infinity, but in most cases, it gives values between 0 and approximately 10. However, NPQ values higher than 10 have been reported in bryophytes from sun-exposed habitats (Marschall and Proctor; see Buschmann for a discussion and comparison of qN and NPQ). High Φ PSII values indicate that a large proportion of the light absorbed by the chlorophylls of the PSII antenna is converted into photochemical energy. At its upper limit, Φ PSII could reach a value of 1, which would mean that all absorbed energy is used for stable charge separations in PSIIs. From a practical point of view, this cannot be the case, due to the fundamental inefficiency of PSII (triplet formation, a small probability of fluorescence, and heat emission on each transfer of excitation energy between chlorophylls), and the contribution of fluorescence emitted by PSI has also an effect on the calculation (see Question 3). Therefore, Φ PSII can vary between zero and the F V/F M value, which in C3 plants is about 0.83–0.85, in C4 plants around 0.78 and in algae often below 0.7 (Pfündel; Trissl and Wilhelm ). qP values near zero indicate that most of the PSII RCs are closed, and their Q A is in the reduced state. Values near 1 indicate that Q A is in the oxidized state, and almost all of the PSII centers are open for photochemistry. The non-photochemical quenching coefficients qN and NPQ are assumed to be zero in the dark-adapted state, because then F V′ = F V and F M′ = F M. However, in some cases, positive values of these coefficients can also occur in darkness (see Question 17).
In higher plants, the induction kinetics of non-photochemical quenching triggered by high light usually have a typical time dependence: they increase during the first minute of illumination due to initiation of electron transport and ΔpH formation preceding the activation of ATP synthase (e.g., Nilkens et al. ) and decrease again once the Calvin–Benson cycle is activated. This quenching is sensitive to the balance between the electron transport rate and its associated proton transfer toward the thylakoid lumen on the one hand and the rate of ATP synthesis and the associated release of protons from the thylakoid lumen on the other hand. This form of quenching (corresponding to qE quenching, see Question 15) relaxes quickly as soon as electron transport stops, e.g., as soon as the light is turned off (see e.g., Nilkens et al. ). Other processes contributing to NPQ have slower induction kinetics (see Questions 2.3 and 15) whose induction (e.g., photoinhibition) depends as well on light intensity. Higher non-photochemical quenching values related to higher values of qE under steady state conditions suggest a stronger imbalance between photosynthetic electron transport and the utilization of NADPH (reflected by lower qP values) (see e.g., Walters and Horton ). Under continuous and/or extreme stress, non-photochemical quenching can attain low values. This may in part be due to a loss of RCs. Photoinhibited PSII RCs lose their variable fluorescence, and as a consequence, this variable fluorescence can then no longer be quenched, which means less NPQ (Schansker and Van Rensen ). Low values may also be caused by decreased rates of linear electron transport generating a smaller transthylakoid proton gradient or to an increased permeability of the membrane due to lipid peroxidation caused by oxygen radicals, which will also reduce the build up of a ΔpH over the membrane.
Deviations from the NPQ induction kinetics have been described in some green algae, where the NPQ induction capacity varies strongly depending on the species (see e.g., Bonente et al. ). For example, in Ulva laetevirens, NPQ was induced with an early peak within the first minute of exposure to high light, followed by a decrease and a subsequent rise (Bonente et al. ).
Question 21. Which assumptions are made when interpreting fluorescence transient measurements?
Both the quenching analysis and the JIP test (see Questions 15 and 19 for a discussion) are based on assumptions that were commonly made in the 1990s (e.g., van Kooten and Snel for the quenching analysis, Strasser for the JIP test and see also Stirbet and Govindjee for a list of assumptions). The most important assumption is that the fluorescence increase from F O to F M reflects mainly the reduction of Q A. This idea was first put forward by Duysens and Sweers. However, this assumption was challenged almost from the beginning (see e.g., Delosme ). Delosme proposed the existence of two processes determining the fluorescence rise. His suggestion that the redox state of the PQ-pool could play a role (Delosme ) led to the idea that the Q B-site occupancy state was the second factor (see Samson et al. ); an idea that was extended further by Schansker et al. who suggested that the Q B-site occupancy state controlled the re-oxidation rate of Q A− and who proposed on the basis of this idea that in the presence of Q A− further excitations could induce conformational changes in the PSII RCs which would then cause an increase of the fluorescence yield. Considering the occupancy state idea, Schreiber proposed that the thermal phase might be explained by a reduction of the inactive branch of PSII. Vredenberg and co-workers (Vredenberg; Vredenberg et al. ) developed another interpretation model, in which, in addition to Q A−, the IP phase is determined by the electric field, and JI rise reflects an inactivation of PSII RCs (associated with proton transport over the membrane) in which Pheo− can accumulate. These alternative interpretations were challenged by Stirbet and Govindjee. The first assumption that the F O-to-F M rise is a reflection of the reduction of Q A implies that it should always be possible to reach F M, since all Q A can be reduced if the light intensity is high enough (i.e., when the excitation rate is much higher than re-oxidation rate of Q A− by forward electron transport and/or the exchange of PQH2 for PQ at the Q B-site). However, Schreiber, Samson and Bruce and Schansker et al. showed in several ways that this is not the case.
A second, related, assumption is that there are no changes in non-photochemical quenching during a saturating pulse. Finally, a third assumption is that the parameters F V/F M and ΦPSII are measures of the PSII quantum yield and that ΦPSII can be used to calculate the photosynthetic electron transport rate. For ΦPSII, this assumption has been partially verified experimentally, showing under several conditions a linear correlation between the calculated photosynthetic electron transport rate and the CO2 assimilation rate (Genty et al.; Krall and Edwards and see Questions 29 and 30). We note that the meaning of the parameter F V/F M has not been derived experimentally but is based on an analysis of so-called competitive rate equations (fluorescence emission competes with other processes like heat emission and photosynthesis) for the F O and F M states (Kitajima and Butler; Kramer et al. ). This analysis is correct as long as the fluorescence rise between F O and F M is determined by the reduction of Q A only (see Schansker et al. for a discussion of this point).
Question 22. Are there naturally occurring fluorescence quenchers other than QA?
Another fluorescence quencher that has been described extensively is P680+ (Butler; Zankel; Shinkarev and Govindjee; Steffen et al. ). The short lifetime of P680+ keeps the population of this quencher low under most conditions. Simulation work has shown that under high light conditions, the highest concentration should occur around the J-step (Lazár ), which was supported by experimental observations (Schansker et al. ). However, P680+ quenching does not affect the F O and F M levels. Oxidized PQ molecules can also quench fluorescence, but only in isolated thylakoids and in PSII-enriched membranes (Vernotte et al.; Kurreck et al.; Tóth et al. ) and not in leaves (Tóth et al. ). Other quenchers such as Car+ and Chl+ have been proposed and shown to play a role at temperatures below 100 K (Schweitzer and Brudvig ) in the case of ChlZ+, an accessory chlorophyll molecule in the RC of PSII, or to have a very short lifetime at room temperature (Steffen et al. ) in the case of Car+. Neither of these quenchers seems to play a role in the fluorescence measurements discussed in this paper.
Question 23. What is the difference between fluorescence emission spectra recorded at 77 K and those recorded at room temperature?
In Question 2 Sect. 4, measurements of 77 K fluorescence emission spectra were introduced as a method to study PSII and PSI antennae. The recording of fluorescence emission spectra is much easier at room temperature. In this case, one dominant peak at ~684 nm is recorded, which is attributed principally to fluorescence emission by the PSII-core complex (including the core antennae CP47 and CP43) and further a shoulder at 710–740 nm corresponding to several fluorescence emission sources—particularly PSI-LHCI and several minor PSII bands (Fig. 8) (Franck et al.; Krausz et al.; Pancaldi et al. ). When the temperature is lowered, the 684 nm band is replaced by two bands, peaking at 685 and 695 nm, respectively; bands that in first instance were shown to be associated with the PSII core (Gasanov et al.; Rijgersberg et al. ). The 695 nm band is due to fluorescence emission from CP47, whereas the 685 nm has been associated with fluorescence emission by CP43 [(Nakatani et al.; for spectroscopic analyses of CP47 and CP43: see Alfonso et al. (for both); van Dorssen et al. (CP47); Groot et al. (CP43)]. Srivastava et al. showed with an experiment on greening of peas how the 695 nm band increases in intensity as the PSII antenna size increases. In other words, despite CP47 being the source of the 695 nm emission, it is sensitive to the number of LHCII subunits bound to PSII. The relationship between the antenna size of PSII and the amplitude of the 695 nm band is further strengthened by the observation that chloroplast samples frozen in the presence of a ΔpH show a quenching of the 695 nm band (Krause et al. ). Based on a comparative study of photosynthetic mutants of Chlamydomonas reinhardtii, a relationship between LHCII-PSII association and emission intensity at ~695 nm has also been proposed at room temperature (Ferroni et al. ). To detect fluorescence emitted by LHCII itself as an individual peak at 680 nm, it is necessary to freeze the sample further to 4 K (see Govindjee ). However, a more or less distinct shoulder at 680 nm is often reported also at 77 K and attributed to the free LHCII trimers not linked with PSII in a stable association (Hemelrijk et al.; Siffel and Braunova; van der Weij-de Wit et al.; Pantaleoni et al.; Ferroni et al. ). At room temperature, the emission region around 680 nm, never visible as an individual peak in the spectrum, was also assigned to a contribution by free LHCII (Ferroni et al. ). Strasser and Butler showed that the strong band at 730 nm at 77 K is in part caused by energy transfer from PSII to PSI. Weis demonstrated that the absorption of PSII fluorescence emission by PSI can be reduced considerably using diluted “leaf powder” instead of whole leaf fragments. When using liquid samples, such as microalgae suspensions or isolated thylakoids, the PSI re-absorption of emitted light can be reduced by an adequate dilution of the sample. The re-absorption phenomenon also affects room temperature spectra, resulting in a relative increase in the emission at 710–740 nm and in a red shift of PSII emission (Franck et al. ).
Room temperature fluorescence emission spectra are not frequently used for photosynthesis studies, because the spectral components are not as well characterized as the 77 K spectra are (Franck et al.; Ferroni et al. ). However, methods have been developed to resolve at room temperature the contribution of PSII and PSI to Chl a fluorescence under F O, F M, and steady state conditions (F t) (Franck et al., ). Figure 8 gives examples of two such applications. Room temperature fluorescence spectra have also been used to evaluate the response of photosynthetic organisms (microalgae and in higher plants) to some environmental stresses (Romanowska-Duda et al.,; Ferroni et al.; Baldisserotto et al.,; Burling et al.; Hunsche et al. ). Finally, such spectra have been used as well to characterize developmental aspects of the photosynthetic membrane (Pancaldi et al.; Baldisserotto et al.; Ferroni et al., ) and, as discussed in Question 25, to estimate leaf chlorophyll content.
Question 24. Are the fluorescence rise kinetics sensitive to the chlorophyll content of the leaf?
For dilute solutions of chlorophyll molecules, the measured fluorescence intensity is proportional to the quantum yield of fluorescence multiplied by the number of photons absorbed and the chlorophyll concentration (Lakowicz ). On this basis, one would expect that the fluorescence intensity emitted by a leaf depends on the chlorophyll content of that leaf. However, as described under Question 4, the leaf is complex in optical terms, and it is difficult to predict if this physical law is really critical in determining the relationship between the chlorophyll content of the leaf and the fluorescence emission. Several experimental studies have addressed this question. Hsu and Leu showed that two leaves placed on top of each other emitted more Chl a fluorescence than a single leaf. However, this is a quite artificial construct, and it can easily be shown that the outcome of the experiment strongly depends on the way the leaves were oriented (e.g., both adaxial sides up, or adaxial side up for the top leaf and the abaxial side for the bottom leaf) (Ceppi and Schansker, unpublished observations, 2008). Sušila et al. attempted to show an effect of chlorophyll content using thylakoid suspensions differing in their chlorophyll content. Thylakoid suspensions are homogeneous in their properties, whereas under natural conditions, a change in the chlorophyll content will be accompanied by an adaptation (change in antenna sizes and/or changes in PSI:PSII ratio) of the individual chloroplasts inside the leaf to their new light environment (see Question 4). To address the effect of changes in the chlorophyll content of a leaf on the measured fluorescence properties, it is important to find a natural system in which the leaves can acclimate to the effects of the changing chlorophyll content. Sugar beet plants grown hydroponically in the absence of magnesium or low sulfate concentrations show a gradual loss of chlorophyll; the activity of the remaining ETCs remains largely unaffected, and there were no overall changes in the antenna size (effect on Chl a/b ratio was small). Under these conditions, an up to fivefold decrease in the chlorophyll content left the F O and F M values unchanged and had only a marginal effect on the fluorescence rise kinetics (Dinç et al. ). On the other hand, changes in the PSII antenna size did have an effect on the F M-intensity (Dinç et al. ). In conclusion, there is little indication that a stress-induced Chl loss in leaves would complicate the interpretation of Chl a fluorescence measurements.
Question 25. Can the leaf chlorophyll content be measured using fluorescence?
Chlorophyll fluorescence emission spectra can be used to determine the chlorophyll content of green plants (Buschmann ). The ratio between chlorophyll fluorescence at 735 nm and that at 700 nm (F735/F700) is linearly proportional to chlorophyll content (Gitelson et al. ). Conversely, as discussed in Question 24, the F M and F O values are not related to the chlorophyll content in leaves (Dinç et al. ). It may also be noted that there are simple chlorophyll meters on the market (CL-01, Hansatech Instruments, UK; SPAD meter, Minolta, Japan; CCM-200, Opti-Sciences, USA) that can be used to follow changes in the leaf chlorophyll content (see e.g., Cassol et al.; Dinç et al. ). These measurements can then be calibrated against measurements of the chlorophyll extracted from leaf areas measured before with the chlorophyll meter (see e.g., Dinç et al. ). Chl measurements on dark-adapted leaves seem to give more reproducible results than measurements made on light-adapted leaves (Ceppi and Schansker, unpublished data, 2008). If the chlorophyll meter is used over the day on the same leaf, the readings change (Mishra, unpublished data, 2010), e.g., due to chloroplast movements, which change the absorbance properties of the leaf (see Wada for a review on chloroplast movements). Chloroplasts are known to re-arrange themselves inside the cell in response to the ambient blue light intensity, adapting the absorbance properties of the leaf to the circumstances (Sakai et al.; Kasahara et al. ). This does not only affect chlorophyll meter measurements, but also normal fluorescence measurements (Brugnoli and Björkman ).
In practice, values measured using a Chl meter are often used as indicators for relative Chl changes. In that case, we assume that the measured values are a linear function of the leaf chlorophyll content between zero and the value measured on control leaves. However, in that case, it is important to test the validity of this assumption for each plant species and for each stress studied (Mishra, unpublished data, 2013).
Question 26. Is it possible to compare different leaves?
It is easy to take randomly two leaves from two plants of the same species and to make a fluorescence measurement. But is it truly possible to compare these two measurements? It is likely that a difference in maximum fluorescence amplitude will be observed. Especially, when studying OJIP transients, the kinetics are often more interesting than the absolute amplitude, and in that case, the difference in the fluorescence amplitude is eliminated by double normalization between F O and F M. Arithmetically, this is done in the following way: (F t − FO)/(F M − F O). The effect of this calculation is to rescale each fluorescence value in a range going from 0 (corresponding to F O) to 1 (corresponding to F M). For a comparison of the kinetics of the individual rise phases of the OJIP transient, the same approach can be used. To compare the kinetics of the OJ-rise, the measured transient can be double normalized between O and J [i.e., (F t − F O)/(F J − F O)]. In terms of nomenclature, double normalizations turn F values into so-called V values, like V J, which is the double normalized F J value (see Strasser et al. ).
An important source of variability between leaves is the development of stress symptoms. A common stress-related effect is chlorosis, and it has been argued that a change in the chlorophyll content of the leaf has an impact on the fluorescence kinetics and thereby invalidates the analysis (Hsu and Leu; Susila et al. ) but as discussed in Question 24, this is not the case as long as chloroplasts can adapt to their new light environment. In addition, if the development of the stress effects is followed over time, the gradually changing fluorescence properties will help the interpretation of the data.
A comparison of leaf fluorescence measurements on stressed and unstressed plants in the field is hampered by the fact that such leaves are often acclimated to completely different light environments. It is important to realize that growth light intensity affects the stoichiometries and composition of many components of the photosynthetic membrane like the PSII to PSI ratio, the LHCII to PSII ratio, and the amount of PSII-LHCII supercomplexes (e.g., Leong and Anderson,; Walters and Horton; Dietzel et al.; Wientjes et al. ). Therefore, it is of fundamental importance that the light environment (full sunlight, shade, deep shade) of leaves/plants to be compared has been adequately analyzed before the effect of a certain stress is addressed by fluorimetric techniques. Several papers illustrate this, e.g., stressed and unstressed plants were compared by van Heerden et al., whereas Zubek et al. compared leaves of plants with and without mycorrhiza, both ascribing the observed difference in the initial slope of the measured OJIP transients to an effect on the oxygen evolving complex of PSII. An alternative and more likely explanation—a difference in the effective antenna size between the samples due to differences in the growth light conditions—was not considered.
In summary, comparing leaves that develop under similar light conditions is relatively easy; however, comparing leaves that were growing under different light regimes is fraught with complications and should be avoided.
Question 27. Can measurements made with different instruments during a large-scale field survey be compared in absolute terms?
It is important to be aware that the use of different instruments, even from the same company and the same type, may yield different results in absolute terms. The light source used for saturating pulses of modulated instruments may age over time reducing its light intensity. The strength of the red LEDs of HandyPEAs often differs between instruments. When comparing measurements made with different types of instruments, differences may also be due to the specific geometry of the measuring cell or to the use of light sources emitting at different wavelengths. It is possible to reduce these differences by determining the light intensity dependence of the parameters of interest and using these data to change settings in order to obtain comparable results. Differences in wavelengths of the exciting light may be impossible to correct for. Green light for example has been shown to probe deeper in the leaves than red light; blue light is even more efficiently absorbed than red light (Terashima et al. ).
An example of the phenomenon, described above, is a study in which the same leaves were measured with different HandyPEA instruments (Bussotti et al. ) calibrated with identical settings (lamp intensity = 3,000 μmol photons m−2 s−1, time = 1 s, gain = 1). Both original and normalized transient curves were compared. Original curves differed consistently (both the extreme values of F O and F M showed a large range of variability), but the differences decreased consistently after normalization (double normalization between F O and F M—see Question 26 for a definition). The parameter F O/F M (parameter which is sensitive to changes in heat dissipation in the PSII antenna), as well as the normalized steps of OJIP transients—J and I (fluorescence intensities at 2–3 and 30 ms, respectively)—showed very little variability when comparing the measurements of the different instruments with a coefficient of variation (CV = SD/Mean) ranging from 3 to 5 %. The parameter PIabs, which consists of the product of a parameter sensitive to the effective antenna size, a parameter based on the maximum quantum yield of PSII, and a parameter sensitive to changes in the relative position of F J (see Question 19) showed a very high variability among instruments (PIabs showed a CV = 30 %; Bussotti et al. ). The high intrinsic variability of PIabs between instruments is due to the fact that this parameter is sensitive to the initial slope of the fluorescence rise and the relative position of the J-step, two factors that are both relatively sensitive to the light intensity of the beam. This high intrinsic variability makes the PIabs less useful for large, multi-instrument surveys.
In conclusion, in the case of small-scale experiments, it is always preferable to use the same instrument for all the measurements of an experiment.
Question 28. How should a sampling campaign be organized for an ecosystem?
Large-scale surveys should be carried out using a robust sampling design. Criteria and examples of such designs can be found in many statistical manuals and textbooks (see Elzinga et al. ). Here, we discuss some specific issues related to the assessment of fluorescence parameters.
Two problems widely discussed in the context of forest health monitoring (Luyssaert et al. ) and other ecosystems (Tuba et al. ) are intercalibration and harmonization. Here, “intercalibration” refers to procedures aimed at reducing the differences between instruments discussed in Question 27, and “harmonization” refers to the sampling strategy. The main issues are the variability of the leaf responses within the crown/canopy and the ecological scale of the investigation (assessment of the response of the whole tree/plant, or of a target population of leaves).
A complete representation of a plant should take into account the different levels, age, and position of leaves. This would be the approach of choice but would require a large number of samples, and this would be difficult to realize in large-scale sampling. Thus, normally only one or a few leaf positions (e.g., sun leaves in the upper part of the crown, south exposed leaves, flag leaves, or fully developed leaves) are considered, depending on the purpose of the survey.
The number of leaves to be sampled depends on the internal variability of the parameters of interest. The following formula can be used for this calculation:where n is the sample size; Z α is the standard normal coefficient (= 1.96 for a 95 % confidence level); s is the SD; B is the desired precision level expressed as percent of the mean value (Elzinga et al.; Gottardini et al. ). A recent study of boreal forests (Pollastrini et al. ) found that, in the higher external part of a crown of Betula pendula, the CV among different leaves was very low for F V/F M (1.6 %), and increased for the parameters related to the step J (1 − V J, CV = 7 %) and the step I (ΔV IP = 1 − V I, CV = 14 %). We mention here that this type of studies demonstrated that the IP phase, linked to the PSI content (Oukarroum et al.; Ceppi et al. ), is quite sensitive to different types of stress; e.g., it decreased in response to ozone (Bussotti et al. ) and nitrogen deprivation (Nikiforou and Manetas ), while it increased in response to high light conditions (Desotgiu et al. ).
In order to sample as many leaves as possible during a single day, sampling must be performed during the whole day and cannot be limited to specific hours. As a consequence, leaves are sampled under different conditions of short-term light acclimation and different extents of photoinhibition. To reduce the associated variability, it is necessary to allow the regulatory mechanisms induced by the ambient light to relax and to allow the leaves to recover from photoinhibition, which means a sufficient period of at least 4–5 h of dark acclimation at a constant temperature must be made before measurement. In addition, to avoid the onset of leaf senescence or the induction of other stress factors that can change the physiological state of the leaf during sampling and dark acclimation of the leaves, all fieldwork must be performed as fast as possible. Managing a large number of samples in a short time, e.g., 1,000 samples in one day, requires fast instruments/experimental protocols. OJIP transients need less than 1 s of illumination, and their analysis is best suited for this kind of application.
Question 29. What additional information can be obtained from simultaneous measurements of CO2 exchange and chlorophyll fluorescence?
Modern Infrared gas analyzers (IRGAs; such as the CIRAS-3, PP Systems and LI-COR 6400) allow gas exchange and fluorescence to be measured simultaneously. This combination can provide information about effects on the photosynthetic ETC, Calvin–Benson cycle activity, and diffusional limitations at the same time. Additionally, it is possible to determine chlorophyll fluorescence parameters under particular conditions (e.g., increasing CO2 concentrations or low O2 concentrations) to determine the maximum electron transport rate. In this way, effects of a certain treatment can be more precisely assigned to a particular process in the whole photosynthetic apparatus than the use of these techniques individually would allow (see e.g., Laisk and Loreto; Laisk et al. ).
Three potential applications for simultaneous measurements have been proposed in the literature: Analysis of alternative sinks of electrons (e.g., Flexas et al.; Bota et al. ). Discrepancies between the electron transport rate (ETR) and the net CO2 assimilation rate (A n) are an indicator of the existence of alternative electron sinks. For example, an increased ETR/A n ratio indicates the existence of other electron sinks (e.g., Mehler reaction, photorespiration, nitrate reduction) in competition with CO2 assimilation (e.g., Bota et al. ). An important cause for an increase in ETR/A n is photorespiration (e.g., Galmés et al. ). Comparing measurements made at 2 % O2 (suppression of photorespiration) with measurements made at 21 % O2 (ambient) allows a quantification of this process (Rosenqvist and van Kooten ). Calculation of CO 2 diffusion resistance/conductance in the mesophyll, which in bifacial leaves is formed by the palisade and spongiform tissues (von Caemmerer ). Mesophyll conductance is an important variable controlling CO2 diffusion to the carboxylation site of Rubisco. Several methods have been proposed to estimate mesophyll conductance in leaves (for a detailed description of these methods, see e.g., Warren; Flexas et. al. ). One of these methods is based on IRGA measurements (measurements of CO2 assimilation, A n/C i curves) and the electron transport rate from chlorophyll fluorescence (e.g., Flexas et al. )—a detailed description of this method is available elsewhere (Loreto et al.; Evans and Loreto; Flexas et al. ). Sink limitations in photosynthesis (Rosenqvist and van Kooten ). In a variation of point (i) above, simultaneous IRGA and chlorophyll fluorescence measurements made at low (2 % O2, which suppresses photorespiration in C3 plants), and ambient (21 % O2) oxygen concentrations can be used to estimate changes in source–sink relationships in leaves (Rosenqvist and van Kooten ). Under non-sink restrictions and 2 % oxygen, the CO2 assimilation rate (A n) should increase, and the ETR should remain the same. By contrast, if the leaf is sink-limited, lowering the oxygen concentration to 2 % will not affect A n, whereas the ETR will decrease (down-regulation by final product).
Analysis of alternative sinks of electrons (e.g., Flexas et al.; Bota et al. ). Discrepancies between the electron transport rate (ETR) and the net CO2 assimilation rate (A n) are an indicator of the existence of alternative electron sinks. For example, an increased ETR/A n ratio indicates the existence of other electron sinks (e.g., Mehler reaction, photorespiration, nitrate reduction) in competition with CO2 assimilation (e.g., Bota et al. ). An important cause for an increase in ETR/A n is photorespiration (e.g., Galmés et al. ). Comparing measurements made at 2 % O2 (suppression of photorespiration) with measurements made at 21 % O2 (ambient) allows a quantification of this process (Rosenqvist and van Kooten ).
Calculation of CO 2 diffusion resistance/conductance in the mesophyll, which in bifacial leaves is formed by the palisade and spongiform tissues (von Caemmerer ). Mesophyll conductance is an important variable controlling CO2 diffusion to the carboxylation site of Rubisco. Several methods have been proposed to estimate mesophyll conductance in leaves (for a detailed description of these methods, see e.g., Warren; Flexas et. al. ). One of these methods is based on IRGA measurements (measurements of CO2 assimilation, A n/C i curves) and the electron transport rate from chlorophyll fluorescence (e.g., Flexas et al. )—a detailed description of this method is available elsewhere (Loreto et al.; Evans and Loreto; Flexas et al. ).
Sink limitations in photosynthesis (Rosenqvist and van Kooten ). In a variation of point (i) above, simultaneous IRGA and chlorophyll fluorescence measurements made at low (2 % O2, which suppresses photorespiration in C3 plants), and ambient (21 % O2) oxygen concentrations can be used to estimate changes in source–sink relationships in leaves (Rosenqvist and van Kooten ). Under non-sink restrictions and 2 % oxygen, the CO2 assimilation rate (A n) should increase, and the ETR should remain the same. By contrast, if the leaf is sink-limited, lowering the oxygen concentration to 2 % will not affect A n, whereas the ETR will decrease (down-regulation by final product).
Question 30. Can the wavelength dependence of the quantum yield for CO2 fixation be predicted by measuring chlorophyll fluorescence?
Emerson and Lewis observed that the quantum yield for O2 evolution is wavelength dependent and that it dropped off quickly at wavelengths longer than 700 nm. Similar wavelength dependence is observed for Φco2 (McCree; Inada; Hogewoning et al. ). Typically, photosynthetic rates are higher when a leaf is illuminated with light in the red region (600–680 nm), compared with an equal number of photons in the blue or the green regions of the light spectrum. Beyond 700 nm (i.e., the FR region), Φco2 declines rapidly to nearly zero at about 730 nm.
Genty et al. demonstrated that the PSII operating efficiency (i.e., F q′/F M′ or Φ PSII) correlates linearly with Φco2 if the photosynthetic steady state is induced by white light of different intensities, while photorespiratory activity is low. This is always the case in C4 plants and in C3 plants, this occurs when the O2 concentration is low (1–2 %) (see also Question 29; Genty et al.; Krall and Edwards ). In contrast to the relationship between Φco2 and light intensity, Chl a fluorescence measurements are unsuitable for the estimation of the relationship between Φco2 and the wavelength of irradiance used. To understand why, it is important to consider the factors that may affect the wavelength dependence of both Φco2 and Φ PSII.
First, different wavelengths are not reflected and transmitted to the same extent by leaves. Hence, the fraction of light absorbed by a leaf is wavelength dependent (e.g., Vogelmann and Han; see also Question 4). This also explains why most leaves are green and not, for example, black—relatively more green light is reflected and transmitted than red and blue light, and therefore, the fraction of red and blue light absorbed by a leaf is higher than the fraction of green light that is absorbed (Terashima et al. ). A lower fraction of incident light reaching the photosystems will directly result in a loss of Φco2 on an incident light basis. However, at low light intensities in the linear part of the light-response curve, there are no limitations for the electron flow on the acceptor side of PSII. Therefore, within a range of low light intensities (typically between PPFD of 0 and 50 µmol photons m−2 s−1, or an even narrower range for shade-leaves), Φ PSII does not necessarily change as a result of small changes in the light intensity. Beyond this range of low light intensities, Φ PSII decreases when the light intensity increases, due to limitations for the electron flow on the acceptor side of PSII (see Question 2 Sect. 1 for electron transfer rates on the acceptor side of PSII). Thus, wavelength-dependent differences in the fraction of incident light reaching the photosystems are reflected by differences in Φco2, but at low light intensities not necessarily by differences in Φ PSII.
Second, carotenoids differ in the efficiency (35–90 %) with which they transfer excitation energy to chlorophylls, whereas the chlorophyll to chlorophyll energy transfer efficiency in antenna complexes is nearly 100 % (Croce et al.; de Weerd et al.,; Caffarri et al. ). The transfer efficiency of carotenoids depends on their chemical structure and position within the photosynthetic apparatus. Carotenoids have absorption maxima in the blue and green regions, and therefore, blue light is used less efficiently by the photosystems than e.g., red light. Wavelength-dependent differences in the fraction of light absorbed by carotenoids affect the fraction of absorbed light reaching the RCs of the photosystems. This leads to the same argument as in the previous paragraph, i.e., this effect decreases Φco2 but at low light intensities does not necessarily decrease Φ PSII.
Third, leaves contain non-photosynthetic pigments such as flavonoids and free carotenoids. These pigments predominantly absorb light in the UV region but also in the blue and green part of the spectrum. These non-photosynthetic pigments are not connected to the photosystems and do not transfer the absorbed energy to the photosynthetic apparatus (see Question 31 for a discussion of these compounds and their detection). The absorption of light by non-photosynthetic pigments will reduce the fraction of the incident light reaching the photosystems especially in the blue and to a smaller extent in the green. Again this will affect Φco2 at these wavelengths but at low light intensities not necessarily Φ PSII.
Finally, the pigment composition and absorbance properties of PSI and PSII differ, and therefore, the balance of excitation between the two photosystems is wavelength dependent for a given state of the photosynthetic apparatus (e.g., Evans; Chow et al.,; Melis; Walters and Horton; Hogewoning et al. ). In practice, when light within a narrow-band wavelength range is used to illuminate a white-light acclimated leaf, one of the two photosystems is often excited more strongly than the other. Any imbalance in excitation between the two photosystems results in a loss of Φco2. This wavelength dependence is especially clear in the FR region. FR light still quite efficiently excites PSI but is very inefficiently absorbed by PSII (see Question 16). This is called “the red drop” and, as noted above, this leads to a rapid decline of ΦO2 and consequently of Φco2 as well at wavelengths longer than 685 nm. Obviously, when PSI is excited strongly by FR light, but PSII is excited only very weakly, electron flow from PSII to PSI is not restricted, and therefore, Φ PSII will be high. However, due to the inefficient absorption of the FR photons by PSII, linear electron flow is low, and therefore, Φco2 is low for FR light. On the other hand, if PSII is excited more strongly than PSI, the consequent loss of Φ PSII is reflected by a proportional loss of Φco2. Wavelengths in the range around 480 nm (blue) result in the strongest preferential excitation of PSII and therefore the strongest loss of both Φco2 and Φ PSII (Hogewoning et al. ). However, Φ PSII is also an unreliable measure of Φco2 for these blue wavelengths, due to the absorption by carotenoids and non-photosynthetic pigments (see above).
In summary, Φ PSII calculated from chlorophyll a fluorescence measurements is an unsuitable parameter for estimating the wavelength dependence of Φco2. Wavelength-dependent changes in (1) the absorbed light fraction, (2) the light fraction absorbed by photosynthetic carotenoids, and (3) the light fraction absorbed by non-photosynthetic pigments, directly affect the fraction of photons reaching the photosystems and therefore Φco2. However, at low light intensities, changes in the fraction of photons reaching the photosystems may not affect Φ PSII. Furthermore, (4) some wavelengths preferentially excite PSI, resulting in high Φ PSII values but low Φco2 values. As a consequence, for a reliable measurement of the wavelength dependence of Φco2, gas exchange measurements remain the gold standard.
Question 31. Can anthocyanins and flavonols be detected by chlorophyll fluorescence?
In vivo non-destructive determination of anthocyanins and flavonols in green parts of plants can be made using the fluorescence excitation ratio method (FER) (Bilger et al.; Agati et al. ). The FER method is based on the measurement of chlorophyll fluorescence induced by different excitation wavelengths. The extent of absorbance of light by the epidermal polyphenols can be derived on the basis of the ratio of chlorophyll fluorescence emission intensities induced by a standard red beam and a UV–VIS beam (wavelengths strongly absorbed by epidermal polyphenols). The role of different anthocyanins and flavonols can be distinguished by choosing appropriate wavelengths based on the specific absorbance spectra of the different anthocyanins and flavonols.
The chlorophyll fluorescence excitation technique was originally developed to assess UV-absorbing compounds in the leaf epidermis (Bilger et al. ). Ounis et al. extended the method developing remote sensing equipment (dual excitation FLIDAR) to study polyphenols not only in leaves but also in canopies of trees. This method has also been used for the determination of the presence of flavonoids, including anthocyanins, in the skins of fruits like grapes (Kolb at al. ), apples (Hagen et al. ), and olives (Agati et al. ). Betemps et al. showed that in fruits, the anthocyanins and other flavonoids localized in the outer skin layers reduce the chlorophyll fluorescence signal in proportion to the concentration of these polyphenols.
Pfündel et al. investigated two different types of commercial portable UV fluorometers for in vivo screening of anthocyanins and carotenoids in leaves. The UV-A-PAM fluorometer (Walz, Germany) makes use of a blue reference beam, whereas the Dualex fluorometer (FORCE-A, France) makes use of a red reference beam. For measurements on green leaves, the two instruments gave similar results, whereas the anthocyanins common in fruits absorbed part of the blue light of the UV-A-PAM reference beam which led, for fruits, to higher estimates for epidermal UV transmittance compared to that by the Dualex fluorometer. Pfündel et al. also noted that the absence of Chl b (e.g., in the barley chlorina f2 mutant) affected the determination of the polyphenols. Ben Ghozlen et al. developed and described an improved instrument, which they called the Multiplex (FORCE-A, France). It contains four light-emitting diodes (LEDs): UV-A (370 nm), blue (460 nm), green (515 nm), and red (637 nm) and three diodes to detect fluorescence emission at 590, 685, and 735 nm. The three diodes allow corrections for differences in the chlorophyll content of the sample. The red LED provides the reference beam, because it corresponds to a wavelength not absorbed by anthocyanins or flavonols. The fluorescence induced at this wavelength is compared with the fluorescence intensity induced by the excitation wavelength specific for the polyphenol of interest (e.g., green 515 nm light for anthocyanins or 370 nm UV-A light for flavonols). Ben Ghozlen et al. derived formulas to correlate these ratios with the actual polyphenol content of the sample.
In summary, a fluorescence-based method and accompanying equipment have been developed to determine the anthocyanin and flavonol content of leaves and fruits. In the case of fruits, the choice of the color (blue or red) of the reference beam influences the results, something that does not affect leaf measurements.
Question 32. Can Chl a fluorescence be used as an indicator for a specific stress in plants?
To use Chl a fluorescence as a tool to identify a specific stress, the effects of that stress on the photosynthetic apparatus must be understood (Kalaji et al., ). If heat stress destroys the donor side of part of the PSII RCs, it reduces the electron donation capacity of all PSII RCs together and, as a consequence, causes a slow down of the JI rise as measured by a PEA-type instrument (Srivastava et al. and see also Schreiber and Neubauer ). It also changes the recombination properties of the affected PSII RCs when measuring DF (Čajánek et al. ). In extreme cases, when all or nearly all PSII donor sides have been destroyed, the fluorescence rise levels off after ~300 μs of illumination (i.e., one charge separation) and then declines; this fluorescence pattern is called the K-peak (Guissé et al.; Srivastava et al.; Lazár et al. ). UV radiation may also destroy the donor side of PSII (e.g., Ohnishi et al.; Hakala et al. ), but, at the same time, may have additional affects on the PSII RC (e.g., Vass et al. ) and, thereby, on the fluorescence kinetics. For both drought stress and sulfate deficiency, it was shown that they affect PSI (Oukarroum et al.; Ceppi et al. ). Again, a combination of experimental phenomena is needed to distinguish these stress conditions. Another complication is that the PSII to PSI ratio that affects the parameter ΔV IP is regulated by the growth light intensity and quality as well (Leong and Anderson; Lee and Whitmarsh; Chow et al., ). Finally, there are considerable kinetic differences between the OJIP transients obtained from different plant species (Kirova et al. ). This means that good references are needed to determine if something is a stress effect, taking into account the normal plasticity of the OJIP transients. The available physiological studies often concentrate on the effects of severe stress under laboratory conditions. In the field, milder stress effects are often observed, which possibly have to be distinguished from other sources of variability, so that additional research efforts will be needed to obtain reliable “fingerprints” for a particular stress. An example of the type of research needed is a study by Kalaji who characterized the effects of 16 abiotic stresses on the fluorescence properties of two Syrian landraces (cvs. Arabi Abiad and Arabi Aswad) of barley (see also Kalaji and Guo ).
Another approach is to make mathematical analyses of sets of OJIP transients in combination with DF and 820 nm transmission transients. Goltsev et al. trained an artificial neural network to estimate the relative water content (RWC) of leaves; they obtained a correlation value of R 2 = 0.98 between the estimated RWC value and the gravimetrically determined RWC value of the analyzed leaves.
In France, commercial software was developed that compares measured OJIP transients with a database of fluorescence transients measured on plants of dozens of genotypes of agricultural and horticultural crops suffering from deficiencies of the following elements: N, Fe, Mn, Mg, P, S, Ca, and B. This approach has similarities with the one discussed above, but it is more ambitious in its scope. This software is at the moment very popular among farmers, especially in Poland, Ukraine, and Russia, where it is promoted by producers of fertilizer. Kalaji et al. (unpublished data, 2013) did many experiments to test the software and suggested analysis, comparing the fluorescence analysis with the chemical analysis of several plant species grown under different conditions of nutrient deficiency. These studies suggested that this method needs further improvements to achieve a general validity.
For the moment, it is not possible to identify specific stresses using Chl a fluorescence. As noted above, different stresses may have similar effects on the photosynthetic system. In addition, in the field, plants are often subjected to several stresses at the same time, e.g., a combination of drought, high light, and heat stress. In the laboratory, it is possible to induce clear symptoms, whereas in the field, a combination of a less severe stress and acclimation may cause less specific symptoms. In other words, the complicated relationship between fluorescence kinetics, stress, and natural variation is not yet sufficiently well understood to use fluorescence measurements as fingerprints for specific stresses under natural conditions.
Question 33. Is Chl a fluorescence a useful tool for the monitoring of aquatic ecosystems?
The use of Chl a fluorescence measurements for the study of aquatic environments is a topic by itself, and here only a few points are made. This topic was reviewed in depth in a recent book edited by Suggett et al..
The estimation of biomass production in aquatic environments is one of the research topics in which fluorescence techniques have played a major role and for which special equipment was developed. Falkowski and Kolber developed a submersible pump-probe instrument (see Question 2 Sect. 1 for the principle) to study biomass productivity profiles along the water column in the ocean. Further, Kolber et al. discussed a new fluorescence approach, which they called the FRR approach which was originally developed for aquatic studies. Instead of continuous light, subsaturating excitation flashes (of which the spacing can be varied) are used to induce photosynthesis. With these flashlets, the authors could create STFs as well as multiple turnover pulses and, at the same time, study the dark relaxation kinetics of fluorescence. One of the parameters that could be determined was the effective PSII antenna cross section. Using a Xenon-PAM (Walz, Germany), Geel et al. studied several classes of aquatic organisms in order to derive the oxygen evolution activity of these organisms on the basis of fluorescence measurements. Kromkamp and Forster have reviewed such studies.
Another important difference between measurements on plants and measurements in an aquatic environment is that aquatic samples often consist of a mixture of photosynthetic organisms. To cope with this problem, several instruments were developed that make use of differences in the pigment composition of different classes of photosynthetic organisms. Schreiber has described an instrument built by Kolbowski and Schreiber called the PHYTO-PAM Phytoplankton analyzer (Walz, Germany). The instrument does not use a monochromatic modulated beam but excites the samples alternately with weak 10 μs light pulses of 470, 535, 620, and 650 nm (inducing F O) to distinguish between cyanobacteria, green algae, and diatoms. Deconvolution of the algal composition was possible using reference spectra derived from pure cultures of particular classes of organisms. In addition, the instrument allowed the estimation of the activity of these classes of organisms using saturating light pulses (see Questions 2.3, 10, and 15).
Beutler et al. built a submergible instrument called bbe FluoroprobeTM (Moldaenke, Germany) that made use of five excitation wavelengths (450, 525, 570, 590, and 610 nm) with which particular accessory pigments can be relatively specifically excited allowing the detection of peridinin containing dinoflagellates and Pyrrophyta, chlorophyll b containing green algae, fucoxanthin containing diatoms, and zeaxanthin as well as phycobiliprotein containing cyanobacteria or cryptophycaea. Reference spectra were used to determine the chlorophyll content associated with each class. Rolland et al. using this equipment for a monitoring study of the Marne reservoir summarize its application in monitoring studies up till that time and note that it can be used down to 100 m, and that it has a short response time.
Further, Schreiber et al. have developed a new Multi-Color-PAM (Walz, Germany) instrument that combines multi-spectral excitation (400, 440, 480, 540, 590, and 625 nm) with the possibility to measure fast fluorescence kinetics as well as the absorption cross section of PSII antennae.
Photosynthetic aquatic organisms (including aquatic plants such as Spirodela) in combination with fluorescence measurements can also be used to monitor the presence of pesticides, heavy metals, and natural compounds that affect the photosynthetic apparatus. Snel et al. using a modulated PAM fluorometer and monitoring ETR followed the effect of low concentrations of linuron in microcosm experiments. Another example of the application of a PAM fluorometer was published by Perreault et al. who evaluated the effect of copper oxide nanoparticles on Lemna gibba using among other things the quenching analysis. Srivastava et al. using a PEA instrument showed that the cyanobacterial toxin fischerellin A caused an increase of F J; this indicates that fischerellin A affects the acceptor side of PSII like DCMU does. Bueno et al. showed an effect of lindane on the cyanobacterium Anabaena; they observed that this pesticide initially affects the amplitude of the JIP phase and after longer incubation times (12–24 h) causes a general suppression of the fluorescence intensity. In other studies, the effects of heavy metals like cadmium (Romanowska-Duda et al. ) or chromate (Susplugas et al. ) on Spirodela oligorrhiza have been studied. Finally, Chl a fluorescence is also a useful tool for the study of hydrogen production in e.g., Chlamydomonas reinhardtii (see e.g., Antal et al. )
Concluding remarks
For anyone who is beginning to use Chl a fluorescence, the overwhelming number of studies that already has been carried out may make it difficult to quickly discover what is already known and which experiments will add something new to the literature. Even so, it is important to formulate first some questions that are worth answering. Two points are worth keeping in mind. In the first place, the “flash,” “pulse,” and “steady state” communities live often in parallel universes; as a consequence, there are still many opportunities for a more integrated use of these techniques. In the second place, the currently available fluorescence devices can do much more than the few standard protocols that are most frequently used.
As this educational review suggests, there are many aspects of fluorescence that can be studied with different devices best adapted for the study of these different aspects. Flash experiments can be used to study the electron transfer reactions within PSII, direct fluorescence measurements are best for the measurement of the OJIP transients, which follow the reduction of the photosynthetic electron chain, and modulated measurements are best for steady state photosynthesis and the study of light-induced regulatory mechanisms affecting the antenna of PSII. The power of fluorescence techniques can be increased considerably by simultaneously measuring other parameters, such as 820 nm transmittance changes (probing PSI) or CO2 assimilation.
There are only a few basic principles that determine the yield of fluorescence. However, due to the fact that it is sensitive to many processes that differ between photosynthetic organisms, light acclimation states, intactness of samples, and stress conditions, a myriad of responses has been documented in the literature. The fluorescence literature may often be confusing and contradictory, but it contains a wealth of data and observations that we all need to understand. Only in that way, the wealth of information generated by past fluorescence research can be maximally exploited.
The contributing authors are available to be contacted by researchers for further discussions on the application of Chl a fluorescence through the following website: https://groups.google.com/forum/?hl=en#!forum/chlorophyllfluorescence where they will provide regular feedback.
References 360
- 1.
Agati G, Pinelli P, Cortés Ebner S, Romani A, Cartelat A, Cerovic ZG. Nondestructive evaluation of anthocyanins in olive (Olea europaea) fruits by in situ chlorophyll fluorescence spectroscopy. J Agric Food Chem. 2005;53:1354-1363.
Not in our library10.1021/jf048381d
- 2.
Agati G, Cerovic ZG, Pinelli P, Tattini M. Light-induced accumulation of ortho-dihydroxylated flavonoids as non-destructively monitored by chlorophyll fluorescence excitation techniques. Environ Exp Bot. 2011;73:3-9.
Not in our library
- 3.
Alfonso M, Montoya G, Cases R, Rodriguez R, Picorel R. Core Antenna complexes, CP43 and CP47, of higher plant photosystem II. Spectral properties, pigment stoichiometry, and amino acid composition. Biochemistry. 1994;33:10494-10500.
Not in our library10.1021/bi00200a034
- 4.
Antal TK, Volgusheva AA, Kukarskih GP, Bulychev AA, Krendeleva TE, Rubin AB. Effects of sulfur limitation on photosystem II functioning in Chlamydomonas reinhardtii as probed by chlorophyll a fluorescence. Physiol Plant. 2006;128:360-367.
Not in our library
- 5.
Baker NR. Chlorophyll fluorescence: a probe of photosynthesis in vivo. Annu Rev Plant Biol. 2008;59:89-113.
Not in our library10.1146/annurev.arplant.59.032607.092759
- 6.
Balachandran S, Osmond CB, Daley PF. Diagnosis of the earliest strain–specific interactions between tobacco mosaic virus and chloroplasts of tobacco leaves in vivo by means of chlorophyll fluorescence imaging. Plant Physiol. 1994;104:1059-1065.
Not in our library10.1104/pp.104.3.1059
- 7.
Baldisserotto C, Ferroni L, Moro I, Fasulo MP, Pancaldi S. Modulations of the thylakoid system in snow xanthophycean alga cultured in the dark for two months: comparison between microspectrofluorimetric responses and morphological aspects. Protoplasma. 2005;226:125-135.
Not in our library10.1007/s00709-005-0127-1
- 8.
Baldisserotto C, Ferroni L, Zanzi C, Marchesini R, Pagnoni A, Pancaldi S. Morpho-physiologcal and biochemical responses in the floating lamina of Trapa natans exposed to molybdenum. Protoplasma. 2010;240:83-97.
Not in our library10.1007/s00709-009-0094-z
- 9.
Baldisserotto C, Ferroni L, Giovanardi M, Boccaletti L, Pantaleoni L, Pancaldi S. Salinity promotes growth of freshwater Neochloris oleoabundans UTEX 1185 (Sphaeropleales, Chlorophyta): morphological aspects. Phycologia. 2012;51:700-710.
Not in our library
- 10.
Baldisserotto C, Ferroni L, Pantaleoni L, Pancaldi S (2013) Comparison of photosynthesis recovery dynamics in floating leaves of Trapa natans after inhibition by manganese or molybdenum: effects on photosystem II. Plant Physiol Biochem 70:387–395
Not in our library10.1016/j.plaphy.2013.05.044
- 11.
Ballottari M, Girardon J, Dall’Osto L, Bassi R. Evolution and functional properties of photosystem II light harvesting complexes in eukaryotes. Biochim Biophys Acta. 2012;1817:143-157.
Not in our library10.1016/j.bbabio.2011.06.005
- 12.
Bannister TT, Rice G. Parallel time courses of oxygen evolution and chlorophyll fluorescence. Biochim Biophys Acta. 1968;162:555-580.
Not in our library10.1016/0005-2728(68)90063-7
- 13.
Beardall J, Quigg A, Raven JA, Larkum AW, Douglas SE, Raven JA. Oxygen consumption: photorespiration and chlororespiration. Photosynthesis in algae. 2003;157-181.
Not in our library
- 14.
Bellafiore S, Barneche F, Peltier G, Rochaix J-D. State transitions and light adaptation require chloroplast thylakoid protein kinase STN7. Nature. 2005;433:892-895.
Not in our library10.1038/nature03286
- 15.
Ben Ghozlen N, Cerovic ZG, Germain C, Toutain S, Latouche G. Non-destructive optical monitoring of grape maturation by proximal sensing. Sensors. 2010;10:10040-10068.
Not in our library10.3390/s101110040
- 16.
Bennoun P. Evidence for a respiratory chain in the chloroplast. Proc Natl Acad Sci USA. 1982;79:4352-4356.
Not in our library10.1073/pnas.79.14.4352
- 17.
Bennoun P. The present model for chlororespiration. Photosynth Res. 2002;73:273-277.
Not in our library10.1023/a:1020479920622
- 18.
Berera R, van Grondelle R, Kennis JTM. Ultrafast transient absorption spectroscopy: principles and application tot photosynthetic systems. Photosynth Res. 2009;101:105-118.
Not in our library10.1007/s11120-009-9454-y
- 19.
Betemps DL, Fachinello JC, Galarca SP, Portela NM, Remorini D, Massai R, Agati G. Non-destructive evaluation of ripening and quality traits in apples using a multiparametric fluorescence sensor. J Sci Food Agric. 2011;92:1855-1864.
Not in our library10.1002/jsfa.5552
- 20.
Beutler M, Wiltshire KH, Meyer B, Moldaenke C, Lüring C, Meyerhöfer M, Hansen U-P, Dau H. A fluorometric method for the differentiation of algal populations in vivo and in situ. Photosynth Res. 2002;72:39-53.
Not in our library10.1023/a:1016026607048
- 21.
Bilger W, Björkman O. Role of the xanthophylls cycle in photoprotection elucidated by measurements of light-induced absorbance changes, fluorescence and photosynthesis in leaves of Hedera canariensis. Photosynth Res. 1990;25:173-185.
Not in our library10.1007/bf00033159
- 22.
Bilger W, Björkman O. Temperature dependence of violaxanthin de-epoxidation and non-photochemical fluorescence quenching in intact leaves of Gossypium hirsutum L. and Malva parviflora L. Planta. 1991;184:226-234.
Not in our library10.1007/bf00197951
- 23.
Bilger W, Schreiber U. Energy-dependent quenching of dark-level chlorophyll fluorescence in intact leaves. Photosynth Res. 1986;10:303-308.
Not in our library10.1007/bf00118295
- 24.
Bilger W, Veit M, Schreiber L, Schreiber U. Measurement of leaf epidermal transmittance of UV radiation by chlorophyll fluorescence. Physiol Plant. 1997;101:754-763.
Not in our library
- 25.
Björkman O, Demmig B. Photon yield of O2 evolution and chlorophyll fluorescence characteristics at 77 K among vascular plants of diverse origins. Planta. 1987;170:489-504.
Not in our library10.1007/bf00402983
- 26.
Boisvert S, Joly D, Carpentier R. Quantitative analysis of the experimental O–J–I–P chlorophyll fluorescence induction kinetics: apparent activation energy and origin of each step. FEBS J. 2006;273:4770-4777.
Not in our library10.1111/j.1742-4658.2006.05475.x
- 27.
Bonente G, Passarini F, Cazzaniga S, Mancone C, Buia MC, Tripodi M, Bassi R, Caffarri S. The occurrence of the psbS gene product in Chlamydomonas reinhardtii and in other photosynthetic organisms and its correlation with energy quenching. Photochem Photobiol. 2008;84:1359-1370.
Not in our library10.1111/j.1751-1097.2008.00456.x
- 28.
Bonora A, Pancaldi S, Gualandri R, Fasulo MP. Carotenoid and ultrastructure variations in plastids of Arum italicum Miller fruit during maturation and ripening. J Exp Bot. 2000;51:873-884.
Not in our library
- 29.
Bota J, Medrano H, Flexas J. Is photosynthesis limited by decreased Rubisco activity and RuBP content under progressive water stress? New Phytol. 2004;162:671-681.
Not in our library10.1111/j.1469-8137.2004.01056.x
- 30.
Bradbury M, Baker NR. Analysis of the slow phases of the in vivo chlorophyll fluorescence induction curve. Changes in the redox state of photosystem II electron acceptors and fluorescence emission from photosystems I and II. Biochim Biophys Acta. 1981;635:542-551.
Not in our library10.1016/0005-2728(81)90113-4
- 31.
Brestic M, Zivcak M, Rout GR, Das AB. PSII fluorescence techniques for measurement of drought and high temperature stress signal in crop plants: protocols and applications. Molecular stress physiology of plants. 2013;87-131.
Not in our library
- 32.
Brugnoli E, Björkman O. Chloroplast movements in leaves: influence on chlorophyll fluorescence and measurements of light-induced absorbance changes related to ΔpH and zeaxanthin formation. Photosynth Res. 1992;32:23-35.
Not in our library10.1007/bf00028795
- 33.
Buchanan BB. The ferredoxin/thioredoxin system: a key element in the regulatory function of light in photosynthesis. BioScience. 1984;34:378-383.
Not in our library
- 34.
Bueno M, Fillat MF, Strasser RJ, Maldonado-Rodriguez R, Marina N, Smienk H, Gómez-Moreno C, Barja F. Effects of lindane on the photosynthetic apparatus of the cyanobacterium Anabaena. Environ Sci Pollut Res. 2004;11:98-106.
Not in our library10.1007/bf02979709
- 35.
Bukhov NG, Govindachary S, Egorova EA, Joly D, Carpentier R. N, N, N′, N′-tetramethyl-p-phenylenediamine initiates the appearance of a well resolved I peak in the kinetics of the fluorescence rise in isolated thylakoids. Biochim Biophys Acta. 2003;1607:91-96.
Not in our library10.1016/j.bbabio.2003.09.002
- 36.
Burling K, Hunsche M, Noga G. Use of blue-green and chlorophyll fluorescence measurements for differentiation between nitrogen deficiency and pathogen infection in winter wheat. J Plant Physiol. 2011;168:1641-1648.
Not in our library10.1016/j.jplph.2011.03.016
- 37.
Burrows PA, Sazonov LA, Svab Z, Maliga P, Nixon P. Identification of a functional respiratory complex in chloroplasts through analysis of tobacco mutants containing disrupted plastid ndh genes. EMBO J. 1998;17:868-876.
Not in our library10.1093/emboj/17.4.868
- 38.
Buschmann C. Photochemical and non-photochemical quenching coefficients of the chlorophyll fluorescence: comparison of variation and limits. Photosynthetica. 1999;37:217-224.
Not in our library
- 39.
Buschmann C. Variability and application of the chlorophyll fluorescence emission ratio red/far-red of leaves. Photosynth Res. 2007;92:261-271.
Not in our library10.1007/s11120-007-9187-8
- 40.
Buschmann C, Langsdorf G, Lichtenthaler HK. Imaging of the blue, green, and red fluorescence emissionof plants: an overview. Photosynthetica. 2001;38:483-491.
Not in our library
Cited by papers we hold 6
- Complex Response of the Chlorarachniophyte <named-content content-type="genus-species">Bigelowiella natans</named-content> to Iron Availability · 2021Not checked
- Effects of Arbuscular Mycorrhizal Fungi on Rice Growth Under Different Flooding and Shading Regimes · 2021Not checked
- Chlorophyll Fluorescence, Photoinhibition and Abiotic Stress: Does it Make Any Difference the Fact to Be a C3 or C4 Species? · 2019No notice
- Nitrogen starvation-induced cellular crosstalk of ROS-scavenging antioxidants and phytohormone enhanced the biofuel potential of green microalga Acutodesmus dimorphus · 2017No notice
- Impact of Metal and Metal Oxide Nanoparticles on Plant: A Critical Review · 2017No notice
- Frequently asked questions about chlorophyll fluorescence, the sequel · 2016Corrected
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.