No retraction, correction or concern found when last checked on Oct 27, 2026.
Scanner invariant representations for diffusion MRI harmonization
Daniel Moyer, Greg Ver Steeg, Chantal M. W. Tax and 1 more
Magnetic Resonance in Medicine · 2020 · CC BY
Abstract
Purpose. In the present work, we describe the correction of diffusion‐weighted MRI for site and scanner biases using a novel method based on invariant representation.
Theory and Methods. Pooled imaging data from multiple sources are subject to variation between the sources. Correcting for these biases has become very important as imaging studies increase in size and multi‐site cases become more common. We propose learning an intermediate representation invariant to site/protocol variables, a technique adapted from information theory‐based algorithmic fairness; by leveraging the data processing inequality, such a representation can then be used to create an image reconstruction that is uninformative of its original source, yet still faithful to underlying structures. To implement this, we use a deep learning method based on variational auto‐encoders (VAE) to construct scanner invariant encodings of the imaging data.
Results. To evaluate our method, we use training data from the 2018 MICCAI Computational Diffusion MRI (CDMRI) Challenge Harmonization dataset. Our proposed method shows improvements on independent test data relative to a recently published baseline method on each subtask, mapping data from three different scanning contexts to and from one separate target scanning context.
Conclusions. As imaging studies continue to grow, the use of pooled multi‐site imaging will similarly increase. Invariant representation presents a strong candidate for the harmonization of these data.
Full text
Its licence does not allow us to show the full text. Read it at PubMed Central:
Read at PubMed CentralReferences 53
- 1.
Chen J, Liu J, Calhoun VD, et al. Exploration of scanning effects in multi‐site structural MRI studies. J Neurosci Methods. 2014;230:37–50.
Not in our library10.1016/j.jneumeth.2014.04.023
- 2.
Fortin JP, Parker D, Tunc B, et al. Harmonization of multi‐site diffusion tensor imaging data. Neuroimage. 2017;161:149–170.
Not in our library10.1016/j.neuroimage.2017.08.047
- 3.
Jovicich J, Czanner S, Greve D, et al. Reliability in multi‐site structural MRI studies: effects of gradient non‐linearity correction on phantom and human data. Neuroimage. 2006;30:436–443.
Not in our library10.1016/j.neuroimage.2005.09.046
- 4.
Hawco C, Viviano JD, Chavez S, et al. A longitudinal human phantom reliability study of multi‐center T1‐weighted, DTI, and resting state fMRI data. Psychiatry Res‐Neuroim. 2018;282:134–142.
Not in our library10.1016/j.pscychresns.2018.06.004
- 5.
- 6.
Magnotta VA, Matsui JT, Liu D, et al. Multicenter reliability of diffusion tensor imaging. Brain Connectivity. 2012;2:345–355.
Not in our library10.1089/brain.2012.0112
- 7.
Zavaliangos‐Petropulu A, Nir TM, Thomopoulos SI, et al. Diffusion MRI indices and their relation to cognitive impairment in brain aging: the updated multi‐protocol approach in ADNI3. Front Neuroinform. 2019;13:2.
Not in our library10.3389/fninf.2019.00002
- 8.
Correia MM, Carpenter TA, Williams GB. Looking for the optimal DTI acquisition scheme given a maximum scan time: are more b‐values a waste of time? Magn Reson Imaging. 2009;27:163–175.
Not in our library10.1016/j.mri.2008.06.011
- 9.
Giannelli M, Cosottini M, Michelassi MC, et al. Dependence of brain DTI maps of fractional anisotropy and mean diffusivity on the number of diffusion weighting directions. J Appl Clin Med Phys. 2010;11:176–190.
Not in our library10.1120/jacmp.v11i1.2927
- 10.
Pagani E, Hirsch JG, Pouwels PJ, et al. Intercenter differences in diffusion tensor MRI acquisition. J Magn Reson Imaging. 2010;31:1458–1468.
Not in our library10.1002/jmri.22186
- 11.
Papinutto ND, Maule F, Jovicich J. Reproducibility and biases in high field brain diffusion MRI: an evaluation of acquisition and analysis variables. Magn Reson Imaging. 2013;31:827–839.
Not in our library10.1016/j.mri.2013.03.004
- 12.
- 13.
White T, Magnotta VA, Bockholt HJ, et al. Global white matter abnormalities in schizophrenia: a multisite diffusion tensor imaging study. Schizophrenia Bull. 2009;37:222–232.
Not in our library10.1093/schbul/sbp088
- 14.
Zhan L, Leow AD, Jahanshad N, et al. How does angular resolution affect diffusion imaging measures? Neuroimage. 2010;49:1357–1371.
Not in our library10.1016/j.neuroimage.2009.09.057
- 15.
Zhan L, Mueller BA, Jahanshad N, et al. Magnetic resonance field strength effects on diffusion measures and brain connectivity networks. Brain Connectivity. 2013;3:72–86.
Not in our library10.1089/brain.2012.0114
- 16.
Zhan L, Franc D, Patel V, et al. How do spatial and angular resolution affect brain connectivity maps from diffusion MRI? In: 2012 9th IEEE International Symposium on Biomedical Imaging (ISBI). Barcelona, Spain: IEEE; 2012:1–4.
Not in our library10.1109/isbi.2012.6235469
- 17.
Blumberg SB, Tanno R, Kokkinos I, Alexander DC. Deeper image quality transfer: training low‐memory neural networks for 3D images In: MICCAI. Granada, Spain: Springer; 2018 118–125.
Not in our library
- 18.
Tanno R, Worrall DE, Ghosh A, et al. Bayesian image quality transfer with CNNs: exploring uncertainty in dMRI super‐resolution In: MICCAI. Quebec City, Canada: Springer; 2017;611–619.
Not in our library
- 19.
Mirzaalian H, Ning L, Savadjiev P. Multi‐site harmonization of diffusion MRI data in a registration framework. Brain Imaging Behavior. 2018;12:284–295.
Not in our library10.1007/s11682-016-9670-y
- 20.
Ning L, Bonet‐Carne E, Grussu F, et al. Multi‐shell diffusion MRI harmonisation and enhancement challenge (MUSHAC): progress and results In: International Conference on Medical Image Computing and Computer‐Assisted Intervention. Granada, Spain: Springer; 2018;217–224.
Not in our library
- 21.
Tax CM, Grussu F, Kaden E, et al. Cross‐vendor and cross‐protocol harmonisation of diffusion MRI data: a comparative study In: Proceedings of the International Society for Magnetic Resonance in Medicine. Paris. 2018;471.
Not in our library
- 22.
Zhu AH, Moyer DC, Nir TM, Thompson PM, Jahanshad N. Challenges and opportunities in dMRI data harmonization In: International Conference on Medical Image Computing and Computer‐Assisted Intervention. Granada, Spain: Springer; 2018:157–172.
Not in our library
- 23.
Johnson WE, Li C, Rabinovic A. Adjusting batch effects in microarray expression data using empirical Bayes methods. Biostatistics. 2007;8:118–127.
Not in our library10.1093/biostatistics/kxj037
- 24.
Mirzaalian H, de Pierrefeu A, Savadjiev P, et al. Harmonizing diffusion MRI data across multiple sites and scanners In: MICCAI. Munich, Germany: Springer; 2015;12–19.
Not in our library10.1007/978-3-319-24553-9_2
- 25.
Mirzaalian H, Ning L, Savadjiev P. Inter‐site and inter‐scanner diffusion MRI data harmonization. Neuroimage. 2016;135:311–323.
Not in our library10.1016/j.neuroimage.2016.04.041
- 26.
Karayumak SC, Bouix S, Ning L, et al. Retrospective harmonization of multi‐site diffusion MRI data acquired with different acquisition parameters. Neuroimage. 2019;184:180–200.
Not in our library10.1016/j.neuroimage.2018.08.073
- 27.
Karayumak SC, Kubicki M, Rathi Y. Harmonizing diffusion MRI data across magnetic field strengths In: International Conference on Medical Image Computing and Computer‐Assisted Intervention. Granada, Spain: Springer; 2018;116–124.
Not in our library
- 28.
Koppers S, Bloy L, Berman JI, Tax CM, Edgar JC, Merhof D. Spherical harmonic residual network for diffusion signal harmonization. 2018; arXiv preprint arXiv:1808.01595
Not in our library
- 29.
Cover TM, Thomas JA. Elements of Information Theory. Hoboken, NJ: John Wiley & Sons; 2012.
Not in our library
- 30.
Moyer D, Gao S, Brekelmans R, Galstyan A, Ver Steeg G. Invariant representations without adversarial training In: Advances in Neural Information Processing Systems. Montreal, Canada: Curran Associates, Inc.; 2018;31:9102–9111.
Not in our library
- 31.
Kingma DP, Welling M. Auto‐encoding variational Bayes. 2013; arXiv preprint arXiv:1312.6114.
Not in our library
- 32.
Higgins I, Matthey L, Pal A, et al. beta‐VAE: learning basic visual concepts with a constrained variational framework. ICLR. 2017;2:6.
Not in our library
- 33.
Goodfellow I, Bengio Y, Courville A. Deep Learning. Cambridge, MA: MIT Press; 2016.
Not in our library
- 34.
Rumelhart DE, Hinton GE, Williams RJ. Learning internal representations by error propagation. Technical Report, California Univ San Diego La Jolla Inst for Cognitive Science; 1985.
Not in our library
- 35.
Kingma, DP, Ba J. Adam: a method for stochastic optimization. 2014; arXiv preprint arXiv:1412.6980.
Not in our library
- 36.
Tax CM, Grussu F, Kaden E, et al. Cross‐scanner and cross‐protocol diffusion mri data harmonisation: a benchmark database and evaluation of algorithms. Neuroimage. 2019;195:285–299.
Not in our library10.1016/j.neuroimage.2019.01.077
- 37.
Andersson JL, Skare S, Ashburner J. How to correct susceptibility distortions in spin‐echo echo‐planar images: application to diffusion tensor imaging. Neuroimage. 2003;20:870–888.
Not in our library10.1016/s1053-8119(03)00336-7
- 38.
- 39.
Glasser MF, Sotiropoulos SN, Wilson JA, et al. The minimal preprocessing pipelines for the Human Connectome Project. Neuroimage. 2013;80:105–124.
Not in our library10.1016/j.neuroimage.2013.04.127
- 40.
Rudrapatna S, Parker G, Roberts J, Jones D. Can we correct for interactions between subject motion and gradient‐nonlinearity in diffusion MRI. In: Proceedings of the International Society for Magnetic Resonance in Medicine, Paris, France; 2018;1206.
Not in our library
- 41.
Assaf Y, Pasternak O. Diffusion tensor imaging (DTI)‐based white matter mapping in brain research: a review. J Mol Neurosci. 2008;34:51–61.
Not in our library10.1007/s12031-007-0029-0
- 42.
Jeurissen B, Tournier JD, Dhollander T, Connelly A, Sijbers J. Multi‐tissue constrained spherical deconvolution for improved analysis of multi‐shell diffusion MRI data. NeuroImage. 2014;103:411–426.
Not in our library10.1016/j.neuroimage.2014.07.061
- 43.
Dhollander T, Raffelt D, Connelly A. Unsupervised 3‐tissue response function estimation from single‐shell or multi‐shell diffusion MR data without a co‐registered T1 image. In: ISMRM Workshop on Breaking the Barriers of Diffusion MRI, Singapore; 2016:5.
Not in our library
- 44.
Tournier JD, Smith R, Raffelt D, et al. Mrtrix3: a fast, flexible and open software framework for medical image processing and visualisation. NeuroImage. 2019:116137.
Not in our library10.1016/j.neuroimage.2019.116137
- 45.
Jensen JH, Helpern JA, Ramani A, Lu H, Kaczynski K. Diffusional kurtosis imaging: the quantification of non‐Gaussian water diffusion by means of magnetic resonance imaging. Magn Reson Med. 2005;53:1432–1440.
Not in our library10.1002/mrm.20508
- 46.
Özarslan E, Koay CG, Shepherd TM, et al. Mean apparent propagator (MAP) MRI: a novel diffusion imaging method for mapping tissue microstructure. NeuroImage. 2013;78:16–32.
Not in our library10.1016/j.neuroimage.2013.04.016
- 47.
Ning L, Bonet‐Carne E, Grussu F, et al. Cross‐scanner and cross‐protocol harmonisation of multi‐shell diffusion MRI data: open challenge and evaluation results In: Proceedings of the International Society for Magnetic Resonance in Medicine, Montreal, Canada; 2019.
Not in our library
- 48.
Armstrong JS, Collopy F. Error measures for generalizing about forecasting methods: empirical comparisons. Int J Forecasting. 1992;8:69–80.
Not in our library
- 49.
Makridakis S. Accuracy measures: theoretical and practical concerns. Int J Forecasting. 1993;9:527–529.
Not in our library
- 50.
Abdi H. Coefficient of variation. Encyclopedia Res Design. 2010;1:169–171.
Not in our library
- 51.
Cercignani M, Bammer R, Sormani MP, Fazekas F, Filippi M. Inter‐sequence and inter‐imaging unit variability of diffusion tensor MR imaging histogram‐derived metrics of the brain in healthy volunteers. Am J Neuroradiol. 2003;24:638–643.
Not in our library
- 52.
Sotiropoulos SN, Jbabdi S, Xu J, et al. Advances in diffusion MRI acquisition and processing in the human connectome project. Neuroimage. 2013;80:125–143.
Not in our library10.1016/j.neuroimage.2013.05.057
- 53.
Jespersen SN, Kroenke CD, Østergaard L, Ackerman JJ, Yablonskiy DA. Modeling dendrite density from magnetic resonance diffusion measurements. Neuroimage. 2007;34:1473–1486.
Not in our library10.1016/j.neuroimage.2006.10.037
Cited by papers we hold 3
- Image harmonization: A review of statistical and deep learning methods for removing batch effects and evaluation metrics for effective harmonization · 2023No notice
- Making Radiomics More Reproducible across Scanner and Imaging Protocol Variations: A Review of Harmonization Methods · 2021No notice
- Deep learning-based unlearning of dataset bias for MRI harmonisation and confound removal · 2021No notice
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.