Improved bone bonding of hydroxyapatite spacers with a high porosity in a quantitative computed tomography‐image pixel analysis: A prospective 1‐year comparative study of the consecutive cohort undergoing double‐door cervical laminoplasty
Yoshiki Takeoka, Takashi Yurube, Koichiro Maeno and 11 more
JOR Spine · 2020
doi:10.1002/jsp2.1080 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Abstract Laminoplasty using hydroxyapatite (HA) spacers is widely performed in patients with cervical myelopathy. However, spacer dislocation is a critical complication caused by bone absorption and inadequate bone conductivity, and can result in dural damage and restenosis. We thus designed a prospective cohort study to clarify the feasibility of increased porosity HA spacers for double‐door laminoplasty by analyzing computed tomography (CT) images. Forty‐seven patients underwent cervical laminoplasty. Two different types of CERATITE HA spacer were used, either high porosity (50%) or low porosity (35%). These HA spacers were placed in an alternating manner into the laminae in each patient. In total, 85 high‐porosity (50%) HA spacers and 84 low‐porosity (35%) HA spacers were implanted. At postoperative 2 weeks, 3 months, 6 months, and 1 year, CT images were obtained. In both groups, the percentage of bone‐bonding boundary area of the HA spacer in contact with laminae and bone volume of the spinous process relative to the 2‐week value were calculated by a 3D and 2D CT‐image pixel analysis. The bone‐bonding ratio was significantly higher in high‐porosity (50%) than low‐porosity (35%) HA spacers at 3 months and thereafter (1 year, 69.3 ± 27.8% and 49.7 ± 32.9% respectively, P <.01). The bone volume in both groups significantly decreased with time (1 year, 73.2 ± 29.8% and 69.0 ± 30.4% respectively, P <.01), indicating bone absorption. This showed no significant difference between the HA spacers (P =.15) but was higher in high‐porosity (50%) than low‐porosity (35%) HA spacers throughout the study period. Meanwhile, spacer breakage was found in 4.7% of high‐porosity (50%) HA spacers and 1.2% of low‐porosity (35%) HA spacers (P =.37). In summary, high‐porosity (50%) HA spacers have the advantages of accelerated bone bonding and relatively decelerated bone absorption compared to low‐porosity (35%) HA spacers; however, possibly more frequent breakage of HA spacers with a high porosity (50%) requires careful, extended postoperative follow‐up.
Abstract licence: CC BY-NC
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.